Desa (V)gM36, (V)gM42, (V)gM50 Firestop Spacers FS-10, 1100EFS-10DM for GM36, Penetrating the roof

Page 10

Venting Installation

Continued

Screws

B

A

Figure 9 - Elbow Offset

Firestop Spacers (FS-10, 1100EFS-10DM for GM36)

Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 10.

They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 11.

Existing

Ceiling

Frame

Penetrating the roof

To maintain a 1" (GM36) or 2" (GM42/GM50) clearance to the pipe on a roof with a pitch, a rectangular opening must be cut.

1.Determine the center point through which the pipe will penetrate the roof.

2.Determine the center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters.

3.Use the roof opening chart (Figure 12) to determine the correct opening length and flashing required.

17" Min.

30" Min.

 

 

1" Min.

 

1" Min.

 

1" Min.

 

Opening "A"

Pitch

Slope

Opening

Used Flashing

 

 

"A" Max.

Model No.

Flat

17"

V6F-10DM

0-6/12

26.6°

19"

V6F-10DM

6/12-

45.0°

24"

V12F-10DM

12/12

 

 

 

Roof Opening GM36

Firestop Spacer

Screws or Staples (Min. of 8)

Figure 10 - Firestop Spacer with Living

Space Above Ceiling

Screws or Staples

Firestop(Min. of 8) Spacer

19.5" Min.

2" Min.

2" Min.

30" Min.

2" Min.

Opening "A"

Existing

Ceiling

Frame

Figure 11 - Firestop Spacer with Attic

Space Above Ceiling

Pitch

Slope

Opening

Used Flashing

 

 

"A" Max.

Model No.

Flat

19.5"

V6F-10DM

0-6/12

26.6°

22'

V6F-10DM

6/12-

45.0°

27"

V12F-10DM

12/12

 

 

 

Roof Opening GM42/50

Figure 12 - Roof Opening Measurements

10

www.desatech.com

112435-01M

Image 10
Contents Save this Book Table of Contents Safety InformationSpecifications Models VGM36H and GM36HModels VGM42H and GM42H Models VGM50H and GM50H Minimum clearance to combustibles Fireplace InstallationSelecting location FramingHearth Extension MantelsOptional Outside air Kit Model ak4/ak4f Venting InstallationAssembly and installation of double wall chimney system Chimney PipeUsing Elbow offsets 30E-12DM Elbow SET onlyRoof Opening GM36 Firestop Spacers FS-10, 1100EFS-10DM for GM36Penetrating the roof Roof Opening GM42/50Installing Flashing on a Metal Roof Flashing installation v6f-10dm or v12f-10dmStorm Collar Installation SC2-1 Terminations/Spark ArrestorFoot rule Optional Gas Line InstallationChase installations Finishing the fireplaceGas Line Knockout Brick Installation Installing Brick SStandard Brick Installation for Model VGM36 Herringbone Brick Installation for Model VGM36HStandard Brick Installation for Model VGM42 Herringbone Brick Installation for Model VGM42HStandard Brick Installation for Model VGM50 Herringbone Brick Installation for Model VGM50HStandard Brick Matrix VGM36 Herringbone Brick Matrix VGM36HStandard Brick Matrix VGM42 Herringbone Brick Matrix VGM42HStandard Brick Matrix VGM50 Herringbone Brick Matrix VGM50HGrouting instructions Installing Z-shaped Grate Retainer BracketModel Distance Apart Installation Glass Door InstallationAssembly Door frame Models BDMO36E/G/C, BDMO42E/G/C and BDMO50E/G/CDoor Adjustment Operation Maintenance GuidelinesInstalling glass doors Glass DoorsCleaning Glass Technical ServiceOutside air and damper handle operation Grate Replacement and Accessory PartsBi-Fold Glass Masonry Door Offset and ReturnRound ToP TErminations RLT-12D and RLT-12HT Roof FlashingV6F-10DM 0 to 6/12 Pitch V12F-10DM 6/12 to 12/12 Pitch 112435-01M Not a UPC

(V)gM36, (V)gM36h, (V)gM42h, (V)gM42, (V)gM50h specifications

Desa (V)gM36h, (V)gM42h, (V)gM42, (V)gM50h, and (V)gM50 are advanced models of the Desa family, showcasing a blend of innovative technologies and robust characteristics designed for versatile functionality in various environments. These models gain recognition for their performance in both residential and commercial applications, each tailored to meet specific user needs.

The (V)gM36h model stands out with its compact design yet powerful capability. It features high energy efficiency, which contributes to lower operational costs while maintaining exceptional performance. The model operates with an advanced control system allowing precise temperature adjustment, ensuring user comfort and energy optimization.

Meanwhile, the (V)gM42h enhances the features of the 36h model with added functionality. Its integration of smart technology allows remote management through mobile applications, facilitating ease of use. The (V)gM42h comes equipped with a self-diagnosis feature that monitors system performance in real-time, alerting the user to potential issues before they become significant problems.

The (V)gM42 is designed with sustainability in mind. It utilizes eco-friendly refrigerants that comply with environmental regulations while delivering optimal cooling and heating performance. This model is also noted for its noise reduction technology, making it an ideal choice for residential spaces where tranquility is paramount.

On the higher end, the (V)gM50h model combines enhanced capacity with advanced features that cater to larger spaces. It integrates variable-speed technology, allowing the system to adjust its output dynamically, which enhances energy efficiency and comfort. The (V)gM50h also includes a robust filtration system that improves indoor air quality by minimizing pollutants.

Finally, the (V)gM50 serves as a flagship offering, combining all the notable advantages of its predecessors with even greater performance efficiency and user-friendly features. It is engineered for heavy-duty performance, making it suitable for demanding commercial applications while still maintaining a user-centric approach for ease of operation.

Collectively, the Desa models represent a significant advancement in temperature control technology, combining energy efficiency, user-friendly features, and environmental considerations to meet the modern demands of users across various sectors.