Desa B, C, CFS24NVC VS30N Minimum Noncombustible Material Clearances, If Using Mantel

Page 8

DESA INTERNATIONAL

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Minimum Noncombustible Material Clearances

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

If Not Using Mantel

Note: If using a mantel proceed to If Using Mantel. If not using a mantel, follow the information on this page.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8" up (for all mod- els). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

 

 

 

12" or more

Noncombustible material OK.

Between 8" and 12"

24" or 30" Models: Install fireplace hood accessory

 

 

 

(GA6050, GA6052, or GA6053, see Accessories,

 

 

 

page 28).

 

 

 

18" Model: Noncombustible material OK.

Less than 8"

Noncombustible material must be extended to at

 

 

 

least 8". See Between 8" and 12", above. If you

 

 

 

cannot extend material, you must operate heater

 

 

 

with flue damper open.

 

 

 

 

 

Heat Resistant

 

 

 

 

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

(A)

 

 

 

 

 

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

104414

Image 8
Contents Unvented VENT-FREE Natural GAS LOG Heater What to do if YOU Smell GASSafety Information Desa International Unvented Natural GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Vent-Free Operation OnlyIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Logs Lighting Instructions For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterVariable Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Variable Manually Controlled Split OAK ModelsParts List Variable MANUALLY- Controlled Split OAK ModelsDesa International Unvented Natural GAS LOG Heater THERMOSTAT- Controlled Split OAK Models VS18NTB VS24NTB VS30NTBAccessories 104414 Warranty Information International

CFS24NVC VS30N, B, C specifications

Desa CFS24NVC VS30N, B, C is a sophisticated heating solution designed to deliver comfort and efficiency in various settings. This series is particularly noted for its advanced features and technologies that cater to user needs while ensuring optimal performance.

One of the standout characteristics of the CFS24NVC series is its versatility in operation. Whether it is a larger commercial space or a cozy residential area, these heaters can adapt their output to suit different environments. The VS30N model, for instance, provides a strong heating capacity, making it ideal for workshops or larger living spaces. The adjustable settings allow users to match the heater's performance with the current requirements, promoting energy efficiency and cost savings.

Furthermore, the CFS24NVC series employs advanced heating technologies that enhance performance. The inclusion of ceramic heating elements enables rapid heat distribution, ensuring that spaces are warmed up quickly. This technology not only improves efficiency but also enhances comfort by providing consistent warmth throughout the room without cold spots.

In terms of design, the CFS24NVC VS30N, B, C models prioritize user-friendliness. They come equipped with intuitive controls, allowing for easy adjustments to temperature and settings. Many users appreciate the digital displays which provide real-time feedback on performance and help monitor energy consumption.

Safety is also a core feature of the CFS24NVC series. The units are fitted with multiple safety mechanisms, including overheating protection and tip-over switches, which automatically power down the heater in case of accidents. This ensures peace of mind for users, making them suitable for use in families with children or pets.

Moreover, the CFS24NVC series is engineered with durability in mind. Constructed from high-quality materials, these heaters are built to withstand daily wear and tear, ensuring longevity in performance.

In conclusion, the Desa CFS24NVC VS30N, B, C series stands out in the heating market for its combination of versatility, advanced heating technologies, user-friendly design, and robust safety features. This series is an excellent choice for consumers looking for reliable, efficient heating solutions suitable for diverse applications.