If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermo- stat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer confi guration menu settings.

To reset the programming, clock and confi guration settings, press the or and SYSTEM button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or system.

Tighten connections.

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when

 

 

may also be intermittent.

a lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set SYSTEM Switch to HEAT and raise the

 

 

thermostat requires replacement.

setpoint above room temperature. Within a few seconds

 

 

 

the thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the

 

 

 

room temperature. There may be up to a fi ve minute delay

 

 

 

before the thermostat clicks in Cooling.

 

 

 

 

Heat, Cool or Fan

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Runs Constantly

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3.

Possible short in heat/cool/fan system.

under terminal block. Try resetting the thermostat as de-

 

4.

FAN Switch set to Fan ON.

scribed above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Confi guration

Disagree

 

 

Menu section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle

Cycles Too Fast or Too Slow

 

the size of the Heating System may

faster than older mechanical models. The system turns

(narrow or wide

 

be infl uencing the cycle rate.

on and off more frequently but runs for a shorter time

temperature swing)

 

 

so there is no increase in energy use. If you would like

 

 

 

an increased cycle time, choose SL for slow cycle in the

 

 

 

Confi guration menu, step 7 (heat) or 8 (cool). If an ac-

 

 

 

ceptable cycle rate is not achieved, contact a local HVAC

 

 

 

service person for additional suggestions.

 

 

 

 

Forgot Keypad

 

 

Press the menu button (button will disappear) and hold in

Lockout Code

 

 

for 20 seconds. This unlocks the thermostat.

 

 

 

 

14

Image 14
Contents Save these instructions for future use SpecificationsApplications Battery Location InstallationInstalling New Thermostat Power Stealing SwitchWiring Diagrams Terminal Designation DescriptionHeat Pump Systems Programming and Configuration Items Thermostat Quick ReferenceHome Screen Description INSTALLER/CONFIGURATION Menu DS On Off Selects Automatic Daylight Saving Time option Selects AO Auxiliary OFF temperature. FeaTimer On/OFF Heat To LRecord the number you select for future use Factory default is Loc On. You can make it Loc Off if youPress Menu after selecting the type of lockout Or buttonFan Operation Operating Your ThermostatCheck Thermostat Operation Heating SystemProgramming Worksheet for Re-Programming 5+1+1 and 7 Day Program Energy Saving Factory Pre-ProgramPlanning Your Program Important Enter the Heating Program Automatic Daylight Saving CalculationProgramming Tip Copy Program Enter the Cooling ProgramWeighing of Remote Reading Wired Remote Temperature SensingDual Fuel Temperature Setpoint Symptom Possible Cause Corrective Action TroubleshootingReset Operation Page Homeowner Help Line

1F95-0671 specifications

The White Rodgers 1F95-0671 is a versatile and advanced programmable thermostat designed primarily for residential heating and cooling systems. This innovative device provides homeowners with the ability to manage their indoor climate efficiently while maximizing energy savings.

One of the standout features of the 1F95-0671 is its user-friendly interface, which includes a large, easily readable touchscreen display. This modern touch interface simplifies temperature adjustments and programming, making it accessible for users of all ages. The display features bright, clear graphics that provide real-time temperature readings, system status, and schedule reminders.

The thermostat offers a 7-day programmable schedule, allowing users to set different temperature profiles for each day of the week. This flexibility ensures that you'll be comfortable when you're home while saving energy by reducing heating and cooling when the house is empty. The 1F95-0671 also includes a copy feature, enabling users to quickly replicate settings from one day to another, making programming even more convenient.

Equipped with advanced technology, the White Rodgers 1F95-0671 is compatible with multi-stage heating and cooling systems, including gas, oil, electric, and heat pump systems. Its adaptive recovery feature learns how long it takes to reach the desired temperature and adjusts the start time accordingly, increasing overall comfort without wasting energy.

Another key characteristic of this thermostat is its ability to monitor indoor humidity levels. This feature is especially beneficial in regions with extreme weather, providing an added layer of comfort while optimizing HVAC system performance. Users can set humidity levels independently of temperature, enhancing overall home comfort.

Energy efficiency is further promoted through the inclusion of Energy Star ratings, helping users track their energy consumption. The thermostat's smart alerts notify users of maintenance reminders, such as filter changes or system service needs, ensuring HVAC systems operate at their peak performance.

Wireless connectivity is another significant advantage of the 1F95-0671, allowing users to control their home environment remotely using compatible mobile devices. This feature offers a level of convenience and control that aligns with the modern digital lifestyle, providing peace of mind whether at home or away.

In summary, the White Rodgers 1F95-0671 thermostat combines user-friendly functionality, advanced heating and cooling technologies, and energy-efficient performance, making it an excellent choice for homeowners looking to optimize their indoor climate. Its robust features and smart connectivity set it apart as a leading option in the programmable thermostat market.