Desa CGN18C installation manual RN30C Parts List, KEY Part Number Description QTY

Page 29

RN30C

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

098304-01

Screw, #10 x 3/8"

2

2

098345-01AC

Front Panel

1

3

098197-04

Grill Guard

1

4

098342-01

Clip, Grill Guard

2

5

099001-01BR

Heat Shield

1

6

M11084-26

Screw, #10 x 3/8"

4

7

098352-02BR

Deflector Unit

1

8

098271-03

Ignitor Cable

1

9

098249-01

Nut, M5

2

10

099440-05

ODS/Pilot, N.G.

1

10-1

098514-01

Thermocouple

1

10-2

098594-01

Ignitor Electrode

1

11

099126-02

Burner

1

12

099387-05

3/16" Pilot Tubing

1

13

098251-06

Injector

1

14

098250-01

Injector Holder

1

15

098867-04

Pressure Regulator

1

16

099553-01

Pilot Shield

1

17

100091-01

3/8" Outlet (Burner) Tubing

1

18

100092-01

3/8" Inlet Tubing

1

19

100068-01

Pressure Tap Fitting

1

20

100047-01

Control Valve

1

21

098529-02

Cabinet

1

22

102445-01

Piezo Ignitor

1

23

M11084-26

Screw, #10 x 3/8"

2

24

M11084-38

Screw, #8 x 3/8"

2

25

098276-01

1/8" NPT Plug

1

26

098354-01

Control Knob

1

27

098508-01

Valve Retainer Nut

1

28

099066-01

Mounting Bracket

1

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

098306-02

099261-02

100642-01

Control Position Decal

Operating Instructions Decal

Assembly, Hardware

1

1

1

29

101806

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsLocating Heater Installation ItemsCheck GAS Type Floor CeilingRight 16 3/ 4 RN30CMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingGRH/OV 007G Pilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litIncorrect Flame Pattern AT High Position Burner Flame PatternCorrect Flame Pattern AT High Position Observed Possible Problem Cause Remedy Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetTROUBLE- Shooting Maintenance,From Observed Possible Remedy Problem Cause Trouble ShootingIng statement at TopRN30C CGN18C Technical ServiceService Hints Parts Not Under Warranty Replacement Parts CentralsParts Under Warranty FAN Kits GA3100A and GA3200T AccessoriesManual Shutoff Valve GA5010RN30C KEY Part Number Description QTY RN30C Parts ListCGN18C CGN18C Parts List Limited Warranty Comfort Glow VENT-FREE Heaters Warranty Information

CGN18C, RN30C specifications

Desa RN30C and CGN18C are two innovative and efficient models that embody the latest advancements in design and functionality, making them stand out in their respective markets.

The Desa RN30C is primarily recognized for its exceptional performance as a heating solution. With its sleek, modern design, it seamlessly integrates into various settings, whether residential or commercial. This model boasts a high-efficiency rating, ensuring that energy consumption is minimized while providing optimal heating. One of the main features of RN30C is its advanced thermostat control system, which allows users to maintain consistent temperatures effortlessly. Additionally, the RN30C is equipped with a safety shut-off feature that provides peace of mind while using the unit in different environments.

On the other hand, the CGN18C model is recognized for its versatility and capabilities in the realm of cooling systems. Like the RN30C, it features an attractive design, which enhances the aesthetic appeal of any space it occupies. The CGN18C comes with smart technology integration, allowing users to operate the cooling system remotely via smartphone applications. This level of convenience is a significant draw for tech-savvy consumers who prioritize efficiency and ease of use. Furthermore, the CGN18C is designed with energy-saving features, including a programmable timer and eco-mode, to minimize energy costs without sacrificing performance.

Both models incorporate cutting-edge technologies, such as inverter technology, which significantly reduces energy consumption while providing quick and consistent temperature adjustments. They are also compliant with current environmental standards, emphasizing eco-friendliness in their design and operation.

One of the most appealing characteristics of both the RN30C and CGN18C is their durability. Made from high-quality materials, they are built to withstand the test of time, ensuring long-term reliability. Consumers seeking modern heating and cooling solutions will find these models meet the demands of contemporary life, delivering performance, sustainability, and innovation.

In summary, Desa RN30C and CGN18C represent the pinnacle of efficiency and technological advancement, making them ideal choices for anyone looking to upgrade their heating and cooling systems. Their modern features and eco-friendly design showcase a commitment to quality and customer satisfaction that is hard to match.