AIR FOR COMBUSTION AND VENTILATION

Continued

WARNING

WARNING ICON

G 001

If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

WARNING ICON

G 001

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills

Into Adjoining Room,

Room,

Or

Option 2

Option 1

Remove

8

Door into Adjoining Room, Option 3

12"

Figure 3 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

 

 

Outlet

 

 

 

Ventilated

 

 

 

 

 

Attic

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Attic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

,,,,QQQQ¢¢¢¢

To

 

 

 

 

Crawl

Inlet

 

 

Space

 

 

 

 

 

Inlet Air

Ventilated

 

 

 

Crawl Space

 

 

 

 

 

 

Figure 4 - Ventilation Air from Outdoors

103280

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Product Identification Features Local CodesUnpacking ProductAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallingCheck GAS Type Assembling and Attaching Brass Trim Assembling Brass TrimConventional Fireplace Installation Minimum Wall and Ceiling Clearances see FigureBreak off nailing flanges see with hammer or pliers Installing BUILT-IN Fireplace InstallationRough Opening for Installing in Corner Installing GAS Piping to Fireplace Location Installing Mantel Clearances for Built-In InstallationExternal Regulator with Vent Pointing Down Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Attaching Flexible Gas Lines TogetherPressure Testing Fireplace Gas Connections QQQQQQQQ¢ ¢¢¢¢¢¢¢,Q¢Installing Logs Split Oak Design Models Installing Fireplace Screen For Your Safety Read Before Lighting Operating FireplaceOperating FireplaceManually-Controlled Models Variable Control Operation Inspecting Burners Pilot Flame PatternFront Burner Flame Pattern Correct Front Burner Flame PatternCleaning and Maintenance Trouble Shooting Turn off fireplace and let cool before cleaningODS/PILOT and Burners LogsCleaning and Mainte Trouble Shooting Maintenance,If you smell gas Shut off gas supplyDo not try to light any appliance BuildingParts Not Under Warranty Technical Service Hints Replacement PartsParts Under Warranty Wiring Diagrams Verify proper operation after servicingAccessories ¢Q, ¢QQQQ,,,, ¢ ¢ ¢ ¢Q GM200F Walnut Finished GM201U UnfinishedIllustrated Parts Breakdown Parts List Log Base Assembly Variable Manually Controlled ModelsThermostat Controlled Models Log Base Assembly Thermostat Controlled Models Illustrated VSGF28PV/CSGF28PV VSGF28PTA/CSGF28PTA 103280 103280 Warranty Information Keep this Warranty

FPVF33PR specifications

The Desa FPVF33PR is a cutting-edge product that exemplifies innovation in modern design and functionality. This versatile device is engineered to cater to both practical needs and aesthetic preferences, making it a sought-after choice for consumers looking to enhance their living or working spaces.

One of the standout features of the Desa FPVF33PR is its advanced heating technology. Utilizing a powerful yet efficient heating system, this unit is capable of providing comfortable warmth while minimizing energy consumption. Its design is optimized for efficient heat distribution, ensuring that every corner of the room receives adequate warmth without the need for excessive energy use.

In addition to its heating capabilities, the FPVF33PR integrates intuitive smart technology. This feature allows for seamless control through various devices, including smartphones and smart home systems. Users can adjust settings remotely, monitor energy usage, and even set schedules for operation, which enhances both convenience and efficiency.

The design of the Desa FPVF33PR is another noteworthy characteristic. With a sleek and modern aesthetic, this unit can easily complement different interior styles, from contemporary to traditional. Crafted with high-quality materials, it promises durability and longevity, making it a sound investment for both homes and offices.

Safety is a paramount consideration in the design of the FPVF33PR. This unit is equipped with multiple safety features, including overheat protection and a tip-over switch, which ensures that it operates safely even in high-demand conditions. This focus on safety not only gives peace of mind to users but also signifies Desa's commitment to responsible manufacturing.

Furthermore, the FPVF33PR is user-friendly, with an easy-to-navigate control panel and clear indications for operation. This ease of use caters to a wide range of customers, from tech enthusiasts to those who prefer straightforward functionality.

Overall, the Desa FPVF33PR stands out in a crowded market with its combination of advanced technology, efficient performance, stylish design, and safety features. This product is designed to meet the diverse needs of modern users while providing exceptional value and reliability. Whether for heating a cozy living room or enhancing a workspace, the FPVF33PR is an exemplary choice that does not compromise on quality or performance.