White Rodgers 1F95-1277 specifications INSTALLER/CONFIGURATION Menu, Configuration Menu

Page 4

INSTALLER/CONFIGURATION MENU

To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays menu item #1 in the table below. Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item.

 

 

 

 

 

CONFIGURATION MENU

Menu

 

Non-

 

Displayed

Press

or

 

 

 

 

 

 

Reference

Program-

Program-

Press

(Factory

to select from

 

Number

mable

mable

Button

Default)

listed options

Comments

 

 

 

 

 

 

 

1

1

1

 

MS 2

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1

 

 

 

 

 

 

 

 

 

(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor

 

 

 

 

 

 

 

 

 

or 2 speed compressor), or Single Stage.

2

2

2

 

(ELE)

GAS

 

 

 

GAS setting: furnace controls blower.

 

 

 

 

 

 

 

 

 

ELE setting: thermostat controls blower.

3

3

3

 

Days, (7) P

5-1-1 or 0

Programs per week. (0 = non-programmable)

4

4

NA

 

PS (4)

2

 

 

 

Program periods per day.

 

 

 

 

 

 

 

 

 

4 = Morning, Day, Evening, Night

 

 

 

 

 

 

 

 

 

2 = Day, Night

5

5

4

 

Cool-Off-

Cool-Off-Heat,

System switch configuration in non heat pump mode.

 

 

 

 

Heat-Auto

Off-Heat, Cool-Off

 

 

 

 

 

Cool-Off-Heat-

Cool-Off-Heat-Emer,

System switch configuration, heat pump mode.

 

 

 

 

Emer-Auto

Off-Heat-Emer, Cool-Off

 

6

6

NA

 

E (On)

OFF

 

 

 

Selects Energy Management Recovery, E (with programming option on)

7

7

5

 

Cr, Heat (FA)

SL

 

 

 

Selects Adjustable Anticipation, cycle rate, Heat

8

8

6

 

Cr, Cool (FA)

SL

 

 

 

Selects Adjustable Anticipation, cycle rate, Cool

9

9

7

 

Cr/AU, Emer (FA)

SL

 

 

 

Selects Adjustable Anticipation, cycle rate auxiliary, (This item is

 

 

 

 

 

 

 

 

 

only to appear if HP 1 or HP 2 is selected above).

10

10

8

 

CL (OFF)

On

 

 

 

Selects Compressor Lockout.

11

11

9

 

dL (On)

OFF

 

 

 

Selects Continuous Display backlight & intensity.

12

12

10

 

dL (LO)

HI

 

 

 

Selects Backlight Intensity.

13

13

11

 

0

4, LO to 4, HI

Selects Adjustable Ambient Temperature Display [range -4 (LO) to

 

 

 

 

 

 

 

 

 

+4 (HI)].

14

14

12

 

°F

°C

 

 

 

Selects °F/°C Display (temperature units in Fahrenheit or Celsius).

15

15

13

 

b (On)

OFF

 

 

 

Selects audible Beeper On/Off.

16

16

14

 

dS (On)

OFF

 

 

 

Selects Daylight Saving Time calculation.

17

17

15

 

AS, Heat (On)

OFF

 

 

 

Selects Automatic Schedule for comfort temperature Programming,

 

 

 

 

 

 

 

 

 

heat mode.

18

18

16

 

AS, Cool (On)

OFF

 

 

 

Selects Automatic Schedule for comfort temperature Programming,

 

 

 

 

 

 

 

 

 

cool mode.

 

 

 

 

 

 

 

 

 

19

19

17

 

CS, (OFF)

1-2-3-4-5-6

 

 

Selects Cool Saving Feature & amount.

 

 

 

 

Cool Savings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

20

18

 

HL, Heat (99)

62-98

 

 

 

TEMPERATURE LIMIT, HEAT (max. heat set point).

21

21

19

 

LL, Cool (45)

46-82

 

 

 

TEMPERATURE LIMIT, COOL (min. cool set point).

22

22

20

 

OFF,

L (total), P (partial),

Selects Keypad Lockout.

 

 

 

 

Keypad Lockout

Temperature Limit

 

 

 

 

 

 

(limited temperature range)

 

 

 

 

 

000

001-999

 

 

Selects Keypad Lockout Combination (active only if keypad Lockout

 

 

 

 

 

 

 

 

 

is selected).

23

23

21

 

FS, Heat (On)

OFF

 

 

 

Fast second stage of heat (not available if SS1 is selected above).

24

24

22

 

FS, Cool (On)

OFF

 

 

 

Fast second stage of cool (not available if SS1 or HP1 is selected

 

 

 

 

 

 

 

 

 

above).

25

25

23

 

Remote (OFF)

On

 

 

 

Remote temperature sensor, enable/disable.

 

 

 

 

In, Remote

Outdoor Remote

Remote temperature sensor (Indoor/Outdoor).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LS (On)

OFF

 

 

 

Local temp. Sensor enable/disable (only when Indoor Remote is

 

 

 

 

 

 

 

 

 

selected On).

26

26

24

 

dF (5)

5-50

 

 

 

Selects Dual Fuel Feature & set point (in Fahrenheit) (applicable only

 

 

 

 

 

 

 

 

 

when HP1 or HP2 is selected).

 

 

 

 

Cd (60)

0-99

 

 

 

Selects Compressor delay in seconds (only when dF is selected >5).

27

27

25

 

Change Filter

On

 

 

 

Selects Change filter feature

 

 

 

 

(OFF)

 

 

 

 

 

 

 

 

 

200 Hours

25-1975 (in increments

Change filter, duration hours.

 

 

 

 

 

of 25 hours)

 

4

Image 4
Contents Applications SpecificationsSave these instructions for future use Installation Wiring ConnectionsInstalling New Thermostat Battery LocationThermostat Quick Reference Programming and Configuration ItemsHome Screen Description INSTALLER/CONFIGURATION Menu Configuration MenuMode Fast rate INSTALLER/CONFIGURATION Menu Operating Your Thermostat ProgrammingEnter the Heating Program Enter the Cooling ProgramAutomatic Schedule Entering Fan ProgramPlanning Your Program Important Energy Saving Factory Pre-ProgramWorksheet for Re-Programming 5+1+1 and 7 Day Program Weight of Remote Reading Wired Remote Temperature SensingDual Fuel Temperature Set Point Troubleshooting Reset OperationSt. Louis, Missouri
Related manuals
Manual 1 pages 34.01 Kb

1F95-1277 specifications

The White Rodgers 1F95-1277 is a state-of-the-art digital thermostat designed for residential heating and cooling systems, providing homeowners with precision climate control while enhancing comfort and energy efficiency. One of the standout features of the 1F95-1277 is its user-friendly interface. The large, backlit display allows for easy reading under various lighting conditions, making it accessible for users of all ages. With simple touchscreen controls, navigating settings is intuitive, ensuring a seamless experience when adjusting temperature or accessing features.

A key technology integrated into the 1F95-1277 is its smart scheduling capability. This feature enables homeowners to set up customized heating and cooling schedules based on their daily or weekly routines. By programming the thermostat to adjust temperatures when occupants are away or sleeping, users can optimize energy use and reduce utility bills. Additionally, the thermostat is equipped with a 7-day programmable function, allowing for significant customization to fit individual schedules.

Another notable characteristic of the White Rodgers 1F95-1277 is its compatibility with a wide range of HVAC systems, including single-stage and multi-stage heating and cooling systems, as well as heat pumps. This versatility makes it an ideal choice for various home setups. Furthermore, the thermostat supports both conventional and heat pump systems, providing flexibility for homeowners with diverse heating sources.

The 1F95-1277 also incorporates advanced features such as energy-saving settings and alerts. Users can receive notifications when it’s time to change filters or if the temperature in the home reaches extreme levels, ensuring that they can address issues promptly. The device also has adaptive recovery functionality, which learns the home’s heating and cooling characteristics and adjusts accordingly to ensure the desired temperature is reached by the scheduled time.

Overall, the White Rodgers 1F95-1277 combines technological innovation with energy-efficient features, making it an excellent choice for homeowners looking to enhance their comfort and lower energy costs. Its ease of use and advanced functionalities position it as a reliable and effective solution for modern climate control needs.