Desa (V)T32N SERIES, (V)T32P SERIES installation manual Warranty Information, Keep this Warranty

Page 40

Warranty Information

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

DIRECT-VENT FIREPLACE

DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized retailers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUEN- TIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights and you may also have other rights that vary from state to state. For information about this warranty write:

2701 Industrial Drive P.O. Box 90004

Bowling Green, KY 42102-9004 www.desatech.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

111986-01

 

111986 01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev. D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOT A UPC

03/06

Image 40
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Features Local CodesProduct Identification High traffic areasPre-Installation Preparation Location and space requirementsThis fireplace does not require electricity to operate Proper clearances must be maintainedClearances Framing and finishingFront Top of Standoffs Vent See venting Venting clearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Snorkel Termination Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingDesa Venting Accessories Desa ElbowsDesa Terminations Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Check GAS TypeModel BKT Installation Plug in blower power cord to duplex outletBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Remote Receiver Installing optional wall mount switch GWMS2Open bottom louver and locate the switch Cleaning Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass DoorInstalling logs, lava rock and glowing embers Installing Optional Brick liner Model BL32DClose top and bottom louvers Installing Log No For your safety Read before lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Optional Hand-HeldOn/Off Series Models HRC100 and HRC101 Remote OperationOperating optional blower accessory Safety FeaturesAuto Shutoff Feature Key Pad Lock FeatureCleaning Maintenance Pilot AssemblyInspecting Burners Burner Flame PatternLogs Pilot and burnersVenting system Troubleshooting Observed Problem Possible Cause RemedyMocouple to cool, causing Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasWhen burner is lit Dirty or partially clogged 3. Clean burner see CleaningOr shut off Service person Remote does not function Tery power is lowGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service SpecificationsWall mounted on/off switch gwms2 Not Shown Face/Louver Panel kitRolled Louver Trim kit Deflection hoodIllustrated Parts Breakdown Parts List Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

(V)T32N SERIES, (V)T32P SERIES specifications

Desa (V)T32P and (V)T32N Series are cutting-edge technological offerings from Desa, known for their precision and reliability in high-performance applications. These series are designed to meet the evolving needs of engineers and manufacturers in various sectors, including automotive, aerospace, and industrial automation. Both series boast an impressive array of features that enhance functionality, efficiency, and safety.

One of the main features of the (V)T32P Series is its advanced processing capabilities. These models come equipped with powerful processors that enable rapid data handling and processing. This makes them ideal for applications that require real-time monitoring and control. Additionally, the series supports a wide range of input and output options, allowing seamless integration into diverse systems.

The (V)T32N Series, on the other hand, focuses on connectivity and data communication. These models incorporate state-of-the-art networking technologies, including Ethernet, Wi-Fi, and various industrial communication protocols. This enables easy integration into existing networks, promoting collaborative environments where information can be shared quickly and securely. The series also features enhanced security protocols to safeguard sensitive data against cyber threats.

Both series are built with durability in mind. They utilize robust materials and advanced manufacturing techniques to withstand harsh operating conditions, reducing downtime and maintenance costs. Additionally, the devices in these series have been designed to be energy-efficient, adhering to industry standards and providing cost savings over time.

Another significant characteristic of both the (V)T32P and (V)T32N Series is their user-friendly interfaces. With intuitive controls and clear display options, users can easily navigate through settings and configurations, ensuring quick adaptation and efficient operation. This ease of use is further complemented by comprehensive documentation and support resources provided by Desa, ensuring that users can maximize the capabilities of their systems.

In summary, the Desa (V)T32P and (V)T32N Series represent a leap forward in technology for professionals seeking reliable, efficient, and user-friendly solutions. Their powerful processing capabilities, advanced connectivity options, durability, and ease of use make them ideal choices for a variety of applications, ensuring that users are well-equipped to tackle the challenges of modern engineering and manufacturing.