White Rodgers 1F95EZ-0671 specifications Troubleshooting, Reset Operation

Page 8

TROUBLESHOOTING

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermo- stat by removing the wires from terminals RH and RC (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings, press the , and FAN button simultaneously. The thermo- stat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or system.

Tighten connections.

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when

 

 

may also be intermittent.

a lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set System to HEAT and raise the setpoint

 

 

thermostat requires replacement.

above room temperature. Within a few seconds the

 

 

 

thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the

 

 

 

room temperature. There may be up to a five minute delay

 

 

 

before the thermostat clicks in Cooling.

 

 

 

 

Heat, Cool or Fan

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Runs Constantly

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3.

Possible short in heat/cool/fan system.

under terminal block. Try resetting the thermostat as de-

 

4.

FAN Switch set to Fan ON.

scribed above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration

Disagree

 

 

Menu section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle

Cycles Too Fast or Too Slow

 

the size of the Heating System may

faster than older mechanical models. The system turns

(narrow or wide

 

be influencing the cycle rate.

on and off more frequently but runs for a shorter time

temperature swing)

 

 

so there is no increase in energy use. If you would like

 

 

 

an increased cycle time, choose SL for slow cycle in the

 

 

 

Configuration menu reference, steps 4 through 6. If an ac-

 

 

 

ceptable cycle rate is not achieved, contact a local HVAC

 

 

 

service person for additional suggestions.

 

 

 

 

Homeowner Help Line: 1-800-284-2925

White-Rodgers is a division of Emerson Electric Co.

The Emerson logo is a

www.white-rodgers.com

trademark and service mark

of Emerson Electric Co.

www.emersonclimate.com

Image 8
Contents Specifications ApplicationsSave these instructions for future use Model Programming Choices 1F95EZ-0671Installation Wiring ConnectionsWiring Diagrams Wire Spdt Heat Only Zone Valve WiringProgramming and Configuration Items Thermostat Quick ReferenceHome Screen Description Hold Copy Menu identifies buttonINSTALLER/CONFIGURATION Menu Be set in the range of 0 to 99 using or buttons Operating Your Thermostat Symptom Possible Cause Corrective Action TroubleshootingReset Operation
Related manuals
Manual 8 pages 1.34 Kb

1F95EZ-0671 specifications

The White Rodgers 1F95EZ-0671 is an advanced programmable thermostat designed to offer convenience and control over home heating and cooling systems. It is an ideal choice for homeowners looking to optimize their energy usage while maintaining comfortable living conditions.

One of the standout features of the 1F95EZ-0671 is its user-friendly interface, which includes a large, easy-to-read touchscreen display. The intuitive design allows users to navigate through settings effortlessly, making it accessible for individuals of all ages. The display is backlit, ensuring visibility even in low light conditions, which adds to its ease of use.

This thermostat supports both heating and cooling systems, including conventional systems as well as heat pumps, making it versatile for various home setups. Its compatibility with 24V systems further enhances its appeal for homeowners looking to upgrade their existing thermostats without extensive modifications.

Another significant technological advancement in the 1F95EZ-0671 is its Wi-Fi connectivity. This feature allows users to control their home climate remotely via a smartphone app, providing unparalleled convenience. Whether at work or on vacation, users can adjust their home temperature settings, ensuring optimal comfort upon their return. The app also enables users to monitor energy usage, helping them make informed decisions about their heating and cooling practices.

Energy efficiency is a key focus of the 1F95EZ-0671. It features a 7-day programmable schedule, allowing users to set heating and cooling times based on their specific routines. By programming temperature changes for different times of the day, users can significantly reduce energy consumption and lower utility bills. The thermostat also includes a vacation mode, which temporarily overrides the regular schedule, further optimizing energy savings when the home is unoccupied.

Additionally, the 1F95EZ-0671 is equipped with Smart Alerts that notify users of extreme temperatures, helping to prevent potential problems and ensure a safe home environment. With its combination of advanced features and user-centric design, the White Rodgers 1F95EZ-0671 provides an effective solution for modern temperature control, making it a valuable addition to any home.