White Rodgers 37-5086B, 37-5086A installation instructions Thermostat

Page 4

NOTE

All wiring diagrams are for typical systems only. Refer to equipment manufacturers’ instructions for specific sys- tem wiring information.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse box or circuit breaker until installation is complete.

THERMOSTAT

6

MV

Y

G

W

RC

RH

SYSTEM

Heating

System

Hot

 

 

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

Neutral

TRANSFORMER

From heating system

From 24 VAC transformer

6W

MV

W

RC

 

G

RH

Y

RH

 

Thermostat Terminal Connections

Figure 4. Typical wiring diagram for heat only, 2-wire, single transformer systems

6

MV

Y

NOTE

RED jumper wire (pro- vided with thermostat) must be connected be- tween thermostat's RH and RC terminals for pro- per thermostat operation with this system.

G

Fan

Relay

JUMPER

WIRE

THERMOSTAT

WRCRH

SYSTEM

Heating

System

 

 

 

 

 

 

 

 

Hot

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

TRANSFORMER

From 24 VAC

transformer

From heating system

6

W

W

RC

MV

G

G

RH

Y

RH

From fan relay

CONNECT red jumper

wire (provided)

Thermostat Terminal Connections

Figure 5. Typical wiring diagram for heat only, 3-wire, single transformer systems

 

 

 

 

 

 

 

 

 

From 24 VAC

 

 

 

 

 

 

 

 

 

 

transformer

 

 

6

MV

Y

G

W

RC

RH

THERMOSTAT

6

 

 

W

SYSTEM

 

 

 

 

 

 

 

 

 

MV

 

 

RC

 

 

Cooling

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

System

Relay

 

 

 

 

 

RC

G

 

 

 

 

 

 

 

Hot

 

 

Y

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC

120 VAC

RH

 

 

From fan relay

 

 

 

 

 

 

 

Neutral

 

 

From cooling system

 

 

 

 

 

 

TRANSFORMER

 

Thermostat Terminal Connections

 

 

 

 

 

 

 

 

 

Figure 6. Typical wiring diagram for cool only, 3-wire, single transformer systems

6MV

NOTE

RED jumper wire (pro- vided with thermostat) must be connected be- tween thermostat's RH and RC terminals for pro- per thermostat operation with this system.

JUMPER

WIRE

THERMOSTAT

Y

G

W RC

RH

Cooling

System

Fan

Relay

Heating

System

SYSTEM

Hot

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

Neutral

TRANSFORMER

From heating system

CONNECT red jumper

wire (provided)

6

 

W

W

MV

 

 

RC

 

 

G

G

 

RH

Y

Y

RH

 

 

From fan relay

From 24 VAC

 

From cooling system

 

 

 

transformer

 

 

 

Thermostat Terminal Connections

Figure 7. Typical wiring diagram for heat/cool, 4-wire, single transformer systems

4

Image 4
Contents Contents PrecautionsDescription Specifications Installation NEW InstallationRoute Wires to Location Select Thermostat LocationRemove OLD Thermostat Replacement InstallationAttach Subbase to Wall Thermostat Typical wiring diagram for millivolt systems Operation System Configuration SET Group a Option SwitchesSET Group B Option Switches Attach Thermostat to SubbaseCheck Thermostat Operation Heating SystemElectric Heat Systems FAN OperationSystem Configuration TroubleshootingCooling System