Desa CHDV36NR-C Remedy, Troubleshooting, Continued, Observed Problem, Possible Cause

Page 30
REMEDY

30

TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 28) or replace burner orifice

 

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

 

company

 

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads

 

 

 

properly connected

 

 

 

 

 

4.

Thermopile is defective

4.

Replace thermopile

 

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

 

company

 

 

2.

Burner porting or orifice clogged

2.

Clean burner (see Cleaning and Main-

 

 

 

 

 

tenance, page 28) or replace burner orifice

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 28) or replace burner orifice

 

 

2.

Damaged burner

2.

Replace damaged burner

 

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

and logs curing

 

operation

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning gas control knob to HI position

1.

Turn gas control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

 

pane/LP or natural gas company

 

 

3.

Dirty or partially clogged burner orifice

3.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 28) or replace burner orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

 

not excessively impinge on it

 

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

 

any type of material

 

 

 

 

 

Fireplace produces a clicking/ticking noise

1.

Metal expanding while heating or con-

1.

This is common. If noise is excessive,

just after burners are lit or shut off

 

tracting while cooling

 

contact qualified service person

 

 

 

 

 

Remote does not function

1.

Battery is not installed or battery power

1.

Replace 9-volt batteries in receiver and

 

 

 

is low

 

remote control

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111252-01E

Image 30
Contents FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY Do not touch any electrical switchTABLE OF CONTENTS SAFETY INFORMATIONContinued PRODUCT IDENTIFICATIONLOCAL CODES SAFETY INFORMATIONPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS PRE-INSTALLATION PREPARATION CLEARANCESFRAMING AND FINISHING ContinuedV G V A LOCATION OF TERMINATION CAPD E B L LOCATION OF TERMINATION CAPVENTING INSTALLATION INSTRUCTIONS INSTALLATION PRECAUTIONSVENTING INSTALLATION INSTRUCTIONS INSTALLATION PLANNINGHorizontal Termination Installation ContinuedFigure 10 - Installing Horizontal Vent Cap VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedInstallation using cabinet surrounds Horizontal Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS NOT FOR CORNER INSTALLATIONVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS INSTALLATION FOR VERTICAL TERMINATIONFlat Ceiling Installation ContinuedContinued Vertical Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS Venting with Two 90 ElbowsDESA 5/8 Pipe & Vent Kits HIGH ALTITUDE INSTALLATIONPARTS LISTS FOR VENTING KITS AND COMPONENTS VENTING INSTALLATION INSTRUCTIONSModel BK Installation FIREPLACE INSTALLATIONINSTALLING OPTIONAL BLOWER ACCESSORIES CHECK GAS TYPEModel BKT Installation FIREPLACE INSTALLATIONContinued FIREPLACE INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONBlower Wiring Diagram ContinuedInstallation Items Needed CHECKING GAS CONNECTIONSCONNECTING FIREPLACE TO GAS SUPPLY Pressure Testing Gas Supply Piping SystemFIREPLACE INSTALLATION INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2Pressure Testing Fireplace Gas Connections ContinuedContinued Installing Remote ReceiverFIREPLACE INSTALLATION NOTICE Use only alkaline batteries not includedRemoving Louver Panels Cleaning Glass DoorREMOVING/REPLACING GLASS DOOR Removing Glass DoorsFIREPLACE INSTALLATION Continued11.Close top and bottom louvers INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS FIREPLACE INSTALLATIONContinued TO TURN OFF GAS FOR YOUR SAFETY READ BEFORE LIGHTINGPROCEDURE TO APPLIANCEREMOTE OPERATION Safety FeaturesOPERATING FIREPLACE AND CGHRCTBINSPECTING BURNERS OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTATPILOT AND BURNERS CLEANING AND MAINTENANCEGLASS DOOR LOGSPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYOBSERVED PROBLEM REMEDYTROUBLESHOOTING ContinuedContinued TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEVV36NSC1, VV36PSC1, VV36PHC1, VV36NHC1 AND ILLUSTRATED PARTS BREAKDOWNMODELS VV36N-B, VV36P-B,VV36NC1, VV36PC1 CHDV36NR-CVV36N-B PARTS LISTPARTS LIST VV36NS-BILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELSILLUSTRATED PARTS BREAKDOWN Models VV36N-B, VV36P-B,VV36NC1, VV36PC1PART PARTS LISTPARTS LIST NUMBERTECHNICAL SERVICE REPLACEMENT PARTSSERVICE HINTS SPECIFICATIONSOWNERS REGISTRATION FORM For morevisit www TAPE Postage RequiredTAPE 111252-01EWALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown ACCESSORIESFLEXIBLE GAS LINE CONNECTOR - GA5081 MANUAL BLOWER KIT - BKLIMITED WARRANTY DIRECT-VENTFIREPLACE WARRANTY INFORMATION