Desa (V)V36N-B SERIES, VV36NC1 SERIES Troubleshooting, Observed Problem, Possible Cause, Remedy

Page 29
TROUBLESHOOTING

TROUBLESHOOTING

29

TROUBLESHOOTING

Note: For additional help, visit DESA’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a quali- fied service person should service and repair heater.

POSSIBLE CAUSECAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor. Nut is located behind the mounting bracket

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Gas control knob not in PILOT position

2.

Turn gas control knob to PILOT position

 

3.

Gas control knob not pressed in while

3.

Press in gas control knob while in PILOT

 

 

in PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is re-

 

 

 

 

moved

 

5.

Depleted gas supply (propane/LP models

5.

Contact local propane/LP gas company

 

 

only)

 

 

 

6.

Pilot is clogged

6.

Clean pilot (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas control

 

 

 

 

 

Pilot lights but flame goes out when control

1.

Gas control knob not fully pressed in

1.

Press in gas control knob fully

knob is released

2.

Gas control knob not pressed in long

2.

After pilot lights, keep gas control knob

 

 

enough

 

pressed in 30 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local natural or propane/LP

 

 

which allows thermocouple to cool,

 

gas company

 

 

causing pilot flame to go out. This prob-

 

B) Clean pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 28) or replace pi-

 

 

the following:

 

lot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged pilot

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten

 

 

trol valve

 

1/4 turn more

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

REMEDYFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111252-01E

Image 29
Contents FOR YOUR SAFETY OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not touch any electrical switchSAFETY INFORMATION TABLE OF CONTENTSLOCAL CODES PRODUCT IDENTIFICATIONContinued SAFETY INFORMATIONLOCATION AND SPACE REQUIREMENTS PRODUCT FEATURESPRE-INSTALLATION PREPARATION FRAMING AND FINISHING CLEARANCESPRE-INSTALLATION PREPARATION ContinuedD E B L LOCATION OF TERMINATION CAPV G V A LOCATION OF TERMINATION CAPINSTALLATION PRECAUTIONS VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Installation INSTALLATION PLANNINGVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSFigure 10 - Installing Horizontal Vent Cap ContinuedVENTING INSTALLATION INSTRUCTIONS Horizontal Termination ConfigurationsInstallation using cabinet surrounds NOT FOR CORNER INSTALLATIONRecommended Applications VENTING INSTALLATION INSTRUCTIONSContinued Continued VENTING INSTALLATION INSTRUCTIONSVenting with Two 90 Elbows Venting with Two 90 ElbowsFlat Ceiling Installation INSTALLATION FOR VERTICAL TERMINATIONVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS Vertical Termination ConfigurationsContinued Venting with Two 90 ElbowsPARTS LISTS FOR VENTING KITS AND COMPONENTS HIGH ALTITUDE INSTALLATIONDESA 5/8 Pipe & Vent Kits VENTING INSTALLATION INSTRUCTIONSINSTALLING OPTIONAL BLOWER ACCESSORIES FIREPLACE INSTALLATIONModel BK Installation CHECK GAS TYPEContinued Model BKT InstallationFIREPLACE INSTALLATION Blower Wiring Diagram INSTALLING GAS PIPING TO FIREPLACE LOCATIONFIREPLACE INSTALLATION ContinuedCONNECTING FIREPLACE TO GAS SUPPLY CHECKING GAS CONNECTIONSInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2FIREPLACE INSTALLATION ContinuedFIREPLACE INSTALLATION Installing Remote ReceiverContinued NOTICE Use only alkaline batteries not includedREMOVING/REPLACING GLASS DOOR Cleaning Glass DoorRemoving Louver Panels Removing Glass Doors11.Close top and bottom louvers FIREPLACE INSTALLATIONContinued Continued INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERSFIREPLACE INSTALLATION PROCEDURE FOR YOUR SAFETY READ BEFORE LIGHTINGTO TURN OFF GAS TO APPLIANCEOPERATING FIREPLACE Safety FeaturesREMOTE OPERATION AND CGHRCTBPILOT ASSEMBLY OPERATING OPTIONAL BLOWER ACCESSORYINSPECTING BURNERS OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTATGLASS DOOR CLEANING AND MAINTENANCEPILOT AND BURNERS LOGSOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYTROUBLESHOOTING REMEDYOBSERVED PROBLEM ContinuedOBSERVED PROBLEM TROUBLESHOOTINGContinued POSSIBLE CAUSEMODELS VV36N-B, VV36P-B,VV36NC1, VV36PC1 ILLUSTRATED PARTS BREAKDOWNVV36NSC1, VV36PSC1, VV36PHC1, VV36NHC1 AND CHDV36NR-CPARTS LIST PARTS LISTVV36N-B VV36NS-BILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELSILLUSTRATED PARTS BREAKDOWN Models VV36N-B, VV36P-B,VV36NC1, VV36PC1PARTS LIST PARTS LISTPART NUMBERSERVICE HINTS REPLACEMENT PARTSTECHNICAL SERVICE SPECIFICATIONSvisit www OWNERS REGISTRATION FORMFor more TAPE Postage RequiredTAPE 111252-01EFLEXIBLE GAS LINE CONNECTOR - GA5081 ACCESSORIESWALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown MANUAL BLOWER KIT - BKWARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACE