Desa VDDVF36PN/PP Installation for Horizontal Termination, Installing Vent System in a Chase

Page 10

10

VENTING INSTALLATION

Installation Planning (Cont.) Installation For Horizontal Termination

VENTING INSTALLATION

Continued

Installing Vent System in a Chase

A chase is a vertical boxlike structure built to enclose venting that runs along the outside of a building. A chase is not required for such venting.

NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must fol- low all local building codes.

Note: When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Minimum clearance between vent pipes and combustible materials such as insulation is 1" (2.5cm).

After framing the chase (see Framing on pages 5 and 6) install the vent system by following the installation instructions.

INSTALLATION FOR HORIZONTAL TERMINATION

CAUTION: Horizontally terminated venting con- figurations require one foot of vertical rise from the 45° elbow before any horizontal run can be made. Failure to meet venting requirements may cause performance problems and possible damage to the fireplace.

1.Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be blocked or obstructed.

WARNING: Do not recess vent terminal into a wall or siding.

Snorkel terminations are available for terminations requiring a vertical rise on the exterior of the building (see Figures 14 and 15). Snorkel kit SVK is also available (see page 15). Follow the same installation procedures used for standard horizontal termi- nations. If installing the snorkel termination below grade (base- ment applications), you must provide proper drainage to pre- vent water from entering the snorkel termination (see Figure 15). Do not back fill around the snorkel termination.

2.Rigid vent pipes and fittings have special twist-lock connections. Assemble the desired combination of pipe and elbows to the ap- pliance adaptor with pipe seams oriented towards the wall or floor.

Twist-lock Procedure: The female ends of the pipes and fit- tings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fittings. (All connections must be sealed with high temperature silicone sealant as specified in the second warn-

Snorkel

90º

1' Minimum

12" Minimum

45º

Figure 14 - Snorkel Termination

Snorkel

90º

1' Minimum

12" Minimum

 

45°

Adequate

Drainage

Figure 15 - Snorkel Termination with Drainage Pipe

Female

Spacer

4" Clamp

 

Locking Lugs

Spring

7" Clamp

 

 

4" Flex

 

 

Pipe

Male Slots

 

7" Flex

 

Pipe

 

 

Rigid Vent Pipe

Flexible Vent Pipe

Figure 16 - Vent Pipe Connections

For..com

106918-01B

Image 10
Contents What to do if YOU Smell GAS Check Local Codes Prior to InstallationSave this Book Table of Contents Product DimensionsGlossary of Terms Firebox DimensionsIntroduction Before YOU Begin Selecting LocationHazard Mantel Clearances PRE-INSTALLATION PreparationClearances FramingRough Opening for Installing Peninsula Fireplace on Platform General Venting Location of Vent TerminationGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installation for Horizontal Termination Installing Vent System in a ChaseVent Opening Requirements Installation for Vertical Termination Horizontal Termination ConfigurationsFlat Ceiling Installation Cathedral Ceiling InstallationVertical Termination Configurations Installed Cathedral Ceiling Support BoxVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Desa International ElbowsElectrical Hookup for Blower Accessory InstallationWall Switch Installation Desa International Venting AccessoriesInstalling Receiver Installing Battery in Hand-Held Remote Control UnitGAS Line HOOK-UP GAS Rating Type of GAS Natural PROPANE/LPGAS Supply Testing Installing LOG SETBurner Flame Adjustment Pilot Assembly AdjustmentDecorative Facing Burner Removal Operating Guidelines and Maintenance InstructionsCleaning Maintenance Glass Door PanelsCleaning Operating Fireplace Maintenance To Turn OFF GAS To Appliance Optional Remote OperationTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Company Gas leak. See Warning statement Service Hints Wiring DiagramAccessories Technical ServiceReplacement Parts Replacement Parts ListNatural 104496-01 14389 Propane/LP 104496-02 Refractory PiecesGAS Control Valve Black 105904-01Owners Registration Form Postage Required 106918-01B Warranty Information Keep this Warranty

VDDVF36PN/PP, VDDVF36STN/STP specifications

The Desa VDDVF36STN/STP and VDDVF36PN/PP represent a range of advanced heating solutions designed to meet modern demands for efficiency, comfort, and versatility. These models are distinguished by their exceptional features and cutting-edge technologies, making them suitable choices for both residential and commercial applications.

One of the primary features of the Desa VDDVF series is its innovative design that prioritizes energy efficiency. Designed with high-performance materials, these units are equipped to reduce energy consumption while providing powerful heating output. This ensures that users can enjoy a warm and comfortable environment without incurring excessive energy costs.

The VDDVF series utilizes advanced variable-speed technology, allowing for precise temperature control. This technology not only enhances comfort but also contributes to quieter operation, allowing users to enjoy a serene atmosphere. The variable-speed blower ensures that warm air is distributed evenly throughout the room, mitigating cold spots and maximizing comfort.

Another notable characteristic of the Desa VDDVF36 models is their adaptability. With options for either natural gas or propane, these heaters can meet a variety of user preferences and installation requirements. This flexibility makes them suitable for different environments, from cozy family homes to larger commercial spaces.

Safety is a priority in the design of the VDDVF series. Each unit is equipped with a range of safety features, including a built-in oxygen depletion sensor, which automatically shuts off the heater if oxygen levels drop to unsafe levels. This feature, along with a robust construction, ensures peace of mind for users.

In terms of aesthetics, the VDDVF36STN/STP and VDDVF36PN/PP boast a sleek and modern appearance that can enhance any interior decor. With customizable options, users can select finishes and styles that complement their space.

Overall, the Desa VDDVF36STN/STP and VDDVF36PN/PP epitomize the convergence of comfort, efficiency, and safety. Their advanced technologies and user-friendly features make these heating solutions an excellent investment for anyone seeking reliable warmth in their living or working environment. As energy efficiency continues to be a focal point in today’s world, the Desa VDDVF series stands out as a leading choice for those looking to balance performance with sustainability.