Desa FVF30N installation manual Connecting to GAS Supply, Gas Connection

Page 12

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

CSA Design-Certified

Equipment shutoff Valve

With 1/8" NPT Tap

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 21.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

 

Tee Joint

 

Sediment

Pipe

 

Trap

Nipple

3" Minimum

 

Cap

 

Approved Flexible Gas Hose (if allowed by local codes)

Gas Regulator

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Figure 13 - Gas Connection

* Minimum inlet pressure for purpose of input adjustment.

12

105191

Image 12
Contents OWNER’S Operation and Installation Manual Also DESIGN-CERTIFIED AS a Vented Decorative ApplianceWhat to do if YOU Smell GAS Patent PendingSafety Information Unvented Natural GAS LOG HeaterProduct Features Product IdentificationLocal Codes Unpacking AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type If Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyChimney Minimum Permanent Height ft Flue Opening sq. ins Installation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply Gas ConnectionPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Heat Majic One- Piece Log SetFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burners Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atCleaning and Maintenance Service HintsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleReplacement Parts AccessoriesSpecifications Illustrated Parts Breakdown Heat Majic FVF18N FVF24N FVF30NODS Pilot Parts List KEY Part Number for FVF18N FVF24N FVF30N Description QTYWarranty Information