You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

PARTS CENTRALS

These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original re- placement parts and accessories.

Heater & Fireplace Store

1922 N Route 9

Cape May Court, NJ 08210-1110 609-624-0678

Parts Department

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

fireplace will backfire when lit

SPECIFICATIONS

Btu (Variable)

20,000/28,000

Type Gas

Natural Gas Only

Ignition

Piezo

Manifold Pressure

3.4" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

80 lbs.

(*For purpose of input adjustment)

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s Technical Service web site at www.desatech.com.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553

Parts Department

Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383-9704 All States

219-462-7441

1-800-362-6951 Parts Department

FBD

1349 Adams St.

Bowling Green, KY 42103-3414 502-846-1199

1-800-654-8534

Four Flags Power Products

1115 Stateline Road

Niles, MI 49120-4728 616-684-2697

1-800-268-4983 Parts Only

Master Parts Distributor 1251 Mound Ave. NW Grand Rapids , MI 49504-2672 616-791-0505

1-800-446-1446 Fax: 1-616-791-8270 Parts Department

Washer Equipment Co.

1715 Main Street

Kansas City, MO 64108-2195 KS, MO, AR

816-842-3911 Parts Department

East Coast Energy Products

707 Broadway

W. Long Branch, NJ 07764-1542 732-870-8809

1-800-755-8809 Parts Department

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728-6129 908-780-9340

1-800-922-0724 Parts Department

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States

937-258-3721

OH 1-800-762-3426 Parts Department

Halco Enterprises

208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717

1-800-368-0803 Parts Department

LaPorte’s Parts and Service 2444 North 5th Street Hartsville, SC 29550-7704 803-332-0191

Parts Department

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States

803-879-3009

1-800-845-5301 Parts Department

24

103413

Image 24
Contents Unvented VENT-FREE Natural GAS Fireplace What to do if YOU Smell GASSafety Information Unvented VENT-FREE Natural GAS FireplaceProduct Identification Local Codes UnpackingProduct Features AIR for Combustion and VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeElectrical Hookup Installing GA3650T Blower Accessory For CGFP28P Model OnlyOperating the Blower Metal grounding screw provided seeFor CGFP28PT Model Only Attaching Speed Control to FireboxOperating the Blower As a freestanding unit with an acInstallation Clearances Conventional Fireplace InstallationMinimum Wall and Ceiling Clearances see Figure BUILT-IN Fireplace DepthInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Pressure Testing Fireplace Gas ConnectionsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Thermostat Control OperationVariable Manually-Controlled Model CGFP28N Inspecting Burners Variable Control OperationPilot Flame Pattern Front Burner Flame PatternCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Service Hints SpecificationsTechnical Service Parts CentralsReplacement Parts AccessoriesIllustrated Parts Breakdown Parts List KEY Part Number Description QTYLOG Base Assembly THERMOSTAT- Controlled Model CGFP28NT Parts List Fireplace CGFP28N CGFP28NT Fireplace CGFP28N CGFP28NTWarranty Information

CGFP28NT, CGFP28N specifications

The Desa CGFP28NT and CGFP28N are state-of-the-art gas fireplaces designed to enhance the ambiance and comfort of any living space. These models are recognized for their combination of aesthetic appeal and advanced technology, providing users with a reliable and efficient heating solution.

One of the main features of both the CGFP28NT and CGFP28N is their sleek design, which seamlessly integrates into various décor styles. Their clean lines and modern look allow them to serve as a focal point in the room while providing warmth and comfort. The large viewing windows offer an unobstructed view of the flames, creating an inviting atmosphere.

Technologically, both models are equipped with the latest innovations to ensure optimal performance. The CGFP28NT features an advanced electronic ignition system, which guarantees a quick and reliable start every time. This system minimizes gas usage and allows for consistent temperature control, making it both environmentally friendly and cost-effective.

The CGFP28N is designed with a unique heat exchanger that maximizes heat output while maintaining safety. This technology ensures that the fireplace operates efficiently, distributing warmth evenly throughout the room without overheating the unit itself. Additionally, both models incorporate a variable flame control feature, allowing users to adjust the intensity of the fire according to their needs.

Another key aspect of the CGFP28NT and CGFP28N is their user-friendly interface. Both models come with a remote control, enabling users to operate the fireplace from the comfort of their couch. This added convenience is paired with straightforward installation requirements, making it accessible for a wide range of customers.

Safety is a top priority for Desa, and these models feature an automatic shut-off valve that activates in case of any irregularities, ensuring peace of mind for homeowners. They also have a durable construction that withstands the test of time, making them a wise investment for those seeking a dependable heating source.

In summary, the Desa CGFP28NT and CGFP28N gas fireplaces offer a perfect blend of style, technology, and safety. With their eye-catching designs, advanced features, and user-friendly operation, they are an excellent choice for anyone looking to enhance their home with the warmth and beauty of a gas fireplace.