WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

DIRECT-VENT FIREPLACE

DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized retailers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESAʼS LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive P.O. Box 90004

Bowling Green, KY 42102-9004 www.desatech.com

116236 01

NOT A UPC

116236-01

 

Rev. B

 

02/05

Image 40
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySave this manual for future reference Table of Contents Safety InformationProduct Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Combustible Horizontal Termination Configurations Vertical Horizontal HCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingVenting Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Blower see FigureBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyOr servicing. Correct all leaks at once Installing Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Doors Installing Brick Liner Models BL42DASA and BL42 Dhasa For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsManual Lighting Procedure To Turn OFF GASTo Appliance Optional HAND-HELD Remote OperationSafety Features Manual ModeAuto Thermostatic Mode ON/OFF Series Model GhrcbOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible Cause RemedyBrick Liner Models BL42DASA Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Models VC42N, VC42P, VVC42N and VVC42P SeriesParts List KEY Part Number Description QTY19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01B Warranty Information

(V)VC42P SERIES, (V)VC42N SERIES specifications

The Desa (V)VC42P and (V)VC42N Series are advanced solutions in the HVAC and thermal control industry, designed to provide efficient climate management for various applications. These series are noted for their commitment to performance, reliability, and energy efficiency, making them popular choices among users looking for modern heating and ventilation systems.

One of the main features of the (V)VC42P and (V)VC42N Series is their state-of-the-art variable speed technology. This technology allows the units to adjust their output based on the specific heating or cooling needs of a space. By operating at different speeds, the systems can maintain a more consistent temperature while using less energy compared to traditional fixed-speed systems. This leads to significant cost savings and enhanced comfort for occupants.

Additionally, both series incorporate advanced control systems that can be easily integrated with smart home technologies. Users can remotely monitor and adjust their HVAC systems via mobile applications or voice-activated devices, facilitating greater control over their indoor climate. This compatibility with smart technologies not only enhances user experience but also contributes to energy conservation efforts by allowing for better management of usage patterns.

Another characteristic of the Desa (V)VC42P and (V)VC42N Series is their robust construction and design. Built with high-quality materials, these units demonstrate durability and reliability over time. The compact design of these systems allows for flexible installation options, making them suitable for various residential and commercial environments.

Moreover, the series prioritizes low noise operation, ensuring that the units run quietly without disturbing the peace in homes or workplaces. This feature is particularly essential in settings where noise control is critical, such as in offices, schools, or healthcare facilities.

In summary, the Desa (V)VC42P and (V)VC42N Series stand out in the HVAC market due to their variable speed technology, smart home compatibility, durable construction, and low noise operation. With their innovative features and characteristics, these systems are well-equipped to provide effective and efficient climate control solutions tailored to modern living and working environments.