Desa MVO24VPA, MVO18VPA Check GAS Type, Installation and Clearances, Flue Opening Specifications

Page 6

INSTALLATION

Continued

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not instal in fireplace. Call dealer where you bought the appliance for proper type of appliance.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES

Figure 2 shows technical information regarding the installation of your gas log set. Please make sure all specifications shown are applicable before installation is attempted.

 

SPECIFICATIONS (W.C.)

 

FUEL INLET

MANIFOLD

 

PRESSURE

PRESSURE

 

Min.

Max.

 

NG

7"

10.5"

3.5"

LP

11"

14"

10"

Figure 2 - Technical Information Chart

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only

in a solid-fuel burning or UL127 factory-built fire-

place constructed of noncombustible material and

connected to a working flue. The fireplace chimney

must have a permanent vent opening to outside

with minimum openings shown in Figure 3.

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

 

MINIMUM FIREBOX SIZE

 

LOG

 

 

 

FRONT REAR* MIN. FLUE

SIZE HEIGHT DEPTH WIDTH WIDTH

SIZE

18"

20"

14"

25"

20.5"

6.5"

24"

20"

14"

29"

24.5"

6.5"

*Measured at 14" depth

 

 

 

 

Figure 3 - Sizes and Clearances

VENTING SPECIFICATIONS FOR

INSTALLATION

 

 

 

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of the fireplace.

Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue damper must be fixed open to pro- vide a minimum of 32 square inch of free air opening at all times during operation of the log set. A damper clamp is included to secure the damper.

The minimum flue sizes shown in Figure 3 are based on a 6' chimney height using round pipe. Your minimum flue size will vary based on input rate and chimney height. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 6.6 for details.

INSTALLING DAMPER CLAMP

Secure the damper stop clam to the edge of the

damper as shown in Figure 4. If for any reason

this clamp doesn't work on your fireplace, another

suitable clamp or permanent stop must be installed,

or the damper blade must be cut or removed.

Damper

 

Clamp

Damper

 

Damper

 

Clamp

 

Damper

Damper

Masonry

Manufactured

Fireplace

Fireplace

Figure 4 - Attaching Damper Clamp

INSTALLING REMOTE CONTROL

ACCESSORY BRACKET

If installing optional remote control accessory you

will need to install the remote accessory bracket

for the receiver.

 

Use screws provided to attach bracket to valve

bracket as shown in Figure 5.

Follow installation instructions included with

remote accessory.

 

Valve Bracket

 

Remote

 

Bracket

 

Figure 5 - Attaching Remote Bracket to

Valve Bracket

6

www.desatech.com

114924-01B

Image 6
Contents What to do if YOU Smell GAS MVO24VNA, MVO24VPA MVO18VNA and MVO18VPATable of Contents Safety Information Local Codes High traffic areas Windy or drafty areasProvide adequate clearances around air openings Remove log set assembly from carton Product FeaturesInstallation Product IdentificationVenting Specifications for Installation and ClearancesFlue Opening Specifications InstallationInstalling Appliance Connecting to GAS SupplyInstallation Items Needed Propane/LP Checking GAS ConnectionsNatural Test Pressures In Excess Of 1/2 PsigPlacement of Loose Embers Pressure Testing Appliance Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before Lighting Operating ApplianceLighting Instructions To Turn OFF GAS To Appliance Wiring DiagramWhen Using Remote Optional HAND-HELD Remote OperationPilot Flame Pattern Cleaning MaintenanceInspecting Burners Check pilot flame pattern and burner flame pat- terns oftenTroubleshooting Observed Problem Possible Cause RemedyReplace burner orifices Contact local natural orPilot is lit Burner orifices clogged Propane/LP gas company Replace burner orificeTurn control knob to LO Burners are lit Position when burners areOperation Processes and log curing Hours of operation Cold Minute Air is gas line Operate burners until air isGas leak. See Warning Statement at topGas leak. See Warning statement at top Accessories Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown MVO24VNA, MVO24VPA MVO18VNA, MVO18VPAParts List Warranty Information Keep this WarrantyLimited Warranty Vented GAS LOG Appliances

MVO24VPA, MVO18VNA, MVO18VPA, MVO24VNA specifications

Desa MVO18VPA, MVO24VPA, MVO18VNA, and MVO24VNA represent a line of versatile and efficient heating solutions designed for various residential and commercial applications. These models are tailored to meet diverse user requirements while providing exceptional value through advanced technologies and features.

At the core of the Desa line is the commitment to energy efficiency. The MVO series incorporates high-efficiency motors and advanced heat exchange systems that ensure optimal performance while minimizing energy consumption. This not only leads to cost savings on utility bills but also reflects a commitment to sustainability, making these models an excellent choice for eco-conscious consumers.

In terms of heating capacity, the MVO18 models offer a robust output suitable for medium-sized spaces, while the MVO24 models are designed for larger areas, providing flexibility for different applications. The ability to adjust heating levels allows users to customize their environment according to their specific needs, enhancing comfort.

The MVO series is equipped with innovative technologies that ensure consistent performance. The integration of intelligent temperature controls provides precise management of heating levels, enabling users to maintain their desired comfort without unnecessary energy expenditure. Additionally, these models feature durable construction materials that ensure longevity and reliable operation over time.

User convenience is a significant consideration in the design of the MVO series. Remote control functionality allows users to effortlessly adjust settings from a distance, adding a layer of convenience for those with busy lifestyles. Furthermore, some models are equipped with programmable timers, enabling users to set specific heating schedules that align with their daily routines.

Safety is paramount in the design of the Desa MVO series. These models come with multiple safety features, including overheat protection and automatic shut-off mechanisms, ensuring peace of mind for users.

In summary, the Desa MVO18VPA, MVO24VPA, MVO18VNA, and MVO24VNA heating models stand out for their energy efficiency, advanced heating technologies, and user-friendly features. Their adaptability makes them suitable for a range of environments, catering to the diverse needs of homeowners and businesses alike. With a focus on safety and reliability, the Desa MVO series represents an excellent investment for those seeking effective heating solutions.