INSTALLATION

Installing Optional Glass Door Accessory (Cont.) Opening Vent Damper

INSTALLATION

Continued

5.Once the top and bottom pins are secured, unfold the door into the closed position.

6.Repeat the process for the opposite door assembly.

7.To adjust the doors, slide them partially open. Using a screw- driver, loosen the hold-down screws in the spring clip (see Fig- ure 34) and pivot plate.

8.Close both doors until evenly joined at the middle and note the gap at the outer edges of the face.

9.Reopen one door at a time and retighten the upper and lower hold-down screws.

10.Repeat the process until both doors are evenly joined, spaced and working freely.

CAUTION: The glass panels become very hot while the appliance is operating. Do not attempt to adjust or clean the glass doors until the appliance has fully cooled.

The doors may be removed for replacement or cleaning as follows:

1.Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip.

2.Fully fold the frame assembly and slide the upper edge to- wards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 35).

CAUTION: Always operate the appliance with the doors either fully opened or fully closed. Operating the appliance with the doors partially open can result in improper venting of flue products.

 

Spring Clip

 

Depress Spring

 

Clip to Release

 

Pivot Pin

Fold Bi-Fold

 

Door After

 

Releasing

Remove

Spring Clip and

Bottom Pin

Slide Door Out

From Pivot

of Upper Track

Plate While

 

Sliding Door

 

Out of the

 

Upper Track

 

Pivot Plate

Figure 35 - Removing Glass Doors

 

OPENING VENT DAMPER

Vent damper must be locked in the full open position before operating the fireplace. If vent damper is not open, fireplace will not light.

Spring Clip

 

VENT DAMPER MUST BE LOCKED

 

 

IN THE FULL OPEN POSITION

 

OPEN

TO OPERATE THE APPLIANCE

CLOSE

 

Side Front Face

Hold-Down Screw

Partially

Figure 36 - Opening Vent Damper

Opened

Door

 

Figure 34 - Adjusting Glass Doors

 

For morevisit www..com

108796

Image 16
Contents For Your Safety Vent Decorative GAS FireplaceElectronic Ignition Natural GAS What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Before YOU Begin IntroductionM36EB,H/VM36EB,H M42EB,H/VM42EB,H Product Specifications ModelSelecting Location PRE-INSTALLATION PreparationClearances Mantel Clearances and Wall Details M36EB,H M42EB,HVM36EB,H VM42EB,H M36EB,H M42EB,H VM36EB,H VM42EB,HInstalling Transition Pipe and Starter Collar FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchInstallation Wall Switch InstallationOptional Remote Control GAS Line HOOK-UPEmber and PAN Material Placement OvertightenLOG Placement for M36E/VM36E Models Installing Logs 1LOG Placement for M42E/VM42E Models Installing Logs 1A, 1BCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Opening Vent Damper DoorFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceCleaning Maintenance Inspecting BurnersService Hints Technical ServiceReplacement Parts Wiring DiagramTroubleshooting Observed Problem Possible Cause RemedyTop Gas leak. See Warning statement atIllustrated Parts Breakdown VM42EB,H ModelsParts List M36EB,H,M42EB,H, VM36EB,H and VM42EB,H ModelsLogs for M36EB,H,M42EB,H, VM36EB,H and VM42EB,H Models Logset for M36EB,H and VM36EB,H ModelsAccessories Warranty Information