Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES installation manual Corner Installation

Page 11

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

11

VENTING INSTALLATION INSTRUCTIONS

Continued

CORNER INSTALLATION

Recommended Applications:

Corner ground floor installation

Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe)

Basement installation where one foot clearance from ground to termination is possible

 

Required

 

Vertical (V)

Vertical Pipe

Horizontal (H)

*46 1/4" min.

None

30" max.

57 1/4" min.

1 ft.

48" max.

69 1/4" min.

2 ft.

60" max.

81 1/4" min.

3 ft.

84" max.

93 1/4" min.

4 ft.

20' max.

* Ground Floor Corner Venting

Not to Exceed

(H) Limits

Square

Termination

Wall

Firestop

45°

Elbow

90° Elbow

As Required for (V)

See Chart for Pipe

Section Required

Not to Exceed

 

(H) Limits

Square

90° Elbow

Termination

Wall

 

Firestop

12" Minimum

45° Elbow

Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° Elbow

SNORKEL TERMINATION INSTALLATION

Recommended Applications:

Installations requiring a vertical rise on building exterior

Any installation using snorkel termination to achieve one foot above ground

Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination.

Snorkel

Snorkel

Termination

Termination

Wall

 

 

Firestop

 

90° Elbow

 

12"

 

Minimum

 

45°

12"

Elbow

 

Minimum

 

 

Adequate

 

Drainage

Snorkel Termination

12"

Minimum

Figure 16 - Snorkel Termination Configurations for Below Ground Installation

For morevisit www..com

111907-01B

Image 11
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Number Description High Altitude InstallationCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Attaching Speed Control to Firebox Blower Wiring Diagram Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemRemoving Louver Panels Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door REMOVING/REPLACING Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Optional Brick Liner Models BL42DASA, BL42DHASAInstalling Log No and Log No Optional Remote Control Wiring DiagramWall Switch Installation To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Models Illustrated Parts BreakdownDescription QTY Parts ListBurner Assembly for Models VV42ENA1, VV42ENSA1 KEY Part Number Description QTY Specifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

V)V42EPA(1) SERIES, V)V42ENA(1) SERIES specifications

The Desa V)V42EPA(1) and V)V42ENA(1) series represent a significant advancement in energy-efficient technologies, emphasizing performance, environmental sustainability, and user comfort. These innovative products have been meticulously designed for various applications, catering to residential, commercial, and industrial energy needs.

One of the standout features of the V)V42EPA(1) and V)V42ENA(1) series is their exceptional energy efficiency. Equipped with advanced integrated circuit technology, these devices optimize power consumption, reducing utility bills while minimizing carbon footprint. The utilization of cutting-edge materials in their construction ensures durability and long-lasting performance, making them an excellent investment for users seeking reliability.

The V)V42EPA(1) series integrates innovative heat exchange technology, allowing for superior thermal performance. This feature ensures quick heat delivery, enhancing overall efficiency while maintaining a comfortable indoor environment. Additionally, the models within this series are designed to operate quietly, making them suitable for settings where noise reduction is paramount, such as homes and offices.

Meanwhile, the V)V42ENA(1) series boasts advanced air filtration capabilities. These units incorporate sophisticated purification systems that significantly reduce allergens, dust, and other pollutants from the air. This feature not only contributes to improved indoor air quality but also facilitates a healthier living or working environment.

Another critical characteristic of both series is their user-friendly interface. They are equipped with intuitive control panels that simplify adjustments and enhance user experience. Remote control capabilities further allow users to manage settings from a distance, adding convenience to day-to-day operation.

The smart technology integration in the V)V42EPA(1) and V)V42ENA(1) series enables connectivity with smart home systems. This functionality allows users to monitor and control their energy consumption seamlessly, further promoting an eco-friendly lifestyle.

Both series are also designed with sustainability in mind. They utilize refrigerants with lower global warming potential, aligning with international environmental standards. This commitment to sustainability not only benefits the planet but also ensures compliance with regulatory requirements.

In conclusion, the Desa V)V42EPA(1) and V)V42ENA(1) series offer a blend of efficiency, comfort, and eco-friendliness. With their advanced technologies, user-centric design, and commitment to sustainability, these series set a benchmark in the energy solutions market, making them ideal choices for anyone looking to improve their energy management and overall indoor environment.