Desa VM36E, VM42E Selecting Location, PRE-INSTALLATION Preparation, Clearances

Page 6

6

SELECTING LOCATION PRE-INSTALLATION PREPARATION

Clearances

SELECTING LOCATION

To determine the safest and most efficient location for your appli- ance, you must take into consideration the following guidelines:

1.The location must allow for proper clearances (see Clearances, next column).

2.Consider a location where heat output would not be affected by drafts, air conditioning ducts, windows, or doors.

3.A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a plan view of a few common locations.

Flush installations are recommended where living space is limited or at a premium, and since the space required to enclose the appliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters, and such. Check local codes for any restrictions.

PRE-INSTALLATION

PREPARATION

CLEARANCES

Minimum clearances to combustibles are:

 

Back and Sides of Outer Surround

0" min.

Drywall to Sides of Front Face (Nailing Flanges) ... 0" min.

“B” Vent Surfaces

1" min.

Ceiling to Opening

42" min.

Floor

0" min.

Perpendicular Wall

See Figure 6, page 7

CAUTION: Do not block required air spaces with insulation or any other material. Do not obstruct effective opening of appliance with any type of facing material.

Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.

Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat

Back

2 x 4 Stud

Nailing

Flange

transference.

Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.

0" Clearance

Left Side

Surround

0"

 

CORNER

 

INTERNAL WALL

INSTALLATION

Drywall

INSTALLATION

Front Face

 

 

Figure 3 - Minimum Clearances (Top View)

FULL

FLUSH

Ceiling

INSTALLATION

 

PROJECTION

 

 

42" (1067mm)

INSTALLATION

 

 

Min. Clearance

 

 

from Opening to

 

 

Ceiling

 

 

0" Clearance

1" (25mm) Min.

Clearance to

"B" Vent’s Outer Pipe

Maintain 2" (51mm) Min.

Clearance to the Transition

Pipe as Measured at the

Outer Vent Collar

*

Figure 2 - Possible Locations for Installing Appliance

0" Clearance to Wood or Noncombustible Flooring

* *

DO NOT BLOCK OR OBSTRUCT OPENINGS

*Required Air Spaces are Indicated with

an "*". Do Not Pack with Insulation or Any Other Material

Figure 4 - Minimum Clearances (Front View)

For morevisit www..com

108796

Image 6
Contents Electronic Ignition Natural GAS For Your SafetyVent Decorative GAS Fireplace What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Introduction Before YOU BeginM36EB,H/VM36EB,H M42EB,H/VM42EB,H Product Specifications ModelPRE-INSTALLATION Preparation Selecting LocationClearances VM36EB,H VM42EB,H Mantel Clearances and Wall DetailsM36EB,H M42EB,H M36EB,H M42EB,H VM36EB,H VM42EB,HInstalling Transition Pipe and Starter Collar FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchOptional Remote Control InstallationWall Switch Installation GAS Line HOOK-UPEmber and PAN Material Placement OvertightenLOG Placement for M36E/VM36E Models Installing Logs 1LOG Placement for M42E/VM42E Models Installing Logs 1A, 1BInstalling Optional Glass Door Accessory Combustion AIR KIT Model AK4 OptionalAppliance Enclosure Opening Vent Damper DoorLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To ApplianceCleaning Maintenance Inspecting BurnersReplacement Parts Service HintsTechnical Service Wiring DiagramTroubleshooting Observed Problem Possible Cause RemedyTop Gas leak. See Warning statement atIllustrated Parts Breakdown VM42EB,H ModelsParts List M36EB,H,M42EB,H, VM36EB,H and VM42EB,H ModelsLogs for M36EB,H,M42EB,H, VM36EB,H and VM42EB,H Models Logset for M36EB,H and VM36EB,H ModelsAccessories Warranty Information