Desa VDDVF36STN/STP, VDDVF36PN/PP installation manual Vent Opening Requirements

Page 11

VENTING INSTALLATION

Installation For Horizontal Termination (Cont.)

11

VENTING INSTALLATION

Continued

ing statement on page 9.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 16. Note: Hori- zontal runs of vent must be supported every three feet. Use wall straps for this purpose.

Flexible vent pipe must be installed with spacer springs every 12" (30.5cm). See Figure 16, page 10. All connections must be clamped tightly and sealed with high temperature silicone seal- ant as specified in the second warning statement on page 9.

3.Attach vent pipe assembly to the fireplace. Set fireplace in front of it’s permanent location to insure minimum clearances. Mark the wall for a 10" square hole (for noncombustible ma- terial such as masonry block or concrete, a 7 1/2" (19.1cm) diameter hole is acceptable). See Figure 17. The center of the hole should line up with the center-line of the horizontal rigid vent pipe. Cut a 10"x10" (25.4cm x 25.4cm) square hole through combustible exterior wall (7 1/2" [19.1cm] diameter hole if noncombustible). Frame as necessary (see Figure 17).

4.Noncombustible Exterior Wall: Apply a bead of non-harden- ing mastic around the outside edge of the vent cap. Position the vent cap in the center of the 7 1/2" (19.1cm) hole on the exterior wall with the arrow on the vent cap pointing up. Attach the vent cap with four wood screws provided (see Figure 18). Note: Re- place the wood screws with appropriate fasteners for stucco, brick, concrete, or other types of siding.

WARNING: Do not recess vent termination in to any wall. This will cause a fire hazard.

Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff must be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging siding materials. Siding materials must be cut to accommodate standoff. Bolt the vent cap to the stand- off. Apply non-hardening mastic around outside edge of the standoff. Position the standoff/cap assembly in the center of the 10" (25.4cm)square hole and attach to exterior wall with wood screws provided (see Figure 19). The siding standoff must sit flush against the exterior fascia material.

5.Combustible Exterior Wall Only: Slide the interior wall firestop over the vent pipe before connecting the horizontal run to the vent cap (see Figure 20).

6.Carefully move the fireplace with vent assembly attached to- ward the wall and insert the vent pipe into the horizontal termi- nation. The pipe overlap should be a minimum of 1 1/4" (3.2cm). Fasten all vent pipe connections (except vent cap) with screws provided. Refer to Framing on pages 5 and 6 for instructions on securing unit to framing or floor.

7.Combustible Exterior Wall Only: Slide the wall firestop against the interior wall surface and attach with screws pro- vided (see Figure 20).

Cut Vinyl Siding

Away to Fit Standoff

Standoff

Wood Screw

Apply Mastic

to All Four Sides

Vent Cap

Bolt

Figure 17 - Vent Opening Requirements

Vent Cap

Wood Screw

Figure 18 - Installing Horizontal Vent Cap

Figure 19 - Installing Vinyl Siding Standoff (Combustible Exterior Wall)

Interior Wall

Surface

Interior Wall Firestop (Combustible Exterior Wall Only)

 

Horizontal

 

Vent Pipe

Vent Cap

Screw

(Horizontal

 

Termination)

 

Figure 20 - Connecting Vent Cap with Horizontal Vent Pipe

For morevisit www..com

106918-01B

Image 11
Contents Save this Book Check Local Codes Prior to InstallationWhat to do if YOU Smell GAS Product Dimensions Table of ContentsIntroduction Firebox DimensionsGlossary of Terms Hazard Selecting LocationBefore YOU Begin Framing PRE-INSTALLATION PreparationClearances Mantel ClearancesRough Opening for Installing Peninsula Fireplace on Platform Location of Vent Termination General VentingGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Termination Configurations Installation for Vertical TerminationCathedral Ceiling Installation Flat Ceiling InstallationInstalled Cathedral Ceiling Support Box Vertical Termination ConfigurationsDesa International Elbows High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Rigid VentingDesa International Venting Accessories InstallationWall Switch Installation Electrical Hookup for Blower AccessoryInstalling Battery in Hand-Held Remote Control Unit Installing ReceiverGAS Rating Type of GAS Natural PROPANE/LP GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingDecorative Facing Pilot Assembly AdjustmentBurner Flame Adjustment Glass Door Panels Operating Guidelines and Maintenance InstructionsCleaning Maintenance Burner RemovalCleaning Operating Fireplace Maintenance Optional Remote Operation To Turn OFF GAS To ApplianceObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Company Gas leak. See Warning statement Technical Service Wiring DiagramAccessories Service HintsReplacement Parts List Replacement PartsBlack 105904-01 Refractory PiecesGAS Control Valve Natural 104496-01 14389 Propane/LP 104496-02Owners Registration Form Postage Required 106918-01B Keep this Warranty Warranty Information

VDDVF36PN/PP, VDDVF36STN/STP specifications

The Desa VDDVF36STN/STP and VDDVF36PN/PP represent a range of advanced heating solutions designed to meet modern demands for efficiency, comfort, and versatility. These models are distinguished by their exceptional features and cutting-edge technologies, making them suitable choices for both residential and commercial applications.

One of the primary features of the Desa VDDVF series is its innovative design that prioritizes energy efficiency. Designed with high-performance materials, these units are equipped to reduce energy consumption while providing powerful heating output. This ensures that users can enjoy a warm and comfortable environment without incurring excessive energy costs.

The VDDVF series utilizes advanced variable-speed technology, allowing for precise temperature control. This technology not only enhances comfort but also contributes to quieter operation, allowing users to enjoy a serene atmosphere. The variable-speed blower ensures that warm air is distributed evenly throughout the room, mitigating cold spots and maximizing comfort.

Another notable characteristic of the Desa VDDVF36 models is their adaptability. With options for either natural gas or propane, these heaters can meet a variety of user preferences and installation requirements. This flexibility makes them suitable for different environments, from cozy family homes to larger commercial spaces.

Safety is a priority in the design of the VDDVF series. Each unit is equipped with a range of safety features, including a built-in oxygen depletion sensor, which automatically shuts off the heater if oxygen levels drop to unsafe levels. This feature, along with a robust construction, ensures peace of mind for users.

In terms of aesthetics, the VDDVF36STN/STP and VDDVF36PN/PP boast a sleek and modern appearance that can enhance any interior decor. With customizable options, users can select finishes and styles that complement their space.

Overall, the Desa VDDVF36STN/STP and VDDVF36PN/PP epitomize the convergence of comfort, efficiency, and safety. Their advanced technologies and user-friendly features make these heating solutions an excellent investment for anyone seeking reliable warmth in their living or working environment. As energy efficiency continues to be a focal point in today’s world, the Desa VDDVF series stands out as a leading choice for those looking to balance performance with sustainability.