Desa FBPS Optional Blower Assembly Installation, Operating Optional Blower GA3500A

Page 12

®

UNVENTED (VENT-FREE) LOGMATE® FIREBOX

INSTALLATION

Continued

OPTIONAL BLOWER ASSEMBLY INSTALLATION

Proper installation of the blower system is required to insure that the maximum dis- charge of air can be delivered through the louvers on each side of the fireplace.

Note: You may perform this installation from either side of the fireplace. The lower door panels are removable from both sides of the firebox for better access.

1.Remove the blower assembly from the packaging and inspect the fan and wir- ing for damage. If any wiring is loose or damaged, return the assembly for exchange to your dealer or distributor.

2.Remove the 2 screws located at the top of the lower door panel. Slide door panel forward and up to remove tabs on panel from locating slots in firebox (see Figure 16).

3.Locate the two strips of hook & loop mounting strips on one side of the base of the lower compartment. Align the mounting strips on blower with mount- ing strips on base of firebox.

4.Install blower housing with exhaust out- let ports directed upwards along inner side wall of lower compartment. The blower outlets must be installed flush to the outer cabinet for air to flow properly.

5.Apply gentle force between hook & loop mounting strips to seat blower.

6.Remove control knob and lock nut from blower speed control shaft.

7.Place speed control shaft through 3/8" hole provided in right side of lower door panel removed in step 2.

8.While supporting speed control hous- ing, secure shaft in panel hole with lock nut. Place control knob on shaft.

9.Plug blower power cord into receptacle located in lower firebox compartment. Check to make sure there are no for- eign objects in blower wheel.

Operating Optional Blower GA3500A

Light your gas appliance with the blower off. After about 10 minutes, turn the blower on to deliver heated air out the top louvers. The blower features a variable control which allows you to select the blower speed you desire.

Note: Periodically check the louvers of the firebox and remove any dust, dirt, or ob- structions.

Receptacle

Blower

Speed

Control

Shaft

Lock Nut

Hook & Loop

Control Knob

Mounting Strips

Locating

Slot

Locating Holes

Door

Panel

10.Turn blower on and check for proper operation.

WARNING: Never touch the blower wheel while in operation.

11.Turn blower off before continuing.

12.Replace lower door panel by inserting tabs on bottom of panel into locating slots on firebox. Push door panel into an upright position and secure with screws removed in step 2.

Figure 18 - Installing Optional Blower GA3500A

Locating

Slot

Figure 16 - Removing Lower Door Panel

 

 

FIELD WIRE

 

 

BLK

BLK

INCOMING

 

 

 

 

 

 

120V AC

BLOWER

WHT

WHT (FUSE BOX

 

RECEPTACLE

 

OR

 

GRN

BREAKER)

 

 

 

VARIABLE

GRN

GND

 

ELECTRICAL RATING:

 

SPEED

CONNECTORS

CONTROL

120v, 60Hz, 0.9A

(NOT SUPPLIED)

 

 

Note: If any of the original wire must be replaced, it must be replaced with type TEW minimum 16GA copper wire rated at 105°C

Figure 17 - Optional Blower Wiring Diagram

12

105163

 

Image 12
Contents Unvented VENT-FREE What to do if YOU Smell GASSafety Information Local CodesUnpacking Product Features Product SpecificationsBlower Accessory OperationLocating Firebox AIR for Combustion and VentilationProviding Adequate Ventilation AIR for Combustion Ventilation Determining FRESH-AIR Flow for Firebox LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesMantel Clearances for Projected Built-In Installation ScreenFraming for Built-In Firebox Installation Top View Installing GAS Line Firebrick Floor Remove Knockout Thick LinerGAS Supply Testing HARD-WIRING FireboxElectrical Installation Optional Blower Assembly Installation Operating Optional Blower GA3500AOperating Guidelines & Maintenance Instructions Heat Deflective Hood InstallationReplacement Parts Technical ServiceParts Under Warranty Parts not Under WarrantyAccessories Polished Brass HoodFirebox TOP Blower GA3500AIllustrated BreakdownParts List KEY Part Number Fbps Description QTYWarranty Information

FBPS specifications

Desa FBPS, or Flexible Building Production System, is an innovative approach to construction that leverages advanced technologies to enhance efficiency, sustainability, and adaptability in building design and construction. This system is gaining traction in the industry due to its versatility and ability to integrate new methodologies suitable for various construction environments.

One of the main features of Desa FBPS is its modular design. This allows for the construction of buildings using pre-fabricated components, which can be assembled on-site with minimal disruption. This modularity not only speeds up the construction process but also reduces waste, as components are manufactured in a controlled environment where precision and quality can be more easily maintained.

Another significant characteristic of Desa FBPS is its use of smart technologies. The system incorporates IoT (Internet of Things) devices, enabling real-time monitoring of building conditions, energy consumption, and other critical parameters. This data-driven approach facilitates timely decision-making and maintenance, improving the overall longevity and functionality of the buildings.

Sustainability is a core principle of Desa FBPS. The system prioritizes eco-friendly materials and energy-efficient designs, often utilizing renewable energy sources and advanced insulation technologies. This focus on sustainability not only lowers the carbon footprint of construction but also results in long-term savings on energy costs for occupants.

Desa FBPS also emphasizes flexibility in design. Buildings constructed using this system can be easily expanded or modified to adapt to changing needs. This flexibility is particularly advantageous in urban areas where space is at a premium and evolving residential or commercial demands necessitate rapid responses from developers.

Additionally, the integration of Building Information Modeling (BIM) technology plays a crucial role in Desa FBPS. BIM allows for the visualization of a building throughout its lifecycle, facilitating better planning, collaboration among stakeholders, and improved project management.

In summary, Desa FBPS represents a paradigm shift in construction practices, characterized by modular design, smart technology integration, sustainability, and design flexibility. Its forward-thinking approach positions it as a leader in modern construction, addressing the growing demands for efficient and adaptable building solutions in a rapidly evolving world.