White Rodgers 1F95-1277 specifications Troubleshooting, Reset Operation

Page 11

TROUBLESHOOTING

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings, pressandand the SYSTEM button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or system.

Tighten connections.

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when a

 

 

may also be intermittent.

lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set SYSTEM Switch to HEAT and raise the

 

 

thermostat requires replacement.

setpoint above room temperature. Within a few seconds

 

 

 

the thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the

 

 

 

room temperature. There may be up to a five minute delay

 

 

 

before the thermostat clicks in Cooling.

 

 

 

 

Heat, Cool or Fan

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Runs Constantly

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3.

Possible short in heat/cool/fan system.

under terminal block. Try resetting the thermostat as

 

4.

FAN Switch set to Fan ON.

described above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration

Disagree

 

 

Menu section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle faster

Cycles Too Fast or Too Slow

 

the size of the Heating System may

than older mechanical models. The system turns on and

(narrow or wide

 

be influencing the cycle rate.

off more frequently but runs for a shorter time so there is

temperature swing)

 

 

no increase in energy use. If you would like an increased

 

 

 

cycle time, choose SL for slow cycle in the Configuration

 

 

 

menu, step 6 (heat) or 7 (cool). If an acceptable cycle rate

 

 

 

is not achieved, contact a local HVAC service person for

 

 

 

additional suggestions.

 

 

 

 

Forgot Keypad

 

 

Press the menu button (button will disappear) and hold in

Lockout Code

 

 

for 20 seconds. This unlocks the thermostat.

 

 

 

 

11

Image 11
Contents Save these instructions for future use SpecificationsApplications Battery Location InstallationWiring Connections Installing New ThermostatHome Screen Description Programming and Configuration ItemsThermostat Quick Reference Configuration Menu INSTALLER/CONFIGURATION MenuMode Fast rate INSTALLER/CONFIGURATION Menu Programming Operating Your ThermostatEntering Fan Program Enter the Heating ProgramEnter the Cooling Program Automatic ScheduleWorksheet for Re-Programming 5+1+1 and 7 Day Program Energy Saving Factory Pre-ProgramPlanning Your Program Important Dual Fuel Temperature Set Point Wired Remote Temperature SensingWeight of Remote Reading Reset Operation TroubleshootingSt. Louis, Missouri
Related manuals
Manual 1 pages 34.01 Kb

1F95-1277 specifications

The White Rodgers 1F95-1277 is a state-of-the-art digital thermostat designed for residential heating and cooling systems, providing homeowners with precision climate control while enhancing comfort and energy efficiency. One of the standout features of the 1F95-1277 is its user-friendly interface. The large, backlit display allows for easy reading under various lighting conditions, making it accessible for users of all ages. With simple touchscreen controls, navigating settings is intuitive, ensuring a seamless experience when adjusting temperature or accessing features.

A key technology integrated into the 1F95-1277 is its smart scheduling capability. This feature enables homeowners to set up customized heating and cooling schedules based on their daily or weekly routines. By programming the thermostat to adjust temperatures when occupants are away or sleeping, users can optimize energy use and reduce utility bills. Additionally, the thermostat is equipped with a 7-day programmable function, allowing for significant customization to fit individual schedules.

Another notable characteristic of the White Rodgers 1F95-1277 is its compatibility with a wide range of HVAC systems, including single-stage and multi-stage heating and cooling systems, as well as heat pumps. This versatility makes it an ideal choice for various home setups. Furthermore, the thermostat supports both conventional and heat pump systems, providing flexibility for homeowners with diverse heating sources.

The 1F95-1277 also incorporates advanced features such as energy-saving settings and alerts. Users can receive notifications when it’s time to change filters or if the temperature in the home reaches extreme levels, ensuring that they can address issues promptly. The device also has adaptive recovery functionality, which learns the home’s heating and cooling characteristics and adjusts accordingly to ensure the desired temperature is reached by the scheduled time.

Overall, the White Rodgers 1F95-1277 combines technological innovation with energy-efficient features, making it an excellent choice for homeowners looking to enhance their comfort and lower energy costs. Its ease of use and advanced functionalities position it as a reliable and effective solution for modern climate control needs.