Desa CHDV36NR-C Venting Installation Instructions, Continued, Installing Horizontal Vent Cap

Page 9
Figure 10 - Installing Horizontal Vent Cap

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

9

VENTING INSTALLATION INSTRUCTIONS

Continued

(Noncombustible Exterior) WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exte- rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal be- tween it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the stand- off. Apply non-hardening mastic around outside edge of stand- off. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material.

7.Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12).

8.Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4".

Vent Cap

Wood Screw

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Cut Siding Away to Fit Standoff

Standoff

Wood Screw

Manual backgroundVent Cap

Screws

Apply Mastic

to All Four Sides

Figure 11 - Installing Siding Standoff (Combustible Exterior Wall)

Interior Wall

Manual backgroundSurface

Wall

Manual background Firestop

Vent Cap

Horizontal

(Horizontal

Vent Pipe

Termination)

 

Screw

Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111252-01E

Image 9
Contents FOR YOUR SAFETY OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not touch any electrical switchSAFETY INFORMATION TABLE OF CONTENTSLOCAL CODES PRODUCT IDENTIFICATIONContinued SAFETY INFORMATIONPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS FRAMING AND FINISHING CLEARANCESPRE-INSTALLATION PREPARATION ContinuedD E B L LOCATION OF TERMINATION CAPV G V A LOCATION OF TERMINATION CAPINSTALLATION PRECAUTIONS VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Installation INSTALLATION PLANNINGVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSFigure 10 - Installing Horizontal Vent Cap ContinuedVENTING INSTALLATION INSTRUCTIONS Horizontal Termination ConfigurationsInstallation using cabinet surrounds NOT FOR CORNER INSTALLATIONVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications Continued VENTING INSTALLATION INSTRUCTIONSVenting with Two 90 Elbows Venting with Two 90 ElbowsFlat Ceiling Installation INSTALLATION FOR VERTICAL TERMINATIONVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS Vertical Termination ConfigurationsContinued Venting with Two 90 ElbowsPARTS LISTS FOR VENTING KITS AND COMPONENTS HIGH ALTITUDE INSTALLATIONDESA 5/8 Pipe & Vent Kits VENTING INSTALLATION INSTRUCTIONSINSTALLING OPTIONAL BLOWER ACCESSORIES FIREPLACE INSTALLATIONModel BK Installation CHECK GAS TYPEModel BKT Installation FIREPLACE INSTALLATIONContinued Blower Wiring Diagram INSTALLING GAS PIPING TO FIREPLACE LOCATIONFIREPLACE INSTALLATION ContinuedCONNECTING FIREPLACE TO GAS SUPPLY CHECKING GAS CONNECTIONSInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2FIREPLACE INSTALLATION ContinuedFIREPLACE INSTALLATION Installing Remote ReceiverContinued NOTICE Use only alkaline batteries not includedREMOVING/REPLACING GLASS DOOR Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorsFIREPLACE INSTALLATION Continued11.Close top and bottom louvers INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS FIREPLACE INSTALLATIONContinued PROCEDURE FOR YOUR SAFETY READ BEFORE LIGHTINGTO TURN OFF GAS TO APPLIANCEOPERATING FIREPLACE Safety FeaturesREMOTE OPERATION AND CGHRCTBPILOT ASSEMBLY OPERATING OPTIONAL BLOWER ACCESSORYINSPECTING BURNERS OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTATGLASS DOOR CLEANING AND MAINTENANCEPILOT AND BURNERS LOGSOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYTROUBLESHOOTING REMEDYOBSERVED PROBLEM ContinuedOBSERVED PROBLEM TROUBLESHOOTINGContinued POSSIBLE CAUSEMODELS VV36N-B, VV36P-B,VV36NC1, VV36PC1 ILLUSTRATED PARTS BREAKDOWNVV36NSC1, VV36PSC1, VV36PHC1, VV36NHC1 AND CHDV36NR-CPARTS LIST PARTS LISTVV36N-B VV36NS-BILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELSILLUSTRATED PARTS BREAKDOWN Models VV36N-B, VV36P-B,VV36NC1, VV36PC1PARTS LIST PARTS LISTPART NUMBERSERVICE HINTS REPLACEMENT PARTSTECHNICAL SERVICE SPECIFICATIONSOWNERS REGISTRATION FORM For morevisit www TAPE Postage RequiredTAPE 111252-01EFLEXIBLE GAS LINE CONNECTOR - GA5081 ACCESSORIESWALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown MANUAL BLOWER KIT - BKWARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACE