Desa (V)VC42N SERIES, (V)VC42P SERIES installation manual Parts List

Page 35

PARTS LIST

Models VC42N, VC42P, VVC42N and VVC42P Series

35

PARTS LIST

BURNER ASSEMBLY FOR MODELS

VC42N, VC42P, VVC42N AND VVC42P SERIES

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

**

Burner Pan Assembly

1

2

**

Base Grate

1

3

**

Firebox Base Bottom

1

4

**

Valve Bracket

1

5

11107

Screw, #10-32 x 1/4 Zinc

4

6

**

Firebox Bottom

1

7

11102

Screw, #8-32 x 3/8 Zinc

2

8

116344-01

Tubing Assembly

1

9

111288-02

Flex Gas Line

1

10

108084-02

Pilot Assembly (Natural Gas)

1

 

108084-03

Pilot Assembly (Propane/LP Gas)

1

11

14389

Natural Gas Valve

1

 

14390

Propane/LP Gas Valve

1

12

11165

Screw, #10 x 5/8 Zinc

23

13

111913-02

Burner Base Gasket

1

14

14396

Brass Fitting

2

15

116345-01

Pilot Bracket

1

16

26827

Switch Bracket

1

17

11226

Flat Washer 7/8" ID x 2" OD

2

18

11214

Bulkhead Fitting with Washer

2

19

14296

Elbow 3/8"

1

20

24874

Burner Orifice #32 (Natural Gas)

1

 

23098

Burner Orifice #50 (Propane/LP Gas)

1

21

11492

Piezo

1

22

14511

Piezo Bracket

1

 

 

 

 

** Not a field replaceable part.

116236-01B

www.desatech.com

Image 35
Contents Save this manual for future reference For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Vertical Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Venting InstallationFireplace Installation Installing Optional Blower AccessoriesBlower see Figure Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Or servicing. Correct all leaks at once Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Removing Louver Panels Installing Remote ReceiverREMOVING/REPLACING Glass Door Removing Glass Doors Installing Lava Rock and Glowing EmbersCleaning Glass Door Lighting Instructions Installing Brick Liner Models BL42DASA and BL42 DhasaFor Your Safety Read Before Lighting Operating FireplaceOptional HAND-HELD Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To ApplianceON/OFF Series Model Ghrcb Safety FeaturesManual Mode Auto Thermostatic ModeOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingBrick Liner Models BL42DASA Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceModels VC42N, VC42P, VVC42N and VVC42P Series Illustrated Parts BreakdownKEY Part Number Description QTY Parts List19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01B Warranty Information

(V)VC42P SERIES, (V)VC42N SERIES specifications

The Desa (V)VC42P and (V)VC42N Series are advanced solutions in the HVAC and thermal control industry, designed to provide efficient climate management for various applications. These series are noted for their commitment to performance, reliability, and energy efficiency, making them popular choices among users looking for modern heating and ventilation systems.

One of the main features of the (V)VC42P and (V)VC42N Series is their state-of-the-art variable speed technology. This technology allows the units to adjust their output based on the specific heating or cooling needs of a space. By operating at different speeds, the systems can maintain a more consistent temperature while using less energy compared to traditional fixed-speed systems. This leads to significant cost savings and enhanced comfort for occupants.

Additionally, both series incorporate advanced control systems that can be easily integrated with smart home technologies. Users can remotely monitor and adjust their HVAC systems via mobile applications or voice-activated devices, facilitating greater control over their indoor climate. This compatibility with smart technologies not only enhances user experience but also contributes to energy conservation efforts by allowing for better management of usage patterns.

Another characteristic of the Desa (V)VC42P and (V)VC42N Series is their robust construction and design. Built with high-quality materials, these units demonstrate durability and reliability over time. The compact design of these systems allows for flexible installation options, making them suitable for various residential and commercial environments.

Moreover, the series prioritizes low noise operation, ensuring that the units run quietly without disturbing the peace in homes or workplaces. This feature is particularly essential in settings where noise control is critical, such as in offices, schools, or healthcare facilities.

In summary, the Desa (V)VC42P and (V)VC42N Series stand out in the HVAC market due to their variable speed technology, smart home compatibility, durable construction, and low noise operation. With their innovative features and characteristics, these systems are well-equipped to provide effective and efficient climate control solutions tailored to modern living and working environments.