Desa VDDVF36PN/PP, VDDVF36STN/STP installation manual Company

Page 26

26

TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads

 

 

properly connected

 

 

 

4.

Thermopile is defective

4.

Replace thermopile

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

company

 

2.

Burner porting or orifice clogged

2.

Clean burner or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Fireplace produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP gas company

 

3.

Dirty or partially clogged burner orifice

3.

Clean burner or replace burner orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

not excessively impinge on it

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common. If noise is excessive, contact qualified service person

For..com

106918-01B

Image 26
Contents Save this Book Check Local Codes Prior to InstallationWhat to do if YOU Smell GAS Table of Contents Product DimensionsIntroduction Firebox DimensionsGlossary of Terms Hazard Selecting LocationBefore YOU Begin Mantel Clearances PRE-INSTALLATION PreparationClearances FramingRough Opening for Installing Peninsula Fireplace on Platform General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installation for Horizontal Termination Installing Vent System in a ChaseVent Opening Requirements Installation for Vertical Termination Horizontal Termination ConfigurationsFlat Ceiling Installation Cathedral Ceiling InstallationVertical Termination Configurations Installed Cathedral Ceiling Support BoxVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Desa International ElbowsElectrical Hookup for Blower Accessory InstallationWall Switch Installation Desa International Venting AccessoriesInstalling Receiver Installing Battery in Hand-Held Remote Control UnitGAS Line HOOK-UP GAS Rating Type of GAS Natural PROPANE/LPGAS Supply Testing Installing LOG SETDecorative Facing Pilot Assembly AdjustmentBurner Flame Adjustment Burner Removal Operating Guidelines and Maintenance InstructionsCleaning Maintenance Glass Door PanelsCleaning Operating Fireplace Maintenance To Turn OFF GAS To Appliance Optional Remote OperationTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Company Gas leak. See Warning statement Service Hints Wiring DiagramAccessories Technical ServiceReplacement Parts Replacement Parts ListNatural 104496-01 14389 Propane/LP 104496-02 Refractory PiecesGAS Control Valve Black 105904-01Owners Registration Form Postage Required 106918-01B Warranty Information Keep this Warranty

VDDVF36PN/PP, VDDVF36STN/STP specifications

The Desa VDDVF36STN/STP and VDDVF36PN/PP represent a range of advanced heating solutions designed to meet modern demands for efficiency, comfort, and versatility. These models are distinguished by their exceptional features and cutting-edge technologies, making them suitable choices for both residential and commercial applications.

One of the primary features of the Desa VDDVF series is its innovative design that prioritizes energy efficiency. Designed with high-performance materials, these units are equipped to reduce energy consumption while providing powerful heating output. This ensures that users can enjoy a warm and comfortable environment without incurring excessive energy costs.

The VDDVF series utilizes advanced variable-speed technology, allowing for precise temperature control. This technology not only enhances comfort but also contributes to quieter operation, allowing users to enjoy a serene atmosphere. The variable-speed blower ensures that warm air is distributed evenly throughout the room, mitigating cold spots and maximizing comfort.

Another notable characteristic of the Desa VDDVF36 models is their adaptability. With options for either natural gas or propane, these heaters can meet a variety of user preferences and installation requirements. This flexibility makes them suitable for different environments, from cozy family homes to larger commercial spaces.

Safety is a priority in the design of the VDDVF series. Each unit is equipped with a range of safety features, including a built-in oxygen depletion sensor, which automatically shuts off the heater if oxygen levels drop to unsafe levels. This feature, along with a robust construction, ensures peace of mind for users.

In terms of aesthetics, the VDDVF36STN/STP and VDDVF36PN/PP boast a sleek and modern appearance that can enhance any interior decor. With customizable options, users can select finishes and styles that complement their space.

Overall, the Desa VDDVF36STN/STP and VDDVF36PN/PP epitomize the convergence of comfort, efficiency, and safety. Their advanced technologies and user-friendly features make these heating solutions an excellent investment for anyone seeking reliable warmth in their living or working environment. As energy efficiency continues to be a focal point in today’s world, the Desa VDDVF series stands out as a leading choice for those looking to balance performance with sustainability.