GAS CONNECTION INSTALLATION INSTRUCTIONS
GAS CONNECTION (Line Supply)
A 3/8” Flair gas line connection is supplied in the heater
GAS SUPPLY LINE TO HEATER
a.Remove top panel from heater by lifting top panel.
b.Remove front and rear panel.
c.Remove rubber grommet from back panel of heater and insert gas supply line through back panel of heater.
d.Connect gas supply line to flexible gas hose. Ensure that flexible gas hose is not kinked after fitting gas supply line.
e.After gas supply line has been brought through from rear of heater, place rubber grommet supplied over gas line and install panels.
FLEXIBLE GAS
LINE
Figure 39
Note: The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its location for servicing of the heater. For fireplace insert installations, incorporate either a copper loop into the supply line or flexible hose being used for the gas supply to the heater to allow for easy removal of the appliance.
Note: Under no circumstances should the gas supply line to the appliance be installed under conditions, which would not allow for easy removal of the appliance to carry out routine inspection and service to the appliance.
Page 34 |