INSTALLER/CONFIGURATION MENU
With Heat or A/C selected, press and hold the Menu button for at least 5 seconds. The display will show item #1 in the
table below. Press Menu to advance to the next menu item. Press or to change a menu item options.
INSTALLER/CONFIGURATION MENU
Menu | HP | SS | Press | Displayed | Press | or | to | Comments |
Ref. |
|
| Button | (Factory Default) | select from listed op- |
| ||
|
|
|
|
|
| tions |
|
|
1 | 1 | 1 | MENU | (MS 2) | HP 1, HP 2, SS 1 | Selects | ||
|
|
|
|
|
|
|
| Heat Pump 1 (HP 1, 1 compressor), |
|
|
|
|
|
|
|
| Heat Pump 2 (HP 2, 2 compressor or 2 speed |
|
|
|
|
|
|
|
| compressor), or Single Stage (SS 1) |
|
|
|
|
|
|
|
| |
2 | 2 | 2 | MENU | (GAS) for SS or MS | ELE or GAS |
| GAS setting: furnace controls the blower | |
|
|
|
| (ELE) for HP1, HP2 |
|
|
| ELE setting: thermostat controls the blower |
|
|
|
|
|
|
|
|
|
3 | 3 | 3 | MENU | (On) E |
| OFF |
| Selects Energy Management Recovery (EMR) |
|
|
|
|
|
|
|
| On or OFF. (Not available in |
|
|
|
|
|
|
|
| mable mode) |
4 | – | 4 | MENU | (ME) Cr Heat |
| SL, FA |
| Selects Adjustable Anticipation, cycle rate, Heat |
|
|
|
|
|
|
|
| (This item only appears when MS 2 or SS 1 is |
|
|
|
|
|
|
|
| selected above) |
5 | 4 | – | MENU | (ME) Cr Heat A/C |
| SL, FA |
| Selects Adjustable Compressor Anticipation |
|
|
|
|
|
|
|
| (Heat Pump) this item only appears when |
|
|
|
|
|
|
|
| HP 1, HP 2 is selected above |
6 | 5 | 5 | MENU | (ME) Cr A/C |
| SL, FA |
| Selects Adjustable Anticipation, cycle rate, cool |
|
|
|
| or |
|
|
| (when MS 2 or SS 1 is selected above) or |
|
|
|
| (FA) Cr Aux Heat |
| SL |
| Selects the cycle rate for Auxiliary stage (when |
|
|
|
|
|
|
|
| HP 1 or HP 2 is selected above) |
|
|
|
|
|
|
|
|
|
7 | 6 | 6 | MENU | (OFF) CL |
| On |
| Selects Compressor Lockout Off or On |
|
|
|
|
|
|
|
| |
8 | 7 | 7 | MENU | Heat A/C Off | Heat A/C Off, |
| System Mode Configuration | |
|
|
|
| or | Heat Off with Fan icon, |
| ||
|
|
|
| Aux Heat A/C Off | Heat Off without Fan icon |
| ||
|
|
|
|
|
| A/C Off |
|
|
|
|
|
|
|
|
|
|
|
9 | 8 | 8 | MENU | (OFF) CO |
| On |
| Selects Compressor Optimization |
|
|
|
|
|
|
|
|
|
10 | 9 | 9 | MENU | (On) dL |
| OFF |
| Selects Display Light On or OFF |
|
|
|
|
|
|
| ||
11 | 10 | 10 | MENU | 0 HI | 1 HI, 2 HI, 3HI, 4 HI, | Adjustable Ambient Temperature Display | ||
|
|
|
| (current temperature) | 1 LO, 2 LO, 3 LO, 4 LO |
| ||
|
|
|
|
|
|
|
|
|
12 | 11 | 11 | MENU | °F |
| °C |
| Selects Fahrenheit/Celsius Temperature Display |
|
|
|
| (current temperature) |
|
|
|
|
13 | 12 | 12 | MENU | (0) P |
| 7 |
| Defaults to P (0) |
|
|
|
|
|
|
|
| P (7) is |
|
|
|
|
|
|
|
|
|
14 | 13 | 13 | MENU | PS (2) |
| 4 |
| Selects Program periods per day: |
|
|
|
| Day, Night | Morn, Day, Eve, Night | 4 = Morn, Day, Eve, Night | ||
|
|
|
|
|
|
|
| 2 = Day, Night |
|
|
|
|
|
|
|
| (Skipped if |
15 | 14 | – | MENU | (On) Heat FA |
| OFF |
| Fast Heat option may be disabled by |
|
|
|
|
|
|
|
| selecting OFF. NA to SS or HP1 config. |
|
|
|
|
|
|
|
|
|
16 | 15 | 14 | MENU | (On) FA A/C |
| OFF |
| Fast Cool option may be disabled by |
|
|
|
|
|
|
|
| selecting OFF. NA to SS or HP1 config. |
|
|
|
|
|
|
|
|
|
17 | 16 | 15 | MENU | (On) dS |
| Off |
| Selects Automatic Daylight Saving Time option |
|
|
|
|
|
|
|
|
|
18 | 17 | 16 | MENU | (99) HL Heat |
| 62 to 98 |
| Select's Limited HEAT Range |
|
|
|
|
|
|
|
|
|
19 | 18 | 17 | MENU | (45) LL A/C |
| 46 to 82 |
| Select's Limited A/C Range |
|
|
|
|
|
|
|
|
|
20 | 19 | – | MENU | (0) dF |
| 1 to 9 |
| Selects dF (Dual Fuel) setting. 0 is Off |
|
|
|
|
|
|
|
| (If Dual Fuel option is required, a selection of 5 |
|
|
|
|
|
|
|
| is recommended) |
|
|
| MENU | (60) Cd |
| 0 to 99 |
| Selects compressor delay in seconds when dF |
|
|
|
|
|
|
|
| is greater than 0 |
21 | 20 | 18 | MENU | (o) A/C On |
| Heat (b) |
| Selects operation of the reversing valve terminal |
|
|
|
|
|
|
|
| (O/B) output as an O or B terminal |
22 | 21 | 19 | MENU |
|
|
|
| Returns to Normal Operation |
|
|
|
|
|
|
|
|
|
5