Desa (V)T32P SERIES, (V)T32N SERIES Operating Fireplace, For your safety Read before lighting

Page 27

Operating Fireplace

for your safety

read before lighting

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE:Duringinitialoperationof new heater, burning logs will give offapaper-burningsmell.Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, above.

2.Open lower louver panel.

3.Turn off all electric power to the fireplace.

4.Push in gas control knob slightly and turn

clockwise to OFF.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you don’t smell gas, go to the next step.

6.The pilot is located by the main burner and should not require accessing for lighting.

7.Turn gas control knob counterclockwise to PILOT.

8.Push in gas control knob all the way and hold. Immediately light pilot by repeatedly depressing piezo spark ignitor until a flame appears. Continue to hold for about 1 min- ute after pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 4 through 7.

If gas control knob does not pop up when released, stop and immediately call our service technician or gas supplier.

If pilot will not stay lit after several tries, turn gas control knb to OFF and call your service technician or gas supplier.

9.Turn on all electric power to the fireplace.

10.Turn gas control knob counterclockwise to ON.

11.This valve is equipped with a HI/LO fea- ture. Set fireplace input as desired.

12.Close lower louver panel.

Gas Control

 

 

 

Variable Control Knob

Knob

 

 

 

 

Piezo

 

 

 

 

Ignitor

 

F

T

IH

 

 

 

PILO

 

F

 

 

O

 

O

 

 

 

 

 

 

N

 

 

 

 

LO

Figure 50 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn

clockwise to OFF.

5. Close lower louver panel.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

111986-01D

www.desatech.com

27

Image 27
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information High traffic areas Product FeaturesLocal Codes Product IdentificationProper clearances must be maintained Pre-Installation PreparationLocation and space requirements This fireplace does not require electricity to operateVenting clearances ClearancesFraming and finishing Front Top of Standoffs Vent See ventingBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Recommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationNumber Description Desa Venting AccessoriesDesa Elbows Desa TerminationsCheck GAS Type Fireplace InstallationInstalling optional blower accessories Model BK InstallationPlug in blower power cord to duplex outlet Model BKT InstallationInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsInstalling optional wall mount switch GWMS2 Installing Remote ReceiverOpen bottom louver and locate the switch Removing Glass Door Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsInstalling Optional Brick liner Model BL32D Installing logs, lava rock and glowing embersClose top and bottom louvers Installing Log No To Turn OFF GAS To Appliance For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureOptional Hand-Held On/Off Series Models HRC100 and HRC101Key Pad Lock Feature Operating optional blower accessorySafety Features Auto Shutoff FeatureBurner Flame Pattern Cleaning MaintenancePilot Assembly Inspecting BurnersPilot and burners LogsVenting system Observed Problem Possible Cause Remedy TroubleshootingAfter pilot lights, keep gas Mocouple to cool, causingProblem could be caused by Replace pilot assembly Burner orifice clogged Clean burner see Cleaning Is litTery power is low When burner is litDirty or partially clogged 3. Clean burner see Cleaning Or shut off Service person Remote does not functionStatement above Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceDeflection hood Wall mounted on/off switch gwms2 Not ShownFace/Louver Panel kit Rolled Louver Trim kitIllustrated Parts Breakdown Parts List Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

(V)T32N SERIES, (V)T32P SERIES specifications

Desa (V)T32P and (V)T32N Series are cutting-edge technological offerings from Desa, known for their precision and reliability in high-performance applications. These series are designed to meet the evolving needs of engineers and manufacturers in various sectors, including automotive, aerospace, and industrial automation. Both series boast an impressive array of features that enhance functionality, efficiency, and safety.

One of the main features of the (V)T32P Series is its advanced processing capabilities. These models come equipped with powerful processors that enable rapid data handling and processing. This makes them ideal for applications that require real-time monitoring and control. Additionally, the series supports a wide range of input and output options, allowing seamless integration into diverse systems.

The (V)T32N Series, on the other hand, focuses on connectivity and data communication. These models incorporate state-of-the-art networking technologies, including Ethernet, Wi-Fi, and various industrial communication protocols. This enables easy integration into existing networks, promoting collaborative environments where information can be shared quickly and securely. The series also features enhanced security protocols to safeguard sensitive data against cyber threats.

Both series are built with durability in mind. They utilize robust materials and advanced manufacturing techniques to withstand harsh operating conditions, reducing downtime and maintenance costs. Additionally, the devices in these series have been designed to be energy-efficient, adhering to industry standards and providing cost savings over time.

Another significant characteristic of both the (V)T32P and (V)T32N Series is their user-friendly interfaces. With intuitive controls and clear display options, users can easily navigate through settings and configurations, ensuring quick adaptation and efficient operation. This ease of use is further complemented by comprehensive documentation and support resources provided by Desa, ensuring that users can maximize the capabilities of their systems.

In summary, the Desa (V)T32P and (V)T32N Series represent a leap forward in technology for professionals seeking reliable, efficient, and user-friendly solutions. Their powerful processing capabilities, advanced connectivity options, durability, and ease of use make them ideal choices for a variety of applications, ensuring that users are well-equipped to tackle the challenges of modern engineering and manufacturing.