Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES Product Identification, Local Codes

Page 3

SAFETY INFORMATION

Continued

5.This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operat- ing fireplace.

8.Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, ser- vice, or repair this fireplace. Have fireplace inspected annu- ally by a qualified service person.

9.You must keep control compartments, burners, and circulat- ing air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding mate- rial, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 27.

11.Keep the area around your fireplace clear of combustible ma- terials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate.

14.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Ca- nadian Electrical Code, CSA C22.1.

15.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.

16.Do not operate fireplace if any log is broken.

17.Do not use a blower insert, heat exchanger insert, or other ac- cessory not approved for use with this fireplace.

18.Do not operate fireplace with glass door removed, cracked, or broken.

19.Provide adequate clearances around air openings.

SAFETY INFORMATION

3

PRODUCT IDENTIFICATION

LOCAL CODES

 

 

 

PRODUCT IDENTIFICATION

Upper Louver

 

Panel

Flue Collar

Nailing

 

Flange

 

 

Log

Glass

Set

 

Door

 

Assembly

 

 

Lava

 

Rock

Control

 

 

Valve

 

Grate

 

 

Lower

Glowing

Assembly

Louver

 

Panel

Embers

 

 

ON/OFF/REMOTE Switch

Blower Switch

 

(Optional Installation)

 

(Optional Installation)

 

 

Figure 1 - Victorian Direct-Vent Fireplace with Electronic Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

For morevisit www..com

111907-01B

Image 3
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Number Description High Altitude InstallationFireplace Installation Installing Optional Blower AccessoryCheck GAS Type Attaching Speed Control to Firebox Blower Wiring Diagram Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemRemoving Louver Panels Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door REMOVING/REPLACING Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Optional Brick Liner Models BL42DASA, BL42DHASAInstalling Log No and Log No Wiring Diagram Wall Switch InstallationOptional Remote Control To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Models Illustrated Parts BreakdownDescription QTY Parts ListBurner Assembly for Models VV42ENA1, VV42ENSA1 KEY Part Number Description QTY Specifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

V)V42EPA(1) SERIES, V)V42ENA(1) SERIES specifications

The Desa V)V42EPA(1) and V)V42ENA(1) series represent a significant advancement in energy-efficient technologies, emphasizing performance, environmental sustainability, and user comfort. These innovative products have been meticulously designed for various applications, catering to residential, commercial, and industrial energy needs.

One of the standout features of the V)V42EPA(1) and V)V42ENA(1) series is their exceptional energy efficiency. Equipped with advanced integrated circuit technology, these devices optimize power consumption, reducing utility bills while minimizing carbon footprint. The utilization of cutting-edge materials in their construction ensures durability and long-lasting performance, making them an excellent investment for users seeking reliability.

The V)V42EPA(1) series integrates innovative heat exchange technology, allowing for superior thermal performance. This feature ensures quick heat delivery, enhancing overall efficiency while maintaining a comfortable indoor environment. Additionally, the models within this series are designed to operate quietly, making them suitable for settings where noise reduction is paramount, such as homes and offices.

Meanwhile, the V)V42ENA(1) series boasts advanced air filtration capabilities. These units incorporate sophisticated purification systems that significantly reduce allergens, dust, and other pollutants from the air. This feature not only contributes to improved indoor air quality but also facilitates a healthier living or working environment.

Another critical characteristic of both series is their user-friendly interface. They are equipped with intuitive control panels that simplify adjustments and enhance user experience. Remote control capabilities further allow users to manage settings from a distance, adding convenience to day-to-day operation.

The smart technology integration in the V)V42EPA(1) and V)V42ENA(1) series enables connectivity with smart home systems. This functionality allows users to monitor and control their energy consumption seamlessly, further promoting an eco-friendly lifestyle.

Both series are also designed with sustainability in mind. They utilize refrigerants with lower global warming potential, aligning with international environmental standards. This commitment to sustainability not only benefits the planet but also ensures compliance with regulatory requirements.

In conclusion, the Desa V)V42EPA(1) and V)V42ENA(1) series offer a blend of efficiency, comfort, and eco-friendliness. With their advanced technologies, user-centric design, and commitment to sustainability, these series set a benchmark in the energy solutions market, making them ideal choices for anyone looking to improve their energy management and overall indoor environment.