White Rodgers 1F95EZ-0671 specifications INSTALLER/CONFIGURATION Menu

Page 5

INSTALLER/CONFIGURATION MENU

With Heat or A/C selected, press and hold the Menu button for at least 5 seconds. The display will show item #1 in the

table below. Press Menu to advance to the next menu item. Press or to change a menu item options.

INSTALLER/CONFIGURATION MENU

Menu

HP

SS

Press

Displayed

Press

or

to

Comments

Ref.

 

 

Button

(Factory Default)

select from listed op-

 

 

 

 

 

 

 

tions

 

 

1

1

1

MENU

(MS 2)

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

 

 

 

 

 

 

 

 

Heat Pump 1 (HP 1, 1 compressor),

 

 

 

 

 

 

 

 

Heat Pump 2 (HP 2, 2 compressor or 2 speed

 

 

 

 

 

 

 

 

compressor), or Single Stage (SS 1)

 

 

 

 

 

 

 

 

2

2

2

MENU

(GAS) for SS or MS

ELE or GAS

 

GAS setting: furnace controls the blower

 

 

 

 

(ELE) for HP1, HP2

 

 

 

ELE setting: thermostat controls the blower

 

 

 

 

 

 

 

 

 

3

3

3

MENU

(On) E

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

On or OFF. (Not available in -non-program-

 

 

 

 

 

 

 

 

mable mode)

4

4

MENU

(ME) Cr Heat

 

SL, FA

 

Selects Adjustable Anticipation, cycle rate, Heat

 

 

 

 

 

 

 

 

(This item only appears when MS 2 or SS 1 is

 

 

 

 

 

 

 

 

selected above)

5

4

MENU

(ME) Cr Heat A/C

 

SL, FA

 

Selects Adjustable Compressor Anticipation

 

 

 

 

 

 

 

 

(Heat Pump) this item only appears when

 

 

 

 

 

 

 

 

HP 1, HP 2 is selected above

6

5

5

MENU

(ME) Cr A/C

 

SL, FA

 

Selects Adjustable Anticipation, cycle rate, cool

 

 

 

 

or

 

 

 

(when MS 2 or SS 1 is selected above) or

 

 

 

 

(FA) Cr Aux Heat

 

SL

 

Selects the cycle rate for Auxiliary stage (when

 

 

 

 

 

 

 

 

HP 1 or HP 2 is selected above)

 

 

 

 

 

 

 

 

 

7

6

6

MENU

(OFF) CL

 

On

 

Selects Compressor Lockout Off or On

 

 

 

 

 

 

 

 

8

7

7

MENU

Heat A/C Off

Heat A/C Off,

 

System Mode Configuration

 

 

 

 

or

Heat Off with Fan icon,

 

 

 

 

 

Aux Heat A/C Off

Heat Off without Fan icon

 

 

 

 

 

 

 

A/C Off

 

 

 

 

 

 

 

 

 

 

 

9

8

8

MENU

(OFF) CO

 

On

 

Selects Compressor Optimization

 

 

 

 

 

 

 

 

 

10

9

9

MENU

(On) dL

 

OFF

 

Selects Display Light On or OFF

 

 

 

 

 

 

 

11

10

10

MENU

0 HI

1 HI, 2 HI, 3HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

 

 

(current temperature)

1 LO, 2 LO, 3 LO, 4 LO

 

 

 

 

 

 

 

 

 

 

12

11

11

MENU

°F

 

°C

 

Selects Fahrenheit/Celsius Temperature Display

 

 

 

 

(current temperature)

 

 

 

 

13

12

12

MENU

(0) P

 

7

 

Defaults to P (0) non-programmable

 

 

 

 

 

 

 

 

P (7) is 7-day programming

 

 

 

 

 

 

 

 

 

14

13

13

MENU

PS (2)

 

4

 

Selects Program periods per day:

 

 

 

 

Day, Night

Morn, Day, Eve, Night

4 = Morn, Day, Eve, Night

 

 

 

 

 

 

 

 

2 = Day, Night

 

 

 

 

 

 

 

 

(Skipped if non-programmable)

15

14

MENU

(On) Heat FA

 

OFF

 

Fast Heat option may be disabled by

 

 

 

 

 

 

 

 

selecting OFF. NA to SS or HP1 config.

 

 

 

 

 

 

 

 

 

16

15

14

MENU

(On) FA A/C

 

OFF

 

Fast Cool option may be disabled by

 

 

 

 

 

 

 

 

selecting OFF. NA to SS or HP1 config.

 

 

 

 

 

 

 

 

 

17

16

15

MENU

(On) dS

 

Off

 

Selects Automatic Daylight Saving Time option

 

 

 

 

 

 

 

 

 

18

17

16

MENU

(99) HL Heat

 

62 to 98

 

Select's Limited HEAT Range

 

 

 

 

 

 

 

 

 

19

18

17

MENU

(45) LL A/C

 

46 to 82

 

Select's Limited A/C Range

 

 

 

 

 

 

 

 

 

20

19

MENU

(0) dF

 

1 to 9

 

Selects dF (Dual Fuel) setting. 0 is Off

 

 

 

 

 

 

 

 

(If Dual Fuel option is required, a selection of 5

 

 

 

 

 

 

 

 

is recommended)

 

 

 

MENU

(60) Cd

 

0 to 99

 

Selects compressor delay in seconds when dF

 

 

 

 

 

 

 

 

is greater than 0

21

20

18

MENU

(o) A/C On

 

Heat (b)

 

Selects operation of the reversing valve terminal

 

 

 

 

 

 

 

 

(O/B) output as an O or B terminal

22

21

19

MENU

 

 

 

 

Returns to Normal Operation

 

 

 

 

 

 

 

 

 

5

Image 5
Contents Applications SpecificationsSave these instructions for future use Model Programming Choices 1F95EZ-0671 Wiring Connections InstallationWire Spdt Heat Only Zone Valve Wiring Wiring DiagramsThermostat Quick Reference Programming and Configuration ItemsHome Screen Description Hold Copy Menu identifies buttonINSTALLER/CONFIGURATION Menu Be set in the range of 0 to 99 using or buttons Operating Your Thermostat Symptom Possible Cause Corrective Action TroubleshootingReset Operation
Related manuals