Desa CFS24NVC VS30N, B, C installation manual Gas leak. See Warning statement at

Page 21

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Open window and ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 12)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Log set cycles to pilot, but room tempera- ture drops to a lower than ideal level before log set comes back on

1.Thermostat sensing bulb needs to be re- positioned

1.Reposition thermostat sensing bulb (see Optional Positioning of Thermostat Sensing Bulb, page 22)

www.desatech.com

104414

21

Image 21
Contents What to do if YOU Smell GAS Unvented VENT-FREE Natural GAS LOG HeaterDesa International Unvented Natural GAS LOG Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Vent-Free Operation OnlyMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off HeaterVariable Control Operation Inspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbReplacement Parts SpecificationsService Hints Technical ServiceVariable Manually Controlled Split OAK Models Illustrated Parts BreakdownVariable MANUALLY- Controlled Split OAK Models Parts ListDesa International Unvented Natural GAS LOG Heater VS18NTB VS24NTB VS30NTB THERMOSTAT- Controlled Split OAK ModelsAccessories 104414 International Warranty Information

CFS24NVC VS30N, B, C specifications

Desa CFS24NVC VS30N, B, C is a sophisticated heating solution designed to deliver comfort and efficiency in various settings. This series is particularly noted for its advanced features and technologies that cater to user needs while ensuring optimal performance.

One of the standout characteristics of the CFS24NVC series is its versatility in operation. Whether it is a larger commercial space or a cozy residential area, these heaters can adapt their output to suit different environments. The VS30N model, for instance, provides a strong heating capacity, making it ideal for workshops or larger living spaces. The adjustable settings allow users to match the heater's performance with the current requirements, promoting energy efficiency and cost savings.

Furthermore, the CFS24NVC series employs advanced heating technologies that enhance performance. The inclusion of ceramic heating elements enables rapid heat distribution, ensuring that spaces are warmed up quickly. This technology not only improves efficiency but also enhances comfort by providing consistent warmth throughout the room without cold spots.

In terms of design, the CFS24NVC VS30N, B, C models prioritize user-friendliness. They come equipped with intuitive controls, allowing for easy adjustments to temperature and settings. Many users appreciate the digital displays which provide real-time feedback on performance and help monitor energy consumption.

Safety is also a core feature of the CFS24NVC series. The units are fitted with multiple safety mechanisms, including overheating protection and tip-over switches, which automatically power down the heater in case of accidents. This ensures peace of mind for users, making them suitable for use in families with children or pets.

Moreover, the CFS24NVC series is engineered with durability in mind. Constructed from high-quality materials, these heaters are built to withstand daily wear and tear, ensuring longevity in performance.

In conclusion, the Desa CFS24NVC VS30N, B, C series stands out in the heating market for its combination of versatility, advanced heating technologies, user-friendly design, and robust safety features. This series is an excellent choice for consumers looking for reliable, efficient heating solutions suitable for diverse applications.