Desa P325E(B), VP325E(B), VP324E Operating Fireplace, For Your Safety Read Before Lighting

Page 15

INSTALLATION

Installing Optional Glass Door Accessory (Cont.)

OPERATION

For Your Safety Read Before Lighting

Lighting Instructions

15

INSTALLATION

Continued

8.Close both doors until evenly joined at the middle and note the gap at the outer edges of the face.

9.Reopen one door at a time and retighten the upper and lower hold-down screws.

10.Repeat the process until both doors are evenly joined, spaced and working freely.

CAUTION: The glass panels become very hot while the appliance is operating. Do not attempt to adjust or clean the glass doors until the appliance has fully cooled.

Removing Glass Doors for Replacement or Cleaning

1.Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip.

2.Fully fold the frame assembly and slide the upper edge to- wards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 32).

CAUTION: Always operate the appliance with the doors either fully opened or fully closed. Operating the appliance with the doors partially open can result in improper venting of flue products.

Spring Clip

Hold-Down

 

 

Screw

Side Front

Face

Partially

Opened

Door

Figure 31 - Adjusting Glass Doors

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

 

Spring Clip

 

Depress Spring

 

Clip to Release

Fold Bi-Fold

Pivot Pin

 

Door After

 

Releasing

Remove Bottom

Spring Clip and

Slide Door Out

Pin From Pivot

of Upper Track

Plate While Sliding

 

Door Out of the

 

Upper Track

 

Pivot Plate

Figure 32 - Removing Glass Doors

 

1.STOP! Read the safety information, above.

2.Turn off all electric power to the appliance.

3.Turn wall switch to the OFF position.

4.Fully open glass doors if installed.

5.Remove front refractory brick access panel.

6. Turn equipment shutoff valve clockwise Clockwise to the OFF position (see Figure 33, page 16). Do not force.

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step.

8.Turn equipment shutoff valve counterclockwise C-clockwiseto the ON position. Do not force.

9.Replace front refractory brick access panel.

For more information, visit www.desatech.com

108794

Image 15
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking Before YOU Begin IntroductionSelecting Location Product SpecificationsPRE-INSTALLATION Preparation ClearancesMantel Clearances and Wall Details Framing Corner Installation GuidelinesTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingGAS Line HOOK-UP InstallationWall Switch Installation Optional Remote ControlOvertighten LOG Placement for P324E/VP324E Models Ember and PAN Material PlacementInstalling Log LOG Placement for P325EB/VP325EB ModlesInstalling Optional Glass Door Accessory Combustion AIR KIT Model AK4 OptionalAppliance Enclosure For Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To Appliance Pilot AssemblyInspecting Burners Optional Remote OperationLogs Cleaning MaintenanceBurner Flame Pattern Pilot and BurnerWiring Diagram Service HintsTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Accessories Illustrated Parts Breakdown P324E and VP324E Models Parts ListP325EB and VP325EB Models Illustrated Parts BREAKDOWN44108866-01 Pilot Natural Gas 901157-01 Lava Rock Illustrated Parts Breakdown LOG Assembly108794 Warranty Information

VP324E, P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B) specifications

Desa P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B), and VP324E are a series of advanced pumps designed to meet the diverse needs of industrial applications. These pumps are renowned for their efficiency, durability, and versatility, making them an ideal choice for various sectors such as manufacturing, chemical processing, and water management.

The main features of these pump models lie in their robust construction and innovative design. They are built using high-quality materials that ensure longevity and resistance to corrosive environments. The pumps also feature advanced sealing technologies that minimize leakage risks, thus enhancing operational safety and reliability.

One of the standout technologies in these models is their semi-open impeller design, which provides superior hydraulic performance. This design allows for handling solids and slurries effectively, making them suitable for applications where traditional pumps might struggle. The pumps also boast a user-friendly interface that simplifies operation and maintenance, reducing downtime and operational costs.

The Desa P324E and VP324E models are known for their compact size and high flow rate capabilities, making them suitable for space-constrained installations. In contrast, the P325E series, including the VP325E and its variants, offers enhanced performance specifications with improved energy efficiency. This is achieved through an innovative motor design that ensures lower energy consumption without compromising output.

The pumps are equipped with intelligent monitoring systems, allowing for real-time assessment of performance metrics. This feature enables predictive maintenance, significantly extending the lifespan of the equipment and minimizing unexpected failures. Additionally, the integration of advanced control systems allows users to customize operational parameters according to specific application needs.

Each model within the series can be tailored with various options, including different mounting configurations, motor types, and material finishes. This adaptability ensures that the pumps can be effectively integrated into existing systems and meet specific industry standards.

In summary, the Desa P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B), and VP324E series represent a culmination of engineering excellence, designed to address the demands of modern industrial applications. With their combination of advanced technology, robust design, and flexibility, these pumps offer reliable performance that can be counted on across a range of challenging environments.