INSTALLER/CONFIGURATION MENU
Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press or to change a menu item options.
INSTALLER/CONFIGURATION MENU
MENU | HP | SS | PRESS | DISPLAYED | Press |
|
| or |
|
| to | COMMENTS |
|
|
|
| |||||||||
REF. |
|
| BUTTON | (FACTORY DE- |
|
|
|
|
| |||
|
| select from listed op- |
| |||||||||
|
|
|
| FAULT) |
|
| tions |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
1 | 1 | 1 | MENU | (MS 2) | HP 1, HP 2, SS 1 | Selects | ||||||
|
|
|
|
|
|
|
|
|
|
|
| Heat Pump 1 (HP 1, 1 compressor), |
|
|
|
|
|
|
|
|
|
|
|
| Heat Pump 2 (HP 2, 2 compressor or 2 |
|
|
|
|
|
|
|
|
|
|
|
| speed compressor), or Single Stage (SS 1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | 2 | 2 | MENU | (GAS) for SS or MS |
|
| ELE |
| GAS setting: furnace controls the blower | |||
|
|
|
|
|
|
|
|
|
|
|
| ELE setting: thermostat controls the blower |
|
|
|
|
|
|
|
|
|
|
|
|
|
3 | 3 | 3 | MENU | CS (3) | 0, 1, 2, 4, 5, 6 |
| Selects Cool Savings | |||||
|
|
|
|
|
|
|
|
|
|
|
| Value 1 (low) to 6 (high), |
|
|
|
|
|
|
|
|
|
|
|
| Value 0 disables feature |
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | 4 | 4 | MENU | E (On) |
|
| OFF |
| Selects Energy Management Recovery (EMR) | |||
|
|
|
|
|
|
|
|
|
|
|
| On or OFF. |
|
|
|
|
|
|
|
|
|
|
|
|
|
5 | – | 5 | MENU | CR Heat (ME) |
| SL, FA |
| Adjustable Anticipation: | ||||
|
|
|
|
|
|
|
|
|
|
|
| Selects heating cycle rate for MS or SS in #1 only |
|
|
|
|
|
|
|
|
|
|
|
|
|
6 | 5 | – | MENU | CR Heat Pump |
| SL, FA |
| Adjustable Compressor Anticipation | ||||
|
|
|
| (ME) |
|
|
|
|
|
|
| (Heat Pump) [only when heat pump (Heat/Cool) |
|
|
|
|
|
|
|
|
|
|
|
| selected in #1] |
|
|
|
|
|
|
|
|
|
|
|
|
|
7 | 6 | 6 | MENU | CR Cool (ME) |
| SL, FA |
| Adjustable Anticipation: | ||||
|
|
|
| or |
|
|
|
|
|
|
| Selects the cycle rate for cooling (only when |
|
|
|
| CR Au (FA) |
|
| SL |
| MS 2 or SS 1 is selected in item 1.) or | |||
|
|
|
|
|
|
|
|
|
|
|
| Selects the cycle rate for Emergency mode |
|
|
|
|
|
|
|
|
|
|
|
| and Auxiliary stage if Heat Pump is selected |
|
|
|
|
|
|
|
|
|
|
|
| in item 1. |
|
|
|
|
|
|
|
|
|
|
|
|
|
8 | 7 | 7 | MENU | CL (OFF) |
| CL On |
| Compressor Lockout Time | ||||
|
|
|
|
|
|
|
|
|
|
|
| |
9 | 8 | 8 | MENU | Cool Off, Em Heat | Heat Auto Cool Off, | System Mode Confi guration | ||||||
|
|
|
| Auto | Heat Off with Fan icon, | with Automatic Changeover capability | ||||||
|
|
|
|
| Heat Off without Fan icon |
| ||||||
|
|
|
|
| Cool Off, Auto Off |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
10 | 9 | 9 | MENU | dL (On) |
| dL OFF |
| Selects Display Light On or OFF | ||||
|
|
|
|
|
|
|
|
|
|
|
| |
11 | 10 | 10 | MENU | 0 | 1 HI, 2 HI, 3HI, 4 HI, | Adjustable Ambient Temperature Display | ||||||
|
|
|
| (current temperature) | 1 LO, 2 LO, 3 LO, 4 LO |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
12 | 11 | 11 | MENU | °F |
|
| °C |
| Selects Fahrenheit/Celsius Temperature Display | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
13 | 12 | 12 | MENU | (On) b |
|
| OFF |
| May select Beeper OFF to stop audible | |||
|
|
|
|
|
|
|
|
|
|
|
| key feedback |
|
|
|
|
|
|
|
|
|
|
|
|
|
14 | 13 | 13 | MENU | P (7) |
| 3, 0 |
|
|
| Defaults | ||
|
|
|
|
|
|
|
|
|
|
|
| programmable (0) or 5/1/1 programming (P3) |
|
|
|
|
|
|
|
|
|
|
|
| is available on most models. |
|
|
|
|
|
|
|
|
|
|
|
|
|
15 | 14 | 14 | MENU | PS (2) |
| 4 |
|
|
| Selects Program periods per day: | ||
|
|
|
|
|
|
|
|
|
|
|
| 4 = Morn, Day, Eve, Night |
|
|
|
|
|
|
|
|
|
|
|
| 2 = Day, Night |
|
|
|
|
|
|
|
|
|
|
|
|
|
16 | 15 | 15 | MENU | Heat AS (On) |
|
| OFF |
| Automatic Schedule for heat mode | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
17 | 16 | 16 | MENU | Cool AS (On) |
|
| OFF |
| Automatic Schedule for cool mode | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
18 | 17 | – | MENU | Heat FA (On) |
|
| OFF |
| Fast Heat option may be disabled by | |||
|
|
|
|
|
|
|
|
|
|
|
| selecting OFF. NA to SS or HP1 confi g. |
|
|
|
|
|
|
|
|
|
|
|
|
|
19 | 18 | – | MENU | Cool FA (On) |
|
| OFF |
| Fast Cool option may be disabled by | |||
|
|
|
|
|
|
|
|
|
|
|
| selecting OFF. NA to SS or HP1 confi g. |
|
|
|
|
|
|
|
|
|
|
|
|
|
20 | 19 | 17 | MENU | Remote (OFF) |
|
| On |
| Selects Remote Sensor On/OFF | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MENU | Remote |
| Outdoor |
| Selects Remote Sensor to outdoor | ||||
|
|
|
| (In) |
|
|
|
|
|
|
| NA is Remote Sensor OFF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MENU | Indoor Loc |
|
| OFF |
| Selects Local Sensor (in thermostat) to OFF. | |||
|
|
|
| (On) |
|
|
|
|
|
|
| N/A if Remote is selected to Outdoor |
|
|
|
|
|
|
|
|
|
|
|
|
|
5