Desa CGFP28NT installation manual Warranty Information

Page 32

WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

COMFORT GLOW VENT-FREE NATURAL GAS FIREPLACE

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive

P.O. Box 90004

Bowling Green, KY 42102-9004

www.desatech.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

103413-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

103413 01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev. C

 

 

 

 

 

 

NOT A UPC

 

 

 

 

 

 

03/99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 32
Contents Unvented VENT-FREE Natural GAS Fireplace What to do if YOU Smell GASSafety Information Unvented VENT-FREE Natural GAS FireplaceProduct Identification Local Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationCheck GAS Type Installing GA3650T Blower Accessory For CGFP28P Model OnlyOperating the Blower Metal grounding screw provided seeFor CGFP28PT Model Only Attaching Speed Control to FireboxOperating the Blower As a freestanding unit with an acMinimum Wall and Ceiling Clearances see Figure Installation ClearancesConventional Fireplace Installation BUILT-IN Fireplace DepthInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Installing Logs Pressure Testing Fireplace Gas ConnectionsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceVariable Manually-Controlled Model CGFP28N Manual Lighting ProcedureThermostat Control Operation Inspecting Burners Variable Control OperationPilot Flame Pattern Front Burner Flame PatternLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Service Hints SpecificationsTechnical Service Parts CentralsReplacement Parts AccessoriesIllustrated Parts Breakdown Parts List KEY Part Number Description QTYLOG Base Assembly THERMOSTAT- Controlled Model CGFP28NT Parts List Fireplace CGFP28N CGFP28NT Fireplace CGFP28N CGFP28NTWarranty Information

CGFP28NT, CGFP28N specifications

The Desa CGFP28NT and CGFP28N are state-of-the-art gas fireplaces designed to enhance the ambiance and comfort of any living space. These models are recognized for their combination of aesthetic appeal and advanced technology, providing users with a reliable and efficient heating solution.

One of the main features of both the CGFP28NT and CGFP28N is their sleek design, which seamlessly integrates into various décor styles. Their clean lines and modern look allow them to serve as a focal point in the room while providing warmth and comfort. The large viewing windows offer an unobstructed view of the flames, creating an inviting atmosphere.

Technologically, both models are equipped with the latest innovations to ensure optimal performance. The CGFP28NT features an advanced electronic ignition system, which guarantees a quick and reliable start every time. This system minimizes gas usage and allows for consistent temperature control, making it both environmentally friendly and cost-effective.

The CGFP28N is designed with a unique heat exchanger that maximizes heat output while maintaining safety. This technology ensures that the fireplace operates efficiently, distributing warmth evenly throughout the room without overheating the unit itself. Additionally, both models incorporate a variable flame control feature, allowing users to adjust the intensity of the fire according to their needs.

Another key aspect of the CGFP28NT and CGFP28N is their user-friendly interface. Both models come with a remote control, enabling users to operate the fireplace from the comfort of their couch. This added convenience is paired with straightforward installation requirements, making it accessible for a wide range of customers.

Safety is a top priority for Desa, and these models feature an automatic shut-off valve that activates in case of any irregularities, ensuring peace of mind for homeowners. They also have a durable construction that withstands the test of time, making them a wise investment for those seeking a dependable heating source.

In summary, the Desa CGFP28NT and CGFP28N gas fireplaces offer a perfect blend of style, technology, and safety. With their eye-catching designs, advanced features, and user-friendly operation, they are an excellent choice for anyone looking to enhance their home with the warmth and beauty of a gas fireplace.