Desa (V)gM36h Flashing installation v6f-10dm or v12f-10dm, Storm Collar Installation SC2-1

Page 11

Venting Installation

Continued

4.Remove the shingles around the opening measured. Cut out this section.

5.Add the next sections of the pipe until the end penetrates the roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof.

Storm Collar Installation (SC2-1)

Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 14). Apply waterproof caulk around the perimeter of the collar to provide a proper seal.

Chimney

Waterproof

Pipe

Caulk

Storm

Flashing

Collar

Flashing installation (v6f-10dm or v12f-10dm)

Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 13). DO NOT NAIL THROUGH FLASHING CONE.

Installing Flashing on a Metal Roof

When installing the flashing on a metal roof, it is required that putty tape be used between the flash- ing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal.

Storm

Overlap

Collar

Shingles Top

Flashing

and Sides Only

Cone

 

Nail Only

Outer

Perimeter

of Flashing

Underlap

Shingles

at Bottom

Figure 13 - Flashing Installation

Figure 14 - Storm Collar

Terminations/Spark Arrestor

The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination.

CAUTION: Do not seal open- ings on the rooftop flashing. Fol- low the installation instructions provided with the termination being used.

 

RTL-10D

Stainless

Level of

Inner Flue

Pipe

Flue Gas

 

Outlet

Secure

 

Termination

 

to Outer

Waterproof

Pipe with 3

Caulking

Screws

Storm

 

 

Collar

 

Flashing

Overlap

 

Shingles (Top

Underlap

and Sides of

Shingles

Flashing Base)

 

Figure 15 - Termination

112435-01M

www.desatech.com

11

Image 11
Contents Save this Book Safety Information Table of ContentsModels VGM36H and GM36H SpecificationsModels VGM42H and GM42H Models VGM50H and GM50H Framing Fireplace InstallationSelecting location Minimum clearance to combustiblesMantels Hearth ExtensionChimney Pipe Venting InstallationAssembly and installation of double wall chimney system Optional Outside air Kit Model ak4/ak4fElbow SET only Using Elbow offsets 30E-12DMRoof Opening GM42/50 Firestop Spacers FS-10, 1100EFS-10DM for GM36Penetrating the roof Roof Opening GM36Terminations/Spark Arrestor Flashing installation v6f-10dm or v12f-10dmStorm Collar Installation SC2-1 Installing Flashing on a Metal RoofFinishing the fireplace Optional Gas Line InstallationChase installations Foot ruleGas Line Knockout Installing Brick S Brick InstallationHerringbone Brick Installation for Model VGM36H Standard Brick Installation for Model VGM36Herringbone Brick Installation for Model VGM42H Standard Brick Installation for Model VGM42Herringbone Brick Installation for Model VGM50H Standard Brick Installation for Model VGM50Herringbone Brick Matrix VGM36H Standard Brick Matrix VGM36Herringbone Brick Matrix VGM42H Standard Brick Matrix VGM42Herringbone Brick Matrix VGM50H Standard Brick Matrix VGM50Model Distance Apart Installing Z-shaped Grate Retainer BracketGrouting instructions Door frame Models BDMO36E/G/C, BDMO42E/G/C and BDMO50E/G/C Glass Door InstallationAssembly InstallationGlass Doors Operation Maintenance GuidelinesInstalling glass doors Door AdjustmentOutside air and damper handle operation Technical ServiceCleaning Glass Offset and Return Replacement and Accessory PartsBi-Fold Glass Masonry Door GrateV6F-10DM 0 to 6/12 Pitch V12F-10DM 6/12 to 12/12 Pitch Roof FlashingRound ToP TErminations RLT-12D and RLT-12HT 112435-01M Not a UPC

(V)gM36, (V)gM36h, (V)gM42h, (V)gM42, (V)gM50h specifications

Desa (V)gM36h, (V)gM42h, (V)gM42, (V)gM50h, and (V)gM50 are advanced models of the Desa family, showcasing a blend of innovative technologies and robust characteristics designed for versatile functionality in various environments. These models gain recognition for their performance in both residential and commercial applications, each tailored to meet specific user needs.

The (V)gM36h model stands out with its compact design yet powerful capability. It features high energy efficiency, which contributes to lower operational costs while maintaining exceptional performance. The model operates with an advanced control system allowing precise temperature adjustment, ensuring user comfort and energy optimization.

Meanwhile, the (V)gM42h enhances the features of the 36h model with added functionality. Its integration of smart technology allows remote management through mobile applications, facilitating ease of use. The (V)gM42h comes equipped with a self-diagnosis feature that monitors system performance in real-time, alerting the user to potential issues before they become significant problems.

The (V)gM42 is designed with sustainability in mind. It utilizes eco-friendly refrigerants that comply with environmental regulations while delivering optimal cooling and heating performance. This model is also noted for its noise reduction technology, making it an ideal choice for residential spaces where tranquility is paramount.

On the higher end, the (V)gM50h model combines enhanced capacity with advanced features that cater to larger spaces. It integrates variable-speed technology, allowing the system to adjust its output dynamically, which enhances energy efficiency and comfort. The (V)gM50h also includes a robust filtration system that improves indoor air quality by minimizing pollutants.

Finally, the (V)gM50 serves as a flagship offering, combining all the notable advantages of its predecessors with even greater performance efficiency and user-friendly features. It is engineered for heavy-duty performance, making it suitable for demanding commercial applications while still maintaining a user-centric approach for ease of operation.

Collectively, the Desa models represent a significant advancement in temperature control technology, combining energy efficiency, user-friendly features, and environmental considerations to meet the modern demands of users across various sectors.