Desa YGF33PRB, FPVF33NRA installation manual Wiring Diagram, Specifications, Logs

Page 22

22

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.)

Logs

Main Burner

WIRING DIAGRAM

SPECIFICATIONS

CLEANING AND

MAINTENANCE

Continued

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4, page 21.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 48). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet Hole

Figure 48 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 15 and 16, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the fireplace run- ning. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off fireplace and let cool. Remove blockage, blocked burner flame holes will create soot.

WIRING DIAGRAM

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

A

 

UT

O

OF

ON

F

 

Thermopile

SPECIFICATIONS

 

VYGF33NRB

 

FPVF33NRA

Btu (Variable)

20,000/30,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

 

 

VYGF33PRB

 

FPVF33PRA

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

 

For..com

110148-01B

Image 22
Contents Qqqq ¢¢¢¢ What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesUnpacking Product FeaturesLocal Codes AIR for Combustion and VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupIncluded with Mantel Accessory Installation ClearancesAssembling and Attaching Optional Brass Trim Conventional Fireplace Installation Placing Hearth Base Accessory Against WallActual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Gas ConnectionsFPVF33PRA Installing Remote Receiver Unit Optional Wireless HAND-HELD RemoteInstalling 9-VOLT Batteries Installing 9-Volt Battery in ReceiverOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Ghrc Series OperationBurner Primary AIR Holes Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerSpecifications Wiring DiagramLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Illustrated Parts Breakdown VYGF33PRBParts List KEY Part Number VYGF33PRB VYGF33NRB Description QTYFirebox VYGF33PRB VYGF33NRB Firebox VYGF33PRB & VYGF33NRB KEY Part Number Description QTYFPVF33PRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox FPVF33PRA FPVF33NRA Firebox FPVF33PRA & FPVF33NRA Accessories WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch GWMT1 Firebox Perimeter Brass Trim Accessory GA6090Service Hints Replacement PartsTechnical Service Parts Under WarrantyOwners Registration Form Postage Required 110148-01B Warranty Information