SAFETY INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completelybeforetryingtoassemble,operate,orservice this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.A hearth extension is not required with this appliance. If one is installed, it is for aesthetic purposes only and does not have to meet the standard requirements.

For morevisit www..com

108794

Image 2
Contents Natural GAS For Your SafetyVent Decorative GAS Fireplace What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Introduction Before YOU BeginProduct Specifications Selecting LocationMantel Clearances and Wall Details PRE-INSTALLATION PreparationClearances Corner Installation Guidelines FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchOptional Remote Control InstallationWall Switch Installation GAS Line HOOK-UPOvertighten Ember and PAN Material Placement LOG Placement for P324E/VP324E ModelsLOG Placement for P325EB/VP325EB Modles Installing LogAppliance Enclosure Installing Optional Glass Door AccessoryCombustion AIR KIT Model AK4 Optional Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Pilot AssemblyInspecting Burners To Turn OFF GAS To AppliancePilot and Burner Cleaning MaintenanceBurner Flame Pattern LogsReplacement Parts Service HintsTechnical Service Wiring DiagramTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Accessories Illustrated Parts Breakdown Parts List P324E and VP324E ModelsIllustrated Parts BREAKDOWN44 P325EB and VP325EB Models108866-01 Pilot Natural Gas 901157-01 Lava Rock LOG Assembly Illustrated Parts Breakdown108794 Warranty Information

VP324E, P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B) specifications

Desa P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B), and VP324E are a series of advanced pumps designed to meet the diverse needs of industrial applications. These pumps are renowned for their efficiency, durability, and versatility, making them an ideal choice for various sectors such as manufacturing, chemical processing, and water management.

The main features of these pump models lie in their robust construction and innovative design. They are built using high-quality materials that ensure longevity and resistance to corrosive environments. The pumps also feature advanced sealing technologies that minimize leakage risks, thus enhancing operational safety and reliability.

One of the standout technologies in these models is their semi-open impeller design, which provides superior hydraulic performance. This design allows for handling solids and slurries effectively, making them suitable for applications where traditional pumps might struggle. The pumps also boast a user-friendly interface that simplifies operation and maintenance, reducing downtime and operational costs.

The Desa P324E and VP324E models are known for their compact size and high flow rate capabilities, making them suitable for space-constrained installations. In contrast, the P325E series, including the VP325E and its variants, offers enhanced performance specifications with improved energy efficiency. This is achieved through an innovative motor design that ensures lower energy consumption without compromising output.

The pumps are equipped with intelligent monitoring systems, allowing for real-time assessment of performance metrics. This feature enables predictive maintenance, significantly extending the lifespan of the equipment and minimizing unexpected failures. Additionally, the integration of advanced control systems allows users to customize operational parameters according to specific application needs.

Each model within the series can be tailored with various options, including different mounting configurations, motor types, and material finishes. This adaptability ensures that the pumps can be effectively integrated into existing systems and meet specific industry standards.

In summary, the Desa P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B), and VP324E series represent a culmination of engineering excellence, designed to address the demands of modern industrial applications. With their combination of advanced technology, robust design, and flexibility, these pumps offer reliable performance that can be counted on across a range of challenging environments.