Desa RN30C, CGN18C installation manual Ventilation AIR, Ventilation Air From Inside Building

Page 7

AIR FOR COMBUSTION AND VENTILATION

Continued

WARNING

WARNING ICON

G 001

If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

WARNING ICON

G 001

 

 

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

12"

Figure 2 - Ventilation Air from Inside Building

Continued

7

 

101806

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Heater 16 3/ 4 RN30C CeilingFloor RightMethods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingGRH/OV 007G Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Flame Pattern AT High Position Burner Flame PatternIncorrect Flame Pattern AT High Position Cabinet Cleaning and Maintenance Trouble ShootingObserved Possible Problem Cause Remedy ODS/PILOT and BurnerTROUBLE- Shooting Maintenance,From Top Trouble ShootingObserved Possible Remedy Problem Cause Ing statement atService Hints Technical ServiceRN30C CGN18C Parts Under Warranty Replacement Parts CentralsParts Not Under Warranty Valve GA5010 AccessoriesFAN Kits GA3100A and GA3200T Manual ShutoffRN30C KEY Part Number Description QTY RN30C Parts ListCGN18C CGN18C Parts List Limited Warranty Comfort Glow VENT-FREE Heaters Warranty Information

CGN18C, RN30C specifications

Desa RN30C and CGN18C are two innovative and efficient models that embody the latest advancements in design and functionality, making them stand out in their respective markets.

The Desa RN30C is primarily recognized for its exceptional performance as a heating solution. With its sleek, modern design, it seamlessly integrates into various settings, whether residential or commercial. This model boasts a high-efficiency rating, ensuring that energy consumption is minimized while providing optimal heating. One of the main features of RN30C is its advanced thermostat control system, which allows users to maintain consistent temperatures effortlessly. Additionally, the RN30C is equipped with a safety shut-off feature that provides peace of mind while using the unit in different environments.

On the other hand, the CGN18C model is recognized for its versatility and capabilities in the realm of cooling systems. Like the RN30C, it features an attractive design, which enhances the aesthetic appeal of any space it occupies. The CGN18C comes with smart technology integration, allowing users to operate the cooling system remotely via smartphone applications. This level of convenience is a significant draw for tech-savvy consumers who prioritize efficiency and ease of use. Furthermore, the CGN18C is designed with energy-saving features, including a programmable timer and eco-mode, to minimize energy costs without sacrificing performance.

Both models incorporate cutting-edge technologies, such as inverter technology, which significantly reduces energy consumption while providing quick and consistent temperature adjustments. They are also compliant with current environmental standards, emphasizing eco-friendliness in their design and operation.

One of the most appealing characteristics of both the RN30C and CGN18C is their durability. Made from high-quality materials, they are built to withstand the test of time, ensuring long-term reliability. Consumers seeking modern heating and cooling solutions will find these models meet the demands of contemporary life, delivering performance, sustainability, and innovation.

In summary, Desa RN30C and CGN18C represent the pinnacle of efficiency and technological advancement, making them ideal choices for anyone looking to upgrade their heating and cooling systems. Their modern features and eco-friendly design showcase a commitment to quality and customer satisfaction that is hard to match.