Desa FPVF33PR Conventional Fireplace Installation, Minimum Wall and Ceiling Clearances see Figure

Page 11

INSTALLING

INSTALLATION CLEARANCES

Continued

WARNING ICONG 001WARNING

Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling Clearances (see Figure 7)

A.Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

MINIMUM CLEARANCE

Note: Clearances

42"

Side Wall - 16 " Cabinet and

are the same if

Face Mantel

 

using optional

 

Ceiling - 42" Corner Mantel

cabinet mantel or

 

Floor - 0"

built-in installation.

 

 

 

16"

 

 

Face or

 

 

Cabinet

 

 

Mantel

 

 

12"

 

 

Corner

 

 

Mantel

 

Figure 7 - Minimum Clearance to Wall and Ceiling

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.

WARNING

WARNING ICON

G 001

For conventional installation, it is recommended you use the cabinet mantel, corner mantel, face mantel, or hearth bases speci- fied in this manual. Surface clearances may not be sufficient with other cabinet mantels and hearth bases. This may create a fire hazard. See Accessories, pages 34 and 35 for correct mantels and hearth bases.

Note: The instructions below show installation using the cabinet mantel and the G3000F/G3001U hearth base accessories. The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor. The corner mantel and face mantel accessories cannot be installed with the G3000F/G3001U hearth base. You must install corner and face mantel directly on the floor. If mounting fireplace and cabinet mantel to the floor or using face mantel or corner mantel, an optional G3005 Slim Base kit may be installed.

1.Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc- tions are included with each accessory.

2.Install a properly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel

will cover it when installed (see Figure 8, page 12).

Continued

11

 

 

103280

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Fireplace LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallingCheck GAS Type Assembling Brass Trim Assembling and Attaching Brass TrimMinimum Wall and Ceiling Clearances see Figure Conventional Fireplace InstallationBreak off nailing flanges see with hammer or pliers BUILT-IN Fireplace Installation InstallingRough Opening for Installing in Corner Installing Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationExternal Regulator with Vent Pointing Down Installation Items Needed Connecting Fireplace to GAS SupplyAttaching Flexible Gas Lines Together Checking GAS ConnectionsQQQQQQQQ¢ ¢¢¢¢¢¢¢,Q¢ Pressure Testing Fireplace Gas ConnectionsInstalling Logs Split Oak Design Models Installing Fireplace Screen Operating Fireplace For Your Safety Read Before LightingFireplace OperatingManually-Controlled Models Variable Control Operation Pilot Flame Pattern Inspecting BurnersCorrect Front Burner Flame Pattern Front Burner Flame PatternLogs Cleaning and Maintenance Trouble ShootingTurn off fireplace and let cool before cleaning ODS/PILOT and BurnersCleaning and Mainte Maintenance, Trouble ShootingBuilding If you smell gasShut off gas supply Do not try to light any applianceParts Not Under Warranty Technical Service Hints Replacement PartsParts Under Warranty Verify proper operation after servicing Wiring DiagramsAccessories GM200F Walnut Finished GM201U Unfinished ¢Q, ¢QQQQ,,,, ¢ ¢ ¢ ¢QIllustrated Parts Breakdown Log Base Assembly Variable Manually Controlled Models Parts ListThermostat Controlled Models Log Base Assembly Thermostat Controlled Models Illustrated VSGF28PV/CSGF28PV VSGF28PTA/CSGF28PTA 103280 103280 Keep this Warranty Warranty Information

FPVF33PR specifications

The Desa FPVF33PR is a cutting-edge product that exemplifies innovation in modern design and functionality. This versatile device is engineered to cater to both practical needs and aesthetic preferences, making it a sought-after choice for consumers looking to enhance their living or working spaces.

One of the standout features of the Desa FPVF33PR is its advanced heating technology. Utilizing a powerful yet efficient heating system, this unit is capable of providing comfortable warmth while minimizing energy consumption. Its design is optimized for efficient heat distribution, ensuring that every corner of the room receives adequate warmth without the need for excessive energy use.

In addition to its heating capabilities, the FPVF33PR integrates intuitive smart technology. This feature allows for seamless control through various devices, including smartphones and smart home systems. Users can adjust settings remotely, monitor energy usage, and even set schedules for operation, which enhances both convenience and efficiency.

The design of the Desa FPVF33PR is another noteworthy characteristic. With a sleek and modern aesthetic, this unit can easily complement different interior styles, from contemporary to traditional. Crafted with high-quality materials, it promises durability and longevity, making it a sound investment for both homes and offices.

Safety is a paramount consideration in the design of the FPVF33PR. This unit is equipped with multiple safety features, including overheat protection and a tip-over switch, which ensures that it operates safely even in high-demand conditions. This focus on safety not only gives peace of mind to users but also signifies Desa's commitment to responsible manufacturing.

Furthermore, the FPVF33PR is user-friendly, with an easy-to-navigate control panel and clear indications for operation. This ease of use caters to a wide range of customers, from tech enthusiasts to those who prefer straightforward functionality.

Overall, the Desa FPVF33PR stands out in a crowded market with its combination of advanced technology, efficient performance, stylish design, and safety features. This product is designed to meet the diverse needs of modern users while providing exceptional value and reliability. Whether for heating a cozy living room or enhancing a workspace, the FPVF33PR is an exemplary choice that does not compromise on quality or performance.