Desa (V)VC36NE Series installation manual Vertical, 30 max, Snorkel Termination Minimum

Page 11

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

11

VENTING INSTALLATION INSTRUCTIONS Continued

CORNER INSTALLATION

Recommended Applications:

Corner ground floor installation

Ground floor installation where pipe vents horizontally through wall

 

(over 12" horizontal pipe)

 

Vertical (V)

Required

Vertical (V)

Vertical Pipe

Horizontal (H)

*43 1/2" min.

None

30" max.

54 1/2" min.

1 ft.

48" max.

66 1/2" min.

2 ft.

60" max.

78 1/2" min.

3 ft.

84" max.

90 1/2" min.

4 ft.

20' max.

* Ground Floor Corner Venting

Basement installation where one foot clearance from ground to

 

termination is possible

Not to Exceed (H) Limits

90° Elbow

Square Termination

Not to Exceed

(H) Limits

Square Termination

Wall

Firestop

90° Elbow

As Required for (V)

See Chart for Pipe

Section Required

45° Elbow

Wall Firestop

45° Elbow

12" Minimum

Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° Elbow

SNORKEL TERMINATION INSTALLATION

Recommended Applications:

Installations requiring a vertical rise on building exterior

Any installation using snorkel termination to achieve one foot above ground

Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If install-

ing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel

termination (see Figure 16). Do not back fill around snorkel termination.

 

 

 

Snorkel

Snorkel

 

 

Termination

 

 

Termination

 

 

 

 

Wall

 

 

 

 

90°

Elbow

Firestop

 

 

 

12"

 

 

 

Minimum

45°

 

 

 

 

12"

 

Elbow

 

 

 

 

Minimum

 

 

 

 

Adequate

 

 

Drainage

 

Figure 16 - Snorkel Termination Configurations for Below Ground Installation

 

 

Snorkel Termination

12" Minimum

116235-01A

www.desatech.com

Image 11
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsBlower Safety Information Product IdentificationLocal Codes Control ValveLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation 681/2 ClearancesFraming and Finishing 35 3/4 133/4 10 3/8 49 5/8Termination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsCenter Installation PlanningHorizontal Termination Installation Male Female Slots Locking LugsVent Pipe Vent Cap Wood ScrewInterior Wall Surface Firestop Vent Cap HorizontalHorizontal Termination Configurations Snorkel Termination Minimum Vertical30 max Venting with Two 90 Elbows If area above is a room or Installation for Vertical TerminationFlat Ceiling Installation Roof Flashing Wall Strap Elbow Ceiling FirestopElbow Into inner collar fireplace as shown Vertical Termination ConfigurationsHigh Altitude Installation Desa 5/8 Pipe & Vent Kits Venting InstallationFireplace Installation Check GAS Type Installing Optional Blower AccessoryModel BKT Installation Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Removing Louver Panels Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass Door Installing Lava Rock and Glowing EmbersCleaning Glass Door Optional Remote Control Installing Brick Liner Models BL36DASA and BL36DHASAWall Switch Installation Lighting Instructions Wiring DiagramFor Your Safety Read Before Lighting Operating FireplaceOperation Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance Optional RemoteLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Parts Under Warranty Replacement PartsService Hints Technical ServiceSpecifications Models VC36NE, VVC36NE, VC36PE and VVC36PE Illustrated Parts BreakdownKEY Part Number Description QTY Parts List19 18 2827 116235-01A KEY Part Number Description Accessories Date Purchased Serial Number BrandModel Industrial Drive Box Bowling Green, KY 116235-01A Industrial Drive P.O. Box Warranty InformationModel Serial No Date Purchased

(V)VC36NE Series specifications

The Desa (V)VC36NE Series is a revolutionary heating solution designed for both residential and commercial application. This series combines advanced technologies with user-friendly features, making it a versatile option for consumers looking for reliable and efficient heating solutions.

One of the standout features of the VC36NE Series is its high-efficiency heating capabilities. Utilizing cutting-edge technology, this series achieves energy efficiency ratings that surpass traditional heating systems. This means that users can enjoy a comfortable indoor environment while significantly reducing their energy consumption and costs.

Another key characteristic of the VC36NE Series is its compact design. The sleek and modern aesthetics allow it to blend seamlessly into various interior designs while occupying minimal space. This makes it ideal for smaller homes or apartments where every square inch counts. The unit's lightweight construction also allows for easy installation, which can be completed by professionals or even handy homeowners.

The Desa VC36NE Series is equipped with advanced control features that provide users with full command over their heating system. A digital thermostat ensures accurate temperature regulation, allowing users to set their desired comfort level with precision. Additionally, the unit includes programmable settings, giving users the ability to create customized heating schedules tailored to their lifestyle.

Safety is paramount in the design of the VC36NE Series. It incorporates multiple safety features, including overheat protection and flame failure devices, ensuring peace of mind while the unit is in operation. This makes it a suitable option for families with children or pets.

In terms of modernization, the VC36NE Series often integrates smart technology, allowing users to connect the heating system to their smartphones or smart home networks. This feature enables remote control of heating schedules from anywhere, enhancing convenience and energy management.

Durability is another hallmark of the Desa VC36NE Series. Constructed with high-quality materials, the unit is designed to withstand the rigors of daily use over long periods. This robust construction ensures that users receive a reliable heating solution that will serve them for years to come.

In conclusion, the Desa (V)VC36NE Series stands out for its efficiency, compact design, advanced controls, safety features, connectivity, and durability. It is an exemplary choice for anyone seeking a modern heating solution that meets both performance and aesthetic requirements.