Desa (V)VC42N SERIES, (V)VC42P SERIES Parts List, KEY Part Number Description QTY

Page 33

PARTS LIST

Models VC42N, VC42P, VVC42N and VVC42P Series

33

PARTS LIST

MODELS

VC42N, VC42P, VVC42N AND VVC42P SERIES

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

1

**

Firebox Assembly

1

2

**

Face Weldment

1

3

108328-01

Door Assembly

1

 

108328-02

Door Assembly (V Models Only)

1

4

108331-01

Top Louver Assembly

1

5

108331-02

Bottom Louver Assembly

1

6

**

Fireplace Top

1

7

**

Fireplace Top Insulation

1

8

**

Fireplace Surround

1

9

109082-01

Heat Shield

1

10

116216-01

Grate/Log Set Assembly

1

11

116338-01

Right Burner Log

1

12

116339-01

Left Burner Log

1

13

See Below

Left Refractory Brick Panel

1

14

See Below

Rear Refractory Brick Panel

1

15

See Below

Right Refractory Brick Panel

1

16

108455-01

Screen Rod

1

17

107840-01

Screen

2

18

11418

Push-On Nut

2

19

14123

Strain Relief

1

20

21171

Gas Knock-Out Cover

2

21

24353

Handy Box Assembly

1

22

24460

Gas Conduit Assembly

1

23

116211-01

Burner Assembly (Natural Gas)(See page 34)

1

 

116211-02

Burner Assembly (Propane/LP Gas)(See page 34)

1

24

116375-01

Plenum

1

 

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

25487

Lava Rock/Bag Assy

1

 

27253

Notice Label

1

 

55240

Vent Label

1

 

116388-01

Grate Finial

2

 

 

 

 

** Part not available for field replacement.

REFRACTORY BRICK PANELS

VC42N

VVC42N

VC42NH

VVC42NH

 

 

VC42P

VVC42P

VC42PH

VVC42PH

DESCRIPTION

QTY

 

 

 

 

 

 

111299-02

111299-01

111302-02

111302-01

Left Refractory Brick Panel

1

111297-02

111297-01

111300-02

111300-01

Rear Refractory Brick Panel

1

111298-02

111298-01

111301-02

111301-01

Right Refractory Brick Panel

1

 

 

 

 

 

 

 

 

 

 

 

 

116236-01B

www.desatech.com

Image 33
Contents For Your Safety For Your Safety What to do if YOU Smell GASSave this manual for future reference Safety Information Table of ContentsLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Vertical Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationFireplace Installation Venting InstallationInstalling Optional Blower Accessories Check GAS TypeBlower see Figure Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Checking GAS ConnectionsOr servicing. Correct all leaks at once Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver REMOVING/REPLACING Glass DoorRemoving Louver Panels Installing Lava Rock and Glowing Embers Cleaning Glass DoorRemoving Glass Doors For Your Safety Read Before Lighting Installing Brick Liner Models BL42DASA and BL42 DhasaOperating Fireplace Lighting InstructionsTo Turn OFF GAS Manual Lighting ProcedureTo Appliance Optional HAND-HELD Remote OperationManual Mode Safety FeaturesAuto Thermostatic Mode ON/OFF Series Model GhrcbPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingBrick Liner Models BL42DASA Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsModels VC42N, VC42P, VVC42N and VVC42P Series Illustrated Parts BreakdownKEY Part Number Description QTY Parts List19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01B Warranty Information

(V)VC42P SERIES, (V)VC42N SERIES specifications

The Desa (V)VC42P and (V)VC42N Series are advanced solutions in the HVAC and thermal control industry, designed to provide efficient climate management for various applications. These series are noted for their commitment to performance, reliability, and energy efficiency, making them popular choices among users looking for modern heating and ventilation systems.

One of the main features of the (V)VC42P and (V)VC42N Series is their state-of-the-art variable speed technology. This technology allows the units to adjust their output based on the specific heating or cooling needs of a space. By operating at different speeds, the systems can maintain a more consistent temperature while using less energy compared to traditional fixed-speed systems. This leads to significant cost savings and enhanced comfort for occupants.

Additionally, both series incorporate advanced control systems that can be easily integrated with smart home technologies. Users can remotely monitor and adjust their HVAC systems via mobile applications or voice-activated devices, facilitating greater control over their indoor climate. This compatibility with smart technologies not only enhances user experience but also contributes to energy conservation efforts by allowing for better management of usage patterns.

Another characteristic of the Desa (V)VC42P and (V)VC42N Series is their robust construction and design. Built with high-quality materials, these units demonstrate durability and reliability over time. The compact design of these systems allows for flexible installation options, making them suitable for various residential and commercial environments.

Moreover, the series prioritizes low noise operation, ensuring that the units run quietly without disturbing the peace in homes or workplaces. This feature is particularly essential in settings where noise control is critical, such as in offices, schools, or healthcare facilities.

In summary, the Desa (V)VC42P and (V)VC42N Series stand out in the HVAC market due to their variable speed technology, smart home compatibility, durable construction, and low noise operation. With their innovative features and characteristics, these systems are well-equipped to provide effective and efficient climate control solutions tailored to modern living and working environments.