White Rodgers 1F95-0671 DS On Off Selects Automatic Daylight Saving Time option, Heat To L

Page 7

INSTALLER/CONFIGURATION MENU

21

20

18

MENU

dS (On)

Off

Selects Automatic Daylight Saving Time option

 

 

 

 

 

 

 

22

21

19

MENU

(OFF)

L, P, Limit

Selects one of 3 Keypad Lockout confi gurations

 

 

 

 

Keypad Lockout

 

L - Total Keypad Lockout

 

 

 

 

 

 

P - Partial Keypad Lockout

 

 

 

 

 

 

(Up and Keys still work)

 

 

 

 

 

 

Limit - Limited Temperature Range

 

 

 

 

 

 

 

 

 

 

MENU

(000)

1-999

Selects personal lockout code. 000 is NOT A

 

 

 

 

Keypad Lockout

 

VALID CODE.

 

 

 

 

 

 

 

23

22

20

MENU

L Heat

L 62 to L 98

Select Limited HEAT Range Temperature

 

 

 

 

(99)

 

 

 

 

 

 

 

 

 

24

23

21

MENU

L Cool

L 46 to L 82

Select Limited COOL Range Temperature

 

 

 

 

(45)

 

 

 

 

 

 

 

 

 

25

24

MENU

CO

06-50

Selects outdoor Compressor OFF temperature

 

 

 

 

(05)

 

(Balance Point temperature). 05 disables fea-

 

 

 

 

 

 

ture. Outdoor Remote required

 

 

 

 

 

 

 

 

 

 

MENU

(dF)

EA

Selects between dF (dual Fuel) or EA (Electric

 

 

 

 

 

 

Aux) only available if CO is greater than 05

 

 

 

 

 

 

 

 

 

 

MENU

Cd

 

Selects Compressor delay OFF time in seconds

 

 

 

 

(60)

 

(only if dF is selected)

 

 

 

 

 

 

 

26

25

MENU

AO

 

Selects AO (Auxiliary OFF) temperature. Fea-

 

 

 

 

(80)

 

ture disabled if 80 is selected. Outdoor Remote

 

 

 

 

 

 

required

 

 

 

 

 

 

 

27

26

22

MENU

Change Filter (OFF)

On

Selects Filter Change-out Indicator On or OFF.

 

 

 

 

 

 

 

 

 

 

MENU

Change Filter (200 h)

25-1975 h

Change Filter time in 25 hour increments. This

 

 

 

 

 

 

menu only appears if On is selected in above.

 

 

 

 

 

 

 

28

27

23

MENU

(OFF)

On

Selects UV Lamp

 

 

 

 

Change UV Lamp

 

Timer: On/OFF

 

 

 

 

 

 

 

 

 

 

MENU

(350)

25-1975

Selects number of Days between

 

 

 

 

Change UV Lamp

 

changing UV Lamp

 

 

 

 

 

 

 

29

28

24

MENU

Cool On (o)

Heat On (b)

Selects operation of the reversing valve terminal

 

 

 

 

 

 

(O/B) output as an O or B terminal

 

 

 

 

 

 

 

30

29

27

MENU

RUN SCHED

 

Returns to Normal Operation

 

 

 

 

 

 

 

1)This control can be configured for:

MS 2 – Multi-Stage System (no heat pump)

HP 1 – Heat Pump with one stage of compressor HP 2 – Heat Pump with two stage compressor or two

compressor system, Gas or Electric backup SS 1 – Single Stage System

2)GAS or Electric (ELE) fan operation. If the heating system requires the thermostat to energize the fan, select ELE. Select GAS if the heating system energizes the fan on a call for heat.

3)Select Cool Savings™ value – Selects the amount of adjustment for the Cool Savings™ feature in Cool mode with 1 (1°) being the least amount of adjustment and 6 (6°) being the most amount of adjustment. Default value is 3. Cool Savings is an optional energy saving feature that can reduce your cooling costs. It is based on the principal that lower indoor humidity makes a slightly higher tem- perature feel more comfortable. Cool Savings operates during periods of high demand which normally occur on the hottest summer days when a cooling system may run for hours to reach the thermostat setting. Long cooling run times also lower the indoor humidity. Cool Savings, very slowly, adjusts the setpoint temperature to make the setpoint closer to the displayed room temperature, to a maximum of the number of degrees you select. Adjust- ing the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off. The room temperature will actually be higher than the

thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature.

To turn this feature on in the Cool mode press Cool Savings. The display will show “Save” next to the set- point temperature. When Cool Savings is making adjust- ments to the room temperature display “Save” will be

ashing and the displayed room temperature may vary within the adjustment range you selected.

If "Save" is not displayed and this feature is OFF, no change will occur when the cooling system is continuously running during periods of high demand.

4)Energy Management Recovery: (this step is skipped if configured to be non-programmable).

Energy Management Recovery (E) On enables the ther- mostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start approximately 5 minutes early (15 minutes for heat pump) for every 1° of temperature required to reach setpoint.

Example: E On is selected and your heating is pro- grammed to 65° at night and 70° at 7 AM. If the building temperature is 65°, the difference between 65° and 70° is 5°. Allowing 5 minutes per degree, the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows approxi- mately 15 minutes per degree, because it takes longer to reach set temperature.

7

Image 7
Contents Applications SpecificationsSave these instructions for future use Power Stealing Switch InstallationInstalling New Thermostat Battery LocationTerminal Designation Description Wiring DiagramsHeat Pump Systems Home Screen Description Thermostat Quick ReferenceProgramming and Configuration Items INSTALLER/CONFIGURATION Menu Heat To L Selects AO Auxiliary OFF temperature. FeaTimer On/OFF DS On Off Selects Automatic Daylight Saving Time optionOr button Factory default is Loc On. You can make it Loc Off if youPress Menu after selecting the type of lockout Record the number you select for future useHeating System Operating Your ThermostatCheck Thermostat Operation Fan OperationProgramming Planning Your Program Important Energy Saving Factory Pre-ProgramWorksheet for Re-Programming 5+1+1 and 7 Day Program Enter the Cooling Program Automatic Daylight Saving CalculationProgramming Tip Copy Program Enter the Heating ProgramDual Fuel Temperature Setpoint Wired Remote Temperature SensingWeighing of Remote Reading Reset Operation TroubleshootingSymptom Possible Cause Corrective Action Page Homeowner Help Line

1F95-0671 specifications

The White Rodgers 1F95-0671 is a versatile and advanced programmable thermostat designed primarily for residential heating and cooling systems. This innovative device provides homeowners with the ability to manage their indoor climate efficiently while maximizing energy savings.

One of the standout features of the 1F95-0671 is its user-friendly interface, which includes a large, easily readable touchscreen display. This modern touch interface simplifies temperature adjustments and programming, making it accessible for users of all ages. The display features bright, clear graphics that provide real-time temperature readings, system status, and schedule reminders.

The thermostat offers a 7-day programmable schedule, allowing users to set different temperature profiles for each day of the week. This flexibility ensures that you'll be comfortable when you're home while saving energy by reducing heating and cooling when the house is empty. The 1F95-0671 also includes a copy feature, enabling users to quickly replicate settings from one day to another, making programming even more convenient.

Equipped with advanced technology, the White Rodgers 1F95-0671 is compatible with multi-stage heating and cooling systems, including gas, oil, electric, and heat pump systems. Its adaptive recovery feature learns how long it takes to reach the desired temperature and adjusts the start time accordingly, increasing overall comfort without wasting energy.

Another key characteristic of this thermostat is its ability to monitor indoor humidity levels. This feature is especially beneficial in regions with extreme weather, providing an added layer of comfort while optimizing HVAC system performance. Users can set humidity levels independently of temperature, enhancing overall home comfort.

Energy efficiency is further promoted through the inclusion of Energy Star ratings, helping users track their energy consumption. The thermostat's smart alerts notify users of maintenance reminders, such as filter changes or system service needs, ensuring HVAC systems operate at their peak performance.

Wireless connectivity is another significant advantage of the 1F95-0671, allowing users to control their home environment remotely using compatible mobile devices. This feature offers a level of convenience and control that aligns with the modern digital lifestyle, providing peace of mind whether at home or away.

In summary, the White Rodgers 1F95-0671 thermostat combines user-friendly functionality, advanced heating and cooling technologies, and energy-efficient performance, making it an excellent choice for homeowners looking to optimize their indoor climate. Its robust features and smart connectivity set it apart as a leading option in the programmable thermostat market.