Desa FPVF33NRA, YGF33PRB installation manual Product Identification, Other gases

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

1.

This appliance is only for use with the type of gas indicated on

 

the rating plate. This appliance is not convertible for use with

 

other gases.

2.

Do not place propane/LP supply tank(s) inside any structure. Lo-

 

cate propane/LP supply tank(s) outdoors (propane/LP units only).

3.

If you smell gas

 

shut off gas supply

 

do not try to light any appliance

 

do not touch any electrical switch; do not use any phone in

 

 

your building

 

• immediately call your gas supplier from a neighbor’s phone.

 

 

Follow the gas supplier’s instructions

 

• if you cannot reach your gas supplier, call the fire department

4.

This fireplace shall not be installed in a bedroom or bathroom.

5.

Do not use this fireplace as a wood-burning fireplace. Use only

 

the logs provided with the fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in propane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (pro- pane/LP units only).

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

One Piece

Log Set

Optional

Remote

Control

I

H

 

O

NO

FF

6. Do not add extra logs or ornaments such as pine cones, ver-

miculite, or rock wool. Using these added items can cause soot-

Control Knobs

Remote Selector Switch (Optional)

 

ing. Do not add lava rock around base. Rock and debris could

 

fall into the control area of fireplace.

7.

To prevent the creation of soot, follow the instructions in Clean-

 

ing and Maintenance, pages 21 and 22.

8.

Before using furniture polish, wax, carpet cleaner, or similar

 

products, turn heater off. If heated, the vapors from these prod-

 

ucts may create a white powder residue within burner box or

 

on adjacent walls or furniture.

9.

This fireplace needs fresh air ventilation to run properly. This

 

fireplace has an Oxygen Depletion Sensing (ODS) safety

 

shutoff system. The ODS shuts down the fireplace if enough

 

fresh air is not available. See Air for Combustion and Ventila-

 

tion, pages 4 through 6. If fireplace keeps shutting off, see

 

Troubleshooting, pages 23 through 25.

10.

Do not run fireplace

 

where flammable liquids or vapors are used or stored

 

under dusty conditions

11.

Do not use this fireplace to cook food or burn paper or other

 

objects.

12.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service technician to in-

 

spect the fireplace and to replace any part of the control sys-

 

tem and any gas control which has been under water.

13.

Do not operate fireplace if any log is broken. Do not operate

 

fireplace if a log is chipped (dime-sized or larger).

14.

Turn fireplace off and let cool before servicing. Only a quali-

 

fied service person should service and repair fireplace.

Piezo Ignitor

Figure 1 - Log Base Assembly (VYGF33PRB Shown)

Top Louver

AssemblyTop Outer

Casing

Firebox

Hood

Firebox

Support

Blower Assembly (Optional)

Bottom

Louver

Assembly

Screen

Assembly

Figure 2 - Fireplace (VYGF33PRB Shown)

For morevisit www..com

110148-01B

Image 3
Contents What to do if YOU Smell GAS Qqqq ¢¢¢¢Safety Information Table of ContentsOther gases Product IdentificationAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeInstallation Clearances Included with Mantel AccessoryAssembling and Attaching Optional Brass Trim Placing Hearth Base Accessory Against Wall Conventional Fireplace InstallationActual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Installing GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Installing LogsFPVF33PRA Installing 9-Volt Battery in Receiver Optional Wireless HAND-HELD RemoteInstalling 9-VOLT Batteries Installing Remote Receiver UnitFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Ghrc Series Operation Inspecting BurnersOptional Blower Operation Pilot Flame PatternMain Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesWiring Diagram SpecificationsLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VYGF33PRB Illustrated Parts BreakdownKEY Part Number VYGF33PRB VYGF33NRB Description QTY Parts ListFirebox VYGF33PRB VYGF33NRB KEY Part Number Description QTY Firebox VYGF33PRB & VYGF33NRBFPVF33PRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox FPVF33PRA FPVF33NRA Firebox FPVF33PRA & FPVF33NRA Accessories Firebox Perimeter Brass Trim Accessory GA6090 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Parts Under Warranty Replacement PartsTechnical Service Service HintsOwners Registration Form Postage Required 110148-01B Warranty Information