Desa VTD-24P-BTB Operating Appliance, For Your Safety Read Before Lighting, Lighting Instructions

Page 11

OPERATING APPLIANCE (REMOTE-READY MODELS)

For Your Safety Read Before Lighting

Lighting Instructions

11

OPERATING APPLIANCE

REMOTE-READY MODELS

 

Selector Switch in

Control Knob

OFF Position

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

NOTICE: During initial operation of new appliance, metallic components may emit an odor as paint and assembly compounds are heated and cure. Be sure to provide adequate fresh air if odors are detected.

WARNING: Damper handle will be hot if appliance has been running.

CAUTION: A mild gas flash may occur within 10 seconds of normal shutdown of this appliance. Re- main clear of the hearth area for the entire shutdown process to avoid possible injury.

O

 

IL T

O

P

F

N

F

 

O

 

OL

 

AUTO

 

 

 

OFF

 

 

HI

 

ON

 

 

Ignitor Button

Flame Adjustment Knob

Figure 13 - Control Knob and Ignitor Button Location, Remote Ready Units.

1.STOP! Read the safety information, starting in column 1, of this page.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in the OFF position.

4. Press in and turn control knob clockwise to the OFF position (see Figure 13).

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, starting in column 1 of this page. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise

to the PILOT position. Press in control knob for five (5) seconds (see Figure 13).

Note: You may be running this appliance for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 12.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

For more information, visit www.desatech.com

111826-02F

Image 11
Contents Ansi Z21.60-2003 CSA What to do if YOU Smell GASSafety Information Table of ContentsProduct Identification Local CodesAIR for Combustion and Ventilation Optional Remote Control AccessoriesProduct Features UnpackingVentilation AIR Determining FRESH-AIR Flow for Appliance LocationVentilation Air from Outdoors Installation Installation Items Needed Installing Appliance AssemblyConnecting to GAS Supply Checking GAS Connections Pressure Testing gas Supply Piping systemValve Pressure Testing Appliance Gas ConnectionsLighting Instructions For Your Safety Read Before LightingOperating Appliance To Turn OFF GAS to Appliance Manual Lighting ProcedureRemote Control Operation Burner Flame Pattern Cleaning and MaintenanceOperating Appliance Inspecting Burner Pilot Flame PatternObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Observed Problem Possible Cause VTD-18N-PDG/VTD-18N-BTB SpecificationsTechnical Service Wiring DiagramReplacement Parts Service HintsThis page Intentionally Left Blank Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Accessories Owners Registration Form Postage Required 111826-02F Warranty Information

VTD-24P-BTB, VTD-18P-BTB, VTD-24P-PDG, VTD-18N-BTB, VTD-18N-PDG specifications

Desa VTD-18N-BTB, VTD-18P-BTB, VTD-24P-PDG, VTD-24P-BTB, and VTD-18N-PDG are notable offerings in the realm of heaters, designed to provide efficient and effective heating solutions for various environments. Each model boasts a range of features and technologies that cater to different needs and preferences, promoting comfort and convenience.

Starting with the VTD-18N-BTB and VTD-18P-BTB, these models are engineered with a focus on reliability and performance. They come equipped with advanced heating technology that ensures rapid warmth distribution in residential or commercial spaces. Featuring adjustable heat settings, users can customize the temperature according to their comfort levels. The BTB designation indicates that these models possess a robust build quality, designed to withstand heavy use, while maintaining aesthetic appeal.

The VTD-24P-PDG and VTD-24P-BTB are designed for larger areas, delivering an increased heat output to accommodate more substantial spaces. These models incorporate energy-efficient technology, which aids in reducing overall energy consumption while providing consistent heat. Moreover, the programmable thermostat feature available in these units allows users to set specific heating schedules, significantly enhancing energy efficiency and convenience.

The VTD-18N-PDG stands out with its unique design and advanced features. This model combines a sleek and modern aesthetic with high functionality, making it suitable for contemporary interiors. It utilizes a dual-fuel technology option, providing the flexibility to operate on either gas or electric power, thus enhancing versatility in use. This feature is particularly beneficial for areas with fluctuating energy availability.

In terms of safety, all models incorporate essential safety mechanisms, including overheating protection and tip-over switches, ensuring peace of mind for users. The combination of portability and performance allows for seamless placement in various settings, from home living rooms to workshops and garages.

Overall, Desa's VTD series reflects a commitment to quality and innovation, promoting efficient heating solutions that cater to varying space and user requirements. These models are ideal for users seeking dependable heating options without compromising on style, functionality, or safety.