Desa FPVF33PR installation manual Manually-Controlled Models

Page 24
C-clockwise

OPERATING FIREPLACE

Manually-Controlled Models

24

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

WARNING ICON

G 001

 

 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

WARNING ICON

G 001

You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE

During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information on above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

Ignitor Button

Control Knob

IGNITOR

Figure 30 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

5. Slightly depress and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 30, above).

Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.

103280

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Product Identification Features Local CodesUnpacking ProductAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Check GAS TypeElectrical Hookup Assembling and Attaching Brass Trim Assembling Brass TrimConventional Fireplace Installation Minimum Wall and Ceiling Clearances see FigureBreak off nailing flanges see with hammer or pliers Installing BUILT-IN Fireplace InstallationRough Opening for Installing in Corner Installing GAS Piping to Fireplace Location Installing Mantel Clearances for Built-In InstallationExternal Regulator with Vent Pointing Down Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Attaching Flexible Gas Lines TogetherPressure Testing Fireplace Gas Connections QQQQQQQQ¢ ¢¢¢¢¢¢¢,Q¢Installing Logs Split Oak Design Models Installing Fireplace Screen For Your Safety Read Before Lighting Operating FireplaceOperating FireplaceManually-Controlled Models Variable Control Operation Inspecting Burners Pilot Flame PatternFront Burner Flame Pattern Correct Front Burner Flame PatternCleaning and Maintenance Trouble Shooting Turn off fireplace and let cool before cleaningODS/PILOT and Burners LogsCleaning and Mainte Trouble Shooting Maintenance,If you smell gas Shut off gas supplyDo not try to light any appliance BuildingTechnical Service Hints Replacement Parts Parts Under WarrantyParts Not Under Warranty Wiring Diagrams Verify proper operation after servicingAccessories ¢Q, ¢QQQQ,,,, ¢ ¢ ¢ ¢Q GM200F Walnut Finished GM201U UnfinishedIllustrated Parts Breakdown Parts List Log Base Assembly Variable Manually Controlled ModelsThermostat Controlled Models Log Base Assembly Thermostat Controlled Models Illustrated VSGF28PV/CSGF28PV VSGF28PTA/CSGF28PTA 103280 103280 Warranty Information Keep this Warranty

FPVF33PR specifications

The Desa FPVF33PR is a cutting-edge product that exemplifies innovation in modern design and functionality. This versatile device is engineered to cater to both practical needs and aesthetic preferences, making it a sought-after choice for consumers looking to enhance their living or working spaces.

One of the standout features of the Desa FPVF33PR is its advanced heating technology. Utilizing a powerful yet efficient heating system, this unit is capable of providing comfortable warmth while minimizing energy consumption. Its design is optimized for efficient heat distribution, ensuring that every corner of the room receives adequate warmth without the need for excessive energy use.

In addition to its heating capabilities, the FPVF33PR integrates intuitive smart technology. This feature allows for seamless control through various devices, including smartphones and smart home systems. Users can adjust settings remotely, monitor energy usage, and even set schedules for operation, which enhances both convenience and efficiency.

The design of the Desa FPVF33PR is another noteworthy characteristic. With a sleek and modern aesthetic, this unit can easily complement different interior styles, from contemporary to traditional. Crafted with high-quality materials, it promises durability and longevity, making it a sound investment for both homes and offices.

Safety is a paramount consideration in the design of the FPVF33PR. This unit is equipped with multiple safety features, including overheat protection and a tip-over switch, which ensures that it operates safely even in high-demand conditions. This focus on safety not only gives peace of mind to users but also signifies Desa's commitment to responsible manufacturing.

Furthermore, the FPVF33PR is user-friendly, with an easy-to-navigate control panel and clear indications for operation. This ease of use caters to a wide range of customers, from tech enthusiasts to those who prefer straightforward functionality.

Overall, the Desa FPVF33PR stands out in a crowded market with its combination of advanced technology, efficient performance, stylish design, and safety features. This product is designed to meet the diverse needs of modern users while providing exceptional value and reliability. Whether for heating a cozy living room or enhancing a workspace, the FPVF33PR is an exemplary choice that does not compromise on quality or performance.