Desa (V)VC36NE Series Cleaning Maintenance, Glass Door, Pilot and Burners, Logs, Venting System

Page 25

CLEANING AND MAINTENANCE

Glass Door

Pilot and Burners

Logs

Venting System

25

CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate- rial, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

WARNING: Do not use abrasive cleaners as this maydamageglass.Useanonabrasivehouseholdglass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circum- stances present. Refer to Removing/Replacing Glass Door on page 20 of this manual when removing glass door for cleaning.

WARNING: Only parts supplied by the manu- facturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 28). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION:Wearglovesandsafetyglasseswhilehan- dling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 20). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 28 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 20 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

LOGS

If you remove logs for cleaning, refer to Installing Lava Rock and Glowing Embers, page 21, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 28.

Replace ember material periodically as needed. See Replacement Parts on page 28.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Re- move any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

116235-01A

www.desatech.com

Image 25
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsLocal Codes Safety Information Product IdentificationControl Valve BlowerPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing Clearances35 3/4 133/4 10 3/8 49 5/8 681/2Termination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningMale Female Slots Locking Lugs CenterInterior Wall Surface Firestop Vent Cap Vent Cap Wood ScrewHorizontal Vent PipeHorizontal Termination Configurations 30 max VerticalSnorkel Termination Minimum Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationRoof Flashing Wall Strap Elbow Ceiling Firestop If area above is a room orElbow Into inner collar fireplace as shown Vertical Termination ConfigurationsHigh Altitude Installation Fireplace Installation Check GAS Type Venting InstallationInstalling Optional Blower Accessory Desa 5/8 Pipe & Vent KitsModel BKT Installation Fireplace InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections REMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Door Wall Switch Installation Installing Brick Liner Models BL36DASA and BL36DHASAOptional Remote Control For Your Safety Read Before Lighting Wiring DiagramOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Operating Optional Blower AccessoryOptional Remote OperationGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Service Hints Replacement PartsTechnical Service Parts Under WarrantySpecifications Models VC36NE, VVC36NE, VC36PE and VVC36PE Illustrated Parts BreakdownKEY Part Number Description QTY Parts List19 18 2827 116235-01A KEY Part Number Description Accessories Model BrandDate Purchased Serial Number Industrial Drive Box Bowling Green, KY 116235-01A Model Serial No Date Purchased Warranty InformationIndustrial Drive P.O. Box

(V)VC36NE Series specifications

The Desa (V)VC36NE Series is a revolutionary heating solution designed for both residential and commercial application. This series combines advanced technologies with user-friendly features, making it a versatile option for consumers looking for reliable and efficient heating solutions.

One of the standout features of the VC36NE Series is its high-efficiency heating capabilities. Utilizing cutting-edge technology, this series achieves energy efficiency ratings that surpass traditional heating systems. This means that users can enjoy a comfortable indoor environment while significantly reducing their energy consumption and costs.

Another key characteristic of the VC36NE Series is its compact design. The sleek and modern aesthetics allow it to blend seamlessly into various interior designs while occupying minimal space. This makes it ideal for smaller homes or apartments where every square inch counts. The unit's lightweight construction also allows for easy installation, which can be completed by professionals or even handy homeowners.

The Desa VC36NE Series is equipped with advanced control features that provide users with full command over their heating system. A digital thermostat ensures accurate temperature regulation, allowing users to set their desired comfort level with precision. Additionally, the unit includes programmable settings, giving users the ability to create customized heating schedules tailored to their lifestyle.

Safety is paramount in the design of the VC36NE Series. It incorporates multiple safety features, including overheat protection and flame failure devices, ensuring peace of mind while the unit is in operation. This makes it a suitable option for families with children or pets.

In terms of modernization, the VC36NE Series often integrates smart technology, allowing users to connect the heating system to their smartphones or smart home networks. This feature enables remote control of heating schedules from anywhere, enhancing convenience and energy management.

Durability is another hallmark of the Desa VC36NE Series. Constructed with high-quality materials, the unit is designed to withstand the rigors of daily use over long periods. This robust construction ensures that users receive a reliable heating solution that will serve them for years to come.

In conclusion, the Desa (V)VC36NE Series stands out for its efficiency, compact design, advanced controls, safety features, connectivity, and durability. It is an exemplary choice for anyone seeking a modern heating solution that meets both performance and aesthetic requirements.