TROUBLESHOOTING

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

15

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot will not stay lit

1.

Defective thermocouple

1.

Check pilot flame. It must impinge on

 

 

 

 

thermocouple

 

 

 

2.

Clean or adjust pilot for maximum flame

 

 

 

 

impingement on thermocouple

 

 

 

3.

Ensure the connection between valve

 

 

 

 

and thermocouple are tight and secure

 

 

 

4.

Check thermocouple with millivolt

 

 

 

 

meter. Take reading at thermocouple ter-

 

 

 

 

minals of gas valve with remote control

 

 

 

 

off. It should read 18 millivolts mini-

 

 

 

 

mum. Replace faulty thermocouple if

 

 

 

 

reading is below specified minimum

 

 

 

 

 

Pilot lit but no flame on burner

1.

Remote or wires defective

1.

Check remote wires for proper connec-

 

 

 

 

tions. Place jumper wire across termi-

 

 

 

 

nals at remote control. If burner comes

 

 

 

 

on, replace remote. If okay, place jumper

 

 

 

 

wire across remote control at valve. If

 

 

 

 

burner comes on, wires are faulty or con-

 

 

 

 

nections are bad

 

2.

Thermopile not generating sufficient

2.

Check thermopile with millivolt meter.

 

 

milivoltage

 

Take reading at thermopile terminals of

 

 

 

 

gas valve with remote control off. It

 

 

 

 

should read 325 millivolts minimum.

 

 

 

 

Replace thermopile if reading is below

 

 

 

 

specified minimum

 

3.

Plugged burner orifice

3.

Check burner orifice for stoppage and

 

 

 

 

remove

Frequent pilot outage

1. Pilot flame may be too low or blowing

 

(high) causing safety pilot to “drop out”

1.Clean and/or adjust pilot flame for maximum flame impingement on thermocouple

For..com

111916-01C

Image 15
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Introduction Table of ContentsMantel Clearances PRE-INSTALLATION PreparationSelecting Location Clearances to CombustiblesFraming Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Venting Installation PrecautionsVenting Installation Electrical Hookup and Remote Receiver Diagram GAS Supply TestingGAS Line HOOK-UP Pilot AdjustmentRemoving Glass Panel Installing LOG SETModel CD42M-A Series Burner Flame Adjustment Decorative FacingFace Extension for Model CD32M only Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Operation GuidelinesConverting Fireplace from Natural GAS to PROPANE/LP GAS Converting PilotTo Turn OFF GAS To Appliance Converting Control Valve Installing New Parts for Gas Control Valve ConversionObserved Problem Possible Cause Remedy TroubleshootingIllustrated Parts Breakdown Models CD32MCD36M-A Series Models CD32M CD36M-A Series Parts ListModel CD42M-A Not a field replaceable part Wiring Diagram SpecificationsMillivolt Accessory and Replacement PartsNot a UPC

CD32M (-1)(-2) specifications

Desa CD32M (-1)(-2) is a cutting-edge technology designed to meet the demands of modern applications, particularly in the realm of telecommunications and data processing. This sophisticated dual-mode digital system offers versatility and efficiency, making it suitable for various industries including finance, healthcare, and manufacturing.

One of the main features of the Desa CD32M is its advanced processing capability. With a dual-core architecture, it can handle multiple tasks simultaneously, greatly enhancing performance in complex environments. This multi-threading capability allows for improved response times and higher productivity, which is critical for applications that require real-time data analysis and processing.

The Desa CD32M incorporates innovative technologies such as dynamic power management and adaptive processing algorithms. These technologies enable the system to efficiently allocate resources based on task priority, minimizing energy consumption without sacrificing performance. This aspect is particularly important in industries where sustainability and cost-effectiveness are paramount.

Another standout characteristic of the Desa CD32M is its robust security features. With integrated encryption and authentication protocols, it ensures that sensitive information is protected from unauthorized access and cyber threats. This level of security is essential for sectors like finance and healthcare, where data integrity and privacy are critical.

In addition to its hardware capabilities, the Desa CD32M is built for compatibility with a wide range of software platforms. This flexibility allows organizations to integrate the system into their existing workflows seamlessly. Its user-friendly interface also facilitates easier control and monitoring, making it accessible for users with varying levels of technical expertise.

Moreover, the scalability of the Desa CD32M sets it apart from conventional systems. Organizations can expand their operations and upgrade their capabilities without the need for a complete overhaul of their existing infrastructure. This scalability is particularly advantageous in today’s fast-paced business environment, where adaptability is crucial.

Overall, the Desa CD32M (-1)(-2) represents a significant advancement in digital systems technology. Its combination of processing power, energy efficiency, robust security, and scalability makes it an invaluable asset for organizations looking to enhance their operational efficiency while ensuring data protection. As industries continue to evolve, technologies like the Desa CD32M will play an essential role in shaping the future of digital communication and data management.