Desa FVF30N installation manual Cleaning and Maintenance, Service Hints, Technical Service, Logs

Page 20

UNVENTED NATURAL GAS LOG HEATER

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 22).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 23). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

 

Injector Holder

Burner

(May Be Brass

or Aluminum

Tube

Depending on

 

 

Model)

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 22 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet

Hole

Figure 23 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 14 to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

You may feel your gas pressure is too low. If so, contact your local natural gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact Fireplace Manufacturers Incorporated’s Technical Service Depart- ment at 1-866-672-6040.

You can also visit DESA International’s Technical Service web site at www.desatech.com.

20

105191

Image 20
Contents OWNER’S Operation and Installation Manual Also DESIGN-CERTIFIED AS a Vented Decorative ApplianceWhat to do if YOU Smell GAS Patent PendingSafety Information Unvented Natural GAS LOG HeaterLocal Codes Unpacking Product FeaturesProduct Identification AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Minimum Noncombustible Material Clearances If Using MantelIf Not Using Mantel Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply Gas ConnectionChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Logs Installing Heat Majic One- Piece Log SetLighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Burners Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atCleaning and Maintenance Service HintsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleSpecifications Replacement PartsAccessories ODS Pilot Illustrated Parts BreakdownHeat Majic FVF18N FVF24N FVF30N Parts List KEY Part Number for FVF18N FVF24N FVF30N Description QTYWarranty Information