Desa CGFP28N Cleaning and Maintenance, Cleaning Burner Injector Holder and Pilot AIR Inlet Hole

Page 20

CGFP28N and CGFP28NT

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and cir- culating air passageways of fire- place clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fire- place may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 48).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 49). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 48 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet

Hole

Pilot Assembly

Figure 49 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 16, to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

20

103413

Image 20
Contents Unvented VENT-FREE Natural GAS Fireplace What to do if YOU Smell GASSafety Information Unvented VENT-FREE Natural GAS FireplaceProduct Identification Local Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationCheck GAS Type Installing GA3650T Blower Accessory For CGFP28P Model OnlyOperating the Blower Metal grounding screw provided seeFor CGFP28PT Model Only Attaching Speed Control to FireboxOperating the Blower As a freestanding unit with an acMinimum Wall and Ceiling Clearances see Figure Installation ClearancesConventional Fireplace Installation BUILT-IN Fireplace DepthInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Installing Logs Pressure Testing Fireplace Gas ConnectionsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceVariable Manually-Controlled Model CGFP28N Manual Lighting ProcedureThermostat Control Operation Inspecting Burners Variable Control OperationPilot Flame Pattern Front Burner Flame PatternLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Service Hints SpecificationsTechnical Service Parts CentralsReplacement Parts AccessoriesIllustrated Parts Breakdown Parts List KEY Part Number Description QTYLOG Base Assembly THERMOSTAT- Controlled Model CGFP28NT Parts List Fireplace CGFP28N CGFP28NT Fireplace CGFP28N CGFP28NTWarranty Information

CGFP28NT, CGFP28N specifications

The Desa CGFP28NT and CGFP28N are state-of-the-art gas fireplaces designed to enhance the ambiance and comfort of any living space. These models are recognized for their combination of aesthetic appeal and advanced technology, providing users with a reliable and efficient heating solution.

One of the main features of both the CGFP28NT and CGFP28N is their sleek design, which seamlessly integrates into various décor styles. Their clean lines and modern look allow them to serve as a focal point in the room while providing warmth and comfort. The large viewing windows offer an unobstructed view of the flames, creating an inviting atmosphere.

Technologically, both models are equipped with the latest innovations to ensure optimal performance. The CGFP28NT features an advanced electronic ignition system, which guarantees a quick and reliable start every time. This system minimizes gas usage and allows for consistent temperature control, making it both environmentally friendly and cost-effective.

The CGFP28N is designed with a unique heat exchanger that maximizes heat output while maintaining safety. This technology ensures that the fireplace operates efficiently, distributing warmth evenly throughout the room without overheating the unit itself. Additionally, both models incorporate a variable flame control feature, allowing users to adjust the intensity of the fire according to their needs.

Another key aspect of the CGFP28NT and CGFP28N is their user-friendly interface. Both models come with a remote control, enabling users to operate the fireplace from the comfort of their couch. This added convenience is paired with straightforward installation requirements, making it accessible for a wide range of customers.

Safety is a top priority for Desa, and these models feature an automatic shut-off valve that activates in case of any irregularities, ensuring peace of mind for homeowners. They also have a durable construction that withstands the test of time, making them a wise investment for those seeking a dependable heating source.

In summary, the Desa CGFP28NT and CGFP28N gas fireplaces offer a perfect blend of style, technology, and safety. With their eye-catching designs, advanced features, and user-friendly operation, they are an excellent choice for anyone looking to enhance their home with the warmth and beauty of a gas fireplace.