Desa RN30C, CGN18C Operating Heater Inspecting Burner, Pilot Flame Pattern, Shutting Off Heater

Page 19

OPERATING HEATER

Continued

INSPECTING BURNER

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 

 

 

 

 

Shutting Off Heater

1.

Turn control knob clockwise Clockwise to the PILOT position.

2.

Press in control knob and turn clockwise Clockwise to the OFF position.

3.

Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1.

Turn control knob clockwise Clockwise to the PILOT position.

MANUAL LIGHTING PROCEDURE

1.Remove front panel (see Figure 5, page 11).

2.Follow steps 1 through 5 under Lighting Instructions, pages 17 and 18.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

5.Replace front panel.

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Pilot Burner

Thermocouple

Figure 17 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 18 - Incorrect Pilot Flame Pattern

Continued 19

101806

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Heater 16 3/ 4 RN30C CeilingFloor RightMethods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingGRH/OV 007G Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Flame Pattern AT High Position Burner Flame PatternIncorrect Flame Pattern AT High Position Cabinet Cleaning and Maintenance Trouble ShootingObserved Possible Problem Cause Remedy ODS/PILOT and BurnerTROUBLE- Shooting Maintenance,From Top Trouble ShootingObserved Possible Remedy Problem Cause Ing statement atService Hints Technical ServiceRN30C CGN18C Parts Under Warranty Replacement Parts CentralsParts Not Under Warranty Valve GA5010 AccessoriesFAN Kits GA3100A and GA3200T Manual ShutoffRN30C KEY Part Number Description QTY RN30C Parts ListCGN18C CGN18C Parts List Limited Warranty Comfort Glow VENT-FREE Heaters Warranty Information

CGN18C, RN30C specifications

Desa RN30C and CGN18C are two innovative and efficient models that embody the latest advancements in design and functionality, making them stand out in their respective markets.

The Desa RN30C is primarily recognized for its exceptional performance as a heating solution. With its sleek, modern design, it seamlessly integrates into various settings, whether residential or commercial. This model boasts a high-efficiency rating, ensuring that energy consumption is minimized while providing optimal heating. One of the main features of RN30C is its advanced thermostat control system, which allows users to maintain consistent temperatures effortlessly. Additionally, the RN30C is equipped with a safety shut-off feature that provides peace of mind while using the unit in different environments.

On the other hand, the CGN18C model is recognized for its versatility and capabilities in the realm of cooling systems. Like the RN30C, it features an attractive design, which enhances the aesthetic appeal of any space it occupies. The CGN18C comes with smart technology integration, allowing users to operate the cooling system remotely via smartphone applications. This level of convenience is a significant draw for tech-savvy consumers who prioritize efficiency and ease of use. Furthermore, the CGN18C is designed with energy-saving features, including a programmable timer and eco-mode, to minimize energy costs without sacrificing performance.

Both models incorporate cutting-edge technologies, such as inverter technology, which significantly reduces energy consumption while providing quick and consistent temperature adjustments. They are also compliant with current environmental standards, emphasizing eco-friendliness in their design and operation.

One of the most appealing characteristics of both the RN30C and CGN18C is their durability. Made from high-quality materials, they are built to withstand the test of time, ensuring long-term reliability. Consumers seeking modern heating and cooling solutions will find these models meet the demands of contemporary life, delivering performance, sustainability, and innovation.

In summary, Desa RN30C and CGN18C represent the pinnacle of efficiency and technological advancement, making them ideal choices for anyone looking to upgrade their heating and cooling systems. Their modern features and eco-friendly design showcase a commitment to quality and customer satisfaction that is hard to match.