Desa CD32M (-1)(-2) installation manual Table of Contents, Introduction

Page 2

2

TABLE OF CONTENTS INTRODUCTION

Before You Begin

TABLE OF CONTENTS

 

INTRODUCTION

2

SELECTING LOCATION

3

PRE-INSTALLATION PREPARATION

3

INSTALLATION

6

BURNER FLAME ADJUSTMENT

11

OPERATING FIREPLACE

12

CONVERTING FIREPLACE FROM NATURAL GAS

 

TO PROPANE/LP GAS

13

TROUBLESHOOTING

15

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

16

SPECIFICATIONS

20

WIRING DIAGRAM

20

OWNER’S REGISTRATION FORM

21

ACCESSORY AND REPLACEMENT PARTS

23

INTRODUCTION

WARNING:This product contains and/orgenerates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

Models CD32M sereies, CD36M-A series and CD42M-A series are heat circulating gravity direct-vent fireplaces with sealed combus- tion chamber. These fireplaces use millivolt gas control valve and millivolt ignition system.

These fireplaces are convertible with the standard setup as natural gas. Conversion may be performed by the O.E.M. mobile home builder or by a qualified service person on-site. If you are uncertain as to what gas your unit is equipped for, please check the rating plate located inside of the appliance opening or consult your mobile home supplier or your local distributor of DESA/Vexar products.

NOTICE: Check local building codes for area require- ments before installing this appliance.

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instructions through completely.

This DESA/Vexar fireplace and its components are safe when in- stalled according to this installation manual and operated as recom- mended. Unless you use DESA/Vexar components designed and tested for this fireplace system, YOU MAY CAUSE A SAFETY

HAZARD!

The DESA/Vexar warranty will be voided by, and DESA/Vexar disclaims any responsibility for the following actions:

A)Modification to the fireplace, components, doors, blower, fans or vent system.

B)Use of any component part not manufactured or approved by DESA/Vexar in combination with a DESA/Vexar fire- place system.

Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installa- tion of all factory built fireplaces. This fireplace, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or the Canadian Electrical Code, CSA C22.1.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian Installation Code, CAN/CGA B149. This appliance com- plies with ANSI Z21.88-1998 and CSA 2.33-M98 as a VENTED GAS FIREPLACE HEATER.

For..com

111916-01C

Image 2
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Table of Contents IntroductionClearances to Combustibles PRE-INSTALLATION PreparationSelecting Location Mantel ClearancesVent Termination Clearances FramingMinimum Clearances for Vent Terminations Venting Installation InstallationVenting Installation Precautions GAS Supply Testing Electrical Hookup and Remote Receiver DiagramPilot Adjustment GAS Line HOOK-UPInstalling LOG SET Removing Glass PanelModel CD42M-A Series Face Extension for Model CD32M only Burner Flame AdjustmentDecorative Facing Operation Guidelines For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Converting Fireplace from Natural GAS to PROPANE/LP GASConverting Pilot Installing New Parts for Gas Control Valve Conversion Converting Control ValveTroubleshooting Observed Problem Possible Cause RemedyCD36M-A Series Illustrated Parts BreakdownModels CD32M Parts List Models CD32M CD36M-A SeriesModel CD42M-A Not a field replaceable part Specifications Wiring DiagramAccessory and Replacement Parts MillivoltNot a UPC

CD32M (-1)(-2) specifications

Desa CD32M (-1)(-2) is a cutting-edge technology designed to meet the demands of modern applications, particularly in the realm of telecommunications and data processing. This sophisticated dual-mode digital system offers versatility and efficiency, making it suitable for various industries including finance, healthcare, and manufacturing.

One of the main features of the Desa CD32M is its advanced processing capability. With a dual-core architecture, it can handle multiple tasks simultaneously, greatly enhancing performance in complex environments. This multi-threading capability allows for improved response times and higher productivity, which is critical for applications that require real-time data analysis and processing.

The Desa CD32M incorporates innovative technologies such as dynamic power management and adaptive processing algorithms. These technologies enable the system to efficiently allocate resources based on task priority, minimizing energy consumption without sacrificing performance. This aspect is particularly important in industries where sustainability and cost-effectiveness are paramount.

Another standout characteristic of the Desa CD32M is its robust security features. With integrated encryption and authentication protocols, it ensures that sensitive information is protected from unauthorized access and cyber threats. This level of security is essential for sectors like finance and healthcare, where data integrity and privacy are critical.

In addition to its hardware capabilities, the Desa CD32M is built for compatibility with a wide range of software platforms. This flexibility allows organizations to integrate the system into their existing workflows seamlessly. Its user-friendly interface also facilitates easier control and monitoring, making it accessible for users with varying levels of technical expertise.

Moreover, the scalability of the Desa CD32M sets it apart from conventional systems. Organizations can expand their operations and upgrade their capabilities without the need for a complete overhaul of their existing infrastructure. This scalability is particularly advantageous in today’s fast-paced business environment, where adaptability is crucial.

Overall, the Desa CD32M (-1)(-2) represents a significant advancement in digital systems technology. Its combination of processing power, energy efficiency, robust security, and scalability makes it an invaluable asset for organizations looking to enhance their operational efficiency while ensuring data protection. As industries continue to evolve, technologies like the Desa CD32M will play an essential role in shaping the future of digital communication and data management.